Place of Origin: | China (Mainland) |
---|---|
Brand Name: | Repower |
Model Number: | SDRC-10IP |
Output Power: | 1 - 50W |
Output Type: | Single |
Size: | |
Weight: | 0.5kg |
Input Voltage: | 12V/24V |
Output Voltage: | 12V/24V |
Type: | |
Output Frequency: | |
Output Current: | 10A |
Quick Details
Specifications
Light + time control solar street light controller
1. Control: Micro Controller Unit utilizing dedicated software for precise control.
2. Charging mode: Pulse Width Modulated control, allows for high efficiency boost, recovery and float charging. Temperature compensation ensures that these parameters are adjusted for maximum battery condition and hence, prolonged battery life.
3. High accuracy discharging control:
Over-discharging control voltage modified by the battery discharging rate curve.
4. Circuit protection: protection against overload, short circuit and reverse connection,
Built in Transient Voltage Suppression protects against lightning. Reverse current leakage through PV
panel is blocked. Batteries are prevented from over-charging or discharging.
5. LED indication on system condition:
Indicating LEDs, monitor battery charging levels as well as battery state. LED monitoring of load conditions such as over load and short circuit as well as load on/off, are also provided.
Digital LED display number equal to time setting
6. Design standard: Operating temperature range from -35 to +50 deg C.
7. No adjustable hardware: Controller accuracy, stability and reliability is assured by the use of flash memory for all control parameters and set-points.
8. Operation: easy to operate, robust in design.
Specification:
Note: All printed Voltages are only for 12V system. Double voltages for 24 Volt systems.
Type | SDRC-10IP |
Rated charge current | 10Amps |
Rated load current | 10Amps |
Work voltage | 12/24V; |
Over load, short circuit protection | If the load current exceeds the rated current by 1.25 times for 60 seconds or by 1.5 times for 5 seconds. Short circuit protection will act if 3 times rated current happens; |
Self-consumption current | ≤ 6 mA |
Charge circuit voltage drop | ≤0.26V |
Load circuit voltage drop | ≤0.15V |
Over voltage protection | 17V (2 times for 24V system) |
Work temperature | Industry stage: -35°C to +55°C; |
Boost charge voltage | 14.6V (keep 10 min, 2 times for 24V system, only used when over-discharged last time) |
Direct charge voltage | 14.4V (2 times for 24V system) |
Float charge voltage | 13.6V (2 times for 24V system) |
charge return voltage | 13.2V (2 times for 24V system) |
Temperature compensation | '-5mv/°C/2V (Boost charge, Direct charge, Float charge, charge return voltage); |
Lower voltage indicate | 12.0V (2 times for 24V system) |
Over discharge voltage | 1.1V(no load, 2 times for 24V system, modified voltage by discharge rate of battery) |
Over discharge return voltage | 12.6V (2 times for 24V system) |
Control mode | PWM charge mode; modified discharge voltage by the discharge rate |
Certification | CE, RoHS |
LED indications | green-yellow-red battery levels for voltage warning and disconnected |
Battery type | Lead acid (GEL, flooded, AGM) |