Model Number: TGas-1031
Brand Name: Globeinstrument
Place of Origin: China (Mainland)

Specifications

Brief Introduction 

TGas-1031 on-line gas transmitter which adopts high performance sensor unit can continuously measure the concentration of gas on site and convert the concentration signal into digital or analog signal output(4-20mA analog signal,RS485 communication signal and switch quantity alarm signal to transmit remotely and drive). 

It is widely used in such industries such as petroleum, chemical, natural gas, coal, metallurgy, electric power, municipal administration, telecom,tunnel construction,gas storage station, special plants and other places where flammable gases or toxic and harmful gases exist. 

Main Features

Two kinds of optional mode of power supply, including centralized busbar type and independent area type

High and low concentration alarm, performing real-time monitor to gas

Anti-poisoning type gas sensor with high sensitivity 

Automatic modification of ageing curve of sensor, keeping constant alarm sensitivity

Function of automatic recognition of sensor trouble, function of high concentration gas above-norm of sensor

Function of automatic detection at starting up, and it has advanced function of self-diagnosis and self-reparing

The calibrated concentration value is adjustable, facilitating users to set by themselves

When the sensor loses the function of monitoring alarm because of ageing, the detector is capable of automatic recognition and alarm, so as to avoid missing report effectively

 

Technical Parameters

Parameters

Characteristics 

Detectable gas

Flammable gases, oxygen, poisonous and harmful gases 

Measurement precision 

±5%F.S

Repeatability 

2%

Measurement range

Refer to lectotype table for details 

Response time 

30s(T90)

Sampling method

Diffusion 

Working environment 

Temperature: -30℃ ~ 60℃

humidity: below 85% (nocondensation)

Remote control mode

By the adjustment mode by infrared remote control, the detector can be adjusted without opening of cover 

~ 20mA

output 

4~20mA output corresponding to 0 ~100%

 maximum load 800 ohms

Alarm output 

The effective alarm is 1 point or 2 points; each alarm shall use SPDT electronic relay.

Contact rating of alarm relay:

Ohmic load: 5A@24VDC or 120VAC or 240VAC

Inductive load: 50VA

Communication

Communication description: three-wire system parallel RS485 protocol, 32 points at most

Connection: Twisted pair with shield 

Distance: maximum 1000m

Input voltage 

24VDC±25%; power: 2W/way

Explosion-proof shell

Explosion-proof grade: ExdIICT5

Protection class: IP66

Using cable 

2.5mm2×4 screened cable line, outside diameter of cable is required to be between 6mm~9mm