| Output: | Analog Sensor |
|---|---|
| Place of Origin: | China (Mainland) |
Quick Details
Specifications
- Genuine replacement thermostat bimetal for your Whirlpool fridge freezer.
Suitable for the following models- Whirlpool ARC7451, ARC7451/1, ARC7453, ARC7453/1, ARC7453/1IS, ARC7453/1NBS, ARC7453/IS, ARC7517, ARC7517/IS, ARC7518, ARC7518/IX, ARC7518IS, ARC7518IX, ARC7558/IXAQUA, ARC7559IXAQUA, ARC7593, ARC7593/1, ARC7593/1IS, ARC7593/IS, ARC8009IX
Applications
- Refrigerator
- Electrical Blanket
- Showcase
- Ice Machine
- Electrical Stove
Features
- Ultra slim type
- Ideal for where space is premium
- Plastic seal available for hermetic protection
- Leadwire and terminal can be attached upon order
- Double contacts for extra reliability
- UL, VDE and TUV certificated
- Environmental friendly towards RoHS, REACH
Open temperature: 8C, Close temperature: -7C. + Fuse 66'C
|
Use |
Temperature control/Overheat protection |
|
Reset type |
Automatic |
|
Base material |
resist heat resin base |
|
Electrical Rating |
15A / 125VAC, 7.5A / 250VAC |
|
Max. Operating Temperature |
150°C |
|
Min. Operating Temperature |
-20°C |
|
Tolerance |
+/-5 C for open action(Optional +/-3 C or less) |
|
Protection class |
IP68 |
|
Contact material |
Solid Silver |
|
Dielectric Strength |
AC 1500V for 1 minute or AC 1800V for 1 second |
|
InsulationResistance |
More than 100MW at DC 500V by Mega Ohm tester |
|
Resistance Between Terminals |
Less than 100mW |
|
Diameter of bimetal disc |
Φ12.8mm(1/2″) |
|
Approvals |
UL/ TUV/ VDE/ CQC |
|
Terminal type |
Customized |
|
Cover/Bracket |
Customized |
Automatic Reset: A thermostat that automatically resets to its pre-trip contact configuration at a factory preset temperature.
Bimetal: Two metals with different rates of expansion molecularly bonded together to form a blade or disc for a thermostat.
Differential: (also known as Hysterisis) Refers to the difference between the opening and closing temperatures of a thermostat.
Maximum Temperature: (TM or Tm) In reference to a thermal cutoff, the maximum temperature to which the device can be subjected for a period of ten minutes without resuming conductivity once it has opened.
Minimum Differential: (also known as deadband) The minimum number of degrees between the actual open and actual close temperatures.
Normally Closed: Contacts open on temperature rise.
Normally Open: Contacts close on temperature rise.
S.P.D.T. (Single Pole/Double Throw): A three terminal switch possessing both Normally Open and a Normally Closed contact configuration.
S.P.S.T. (Single Pole/Single Throw): A switch with a single set of terminals and a single set of contacts.
Snap Action Thermostat: A thermostat with a Bimetal element that snaps to close the contacts when the activation condition is experienced. This construction permits the clean break of loads.
Thermal Cutoff: A thermal cutoff is an electrical safety device that interrupts electric current when heated to a specific temperature.
Tolerance: The allowable range above and below a nominal temperature.