Product Main

Quick Details

Jacket: PVC
Conductor Material: Aluminum
Type: High Voltage
Insulation Material: XLPE
Brand Name: Huadong
Place of Origin: China (Mainland)

Specifications

XLPE insulated  with rated voltage up to 35KV is the main product of Huadong cable Co.,Ltd.

Application

The XLPE insulated power cable is used in electric transmission and distribution system operating in vertical section, indoor, tunnels, mines. It was widely used in crowded public places such as high-rise building, large-rise library, gymnasium, station, subway, underground shop, etc. The XLPE insulated power cable not only has excellent electrical performance, environment resistant character & chemical-corrosion resisitant performance, simple structure, light weight, without restriction by laying fall, but it also has high temperature (90℃) for long time.

Standard

We produce these cables according to standard GB12706 and GB12666 (equivalent to IEC 60502 and IEC 60331), as well as BS, DIN and other internationl standards. In additional, we can also produce the Low-smoke free-halogen, Flame-retardant cables, or others according  to customer request.

Voltage

0.6/1, 3.6/6, 6/6, 6/10, 8.7/10, 8.7/15, 12/20, 18/30, 21/35, 26/35KV

Installation

(a) The enviromental temperature for install cables is not lower than 0℃ degree, in case that the temperature is lower than 0 degree when cable is laid, it must be heated,

(b) Layout fall: the cable layout fall is not limited by level fall.

(c) The non-armor XLPE power cable's bending radius should not be less than 15 times of cable O.D., the armor XLPE power cable's bending radius should not be less than 12 times of cable O.D..

Cable specification data

1.Cable rated voltage, core number, sectional area scope

  

No. Of core

Sectional area(mm2)

Rated vovoltageUO/U

  (kv)  

1st class

0.6/1

1.8/3

3.6/6

6/10

8.7/15

12/20

18/30

21/35

2nd calss

1/1

3/3

6/6

8.7/10

12/15

18/20

-

26/35

1 Core

 

1.5~800

25~800

25~1200

25~1200

35~1200

50~1200

50~1200

50~1200

2 Core

 

1.5~185

25~185

 

 

 

 

 

 

3 Core

 

1.5~400

25~400

25~400

25~400

35~400

50~400

50~400

50~400

4 Core

 

2.5~400

25~400

 

 

 

 

 

 

5 Core

 

2.5~400

25~400

 

 

 

 

 

 

2.Conductor D.C resistance of finished cable at 20 degree per kilometer is not more than the following values

Nominal Section Area(mm2)

1.5

2.5

4

6

10

16

25

35

50

70

95

120

150

185

240

300

400

500

630

800

Copper

core

12.1

7.41

4.61

3.08

1.83

1.15

0.727

0.524

0.387

0.268

0.193

0.153

0.124

0.0991

0.0754

0.0601

0.047

0.0366

0.0283

0.0221

Aluminum core

18.1

12.1

7.41

4.61

3.08

1.91

1.2

0.868

0.641

0.443

0.32

0.253

0.206

0.164

0.125

0.1

0.778

0.0605

0.0469

0.0367

3.Voltage test and partial discharge test

Item

Rated vltage

Uo/U (KV)

0.6/1

1.8/3

3.6/6

6/6 6/10

8.7/10 8.7/15

18/20

18/20 18/30

21/35

26/35

Voltage Test

Test Voltage

3.5

6.5

12.5

21

30.5

42

63

73.5

91

Test Time

5

 

 

 

 

 

 

 

 

Partial Discharge Voltage Test

Test Voltage

-

-

6.2

10.4

15.1

20.8

31.1

36.3

45

Discharge Capacity

-

-

10

10

10

10

10

10

10