Products:
CE4914091 generator governor slow start controller for PT (G) type fuel system for Cummins N, K series diesel generator sets. Module housing is 150mm X 105mm X 40mm aluminum parts, the surface spray. Epoxy potting. CE4914091 for normally closed unit 800KW or less. The same type of 4,914,090 units for normally closed 350KW or less.
Product performance and features:
1, reduce smoke, conducive to boot
2, strong against external interference, to maintain stable operation of the unit
3, the actuator short protection, extended service life.
4, an increase of smooth slow start process control, this new feature can solve the phenomenon of black smoke from the engine during start-up caused by the rapid refueling, reducing startup noise, engine speed up the time in 0 seconds, 5 seconds, 10 seconds , 15 seconds, 20 seconds, 25 seconds, 30 seconds to choose between;
5, an increase of input short circuit protection, can have the effect of preventing the EFC output short circuit and grounding problems;
6, an increase of anti-jamming circuit, the control panel can work more stable.
Specifications:
1, the working environment
Ambient temperature: -15 ~ + 55 ℃
Relative Humidity: 0 ~ 95%
Vibration: 25 HZ 2 mm
2, the power
Operating voltage: 24 ± 6 V DC
Grounding: negative ground (body)
Maximum Current: 2.5A, 24V
Dielectric strength: ≥500MΩ
CE4914091 generator governor slow start controller for PT (G) type fuel system for Cummins N, K series diesel generator sets. Module housing is 150mm X 105mm X 40mm aluminum parts, the surface spray. Epoxy potting. CE4914091 for normally closed unit 800KW or less. The same type of 4,914,090 units for normally closed 350KW or less.
Product performance and features:
1, reduce smoke, conducive to boot
2, strong against external interference, to maintain stable operation of the unit
3, the actuator short protection, extended service life.
4, an increase of smooth slow start process control, this new feature can solve the phenomenon of black smoke from the engine during start-up caused by the rapid refueling, reducing startup noise, engine speed up the time in 0 seconds, 5 seconds, 10 seconds , 15 seconds, 20 seconds, 25 seconds, 30 seconds to choose between;
5, an increase of input short circuit protection, can have the effect of preventing the EFC output short circuit and grounding problems;
6, an increase of anti-jamming circuit, the control panel can work more stable.
Specifications:
1, the working environment
Ambient temperature: -15 ~ + 55 ℃
Relative Humidity: 0 ~ 95%
Vibration: 25 HZ 2 mm
2, the power
Operating voltage: 24 ± 6 V DC
Grounding: negative ground (body)
Maximum Current: 2.5A, 24V
Dielectric strength: ≥500MΩ