Contact Load: | Low Power |
---|---|
Protect Feature: | 1 |
Size: | 103x55mm |
Theory: | Voltage Relay |
Brand Name: | zoanco |
Usage: | Protective |
Model Number: | 143 |
Place of Origin: | China (Mainland) |
power: | 9 to 28 VDC Volts Non-polarized |
Alarm Relay Contact Ratings: | 1A@ 24V DC |
Maximum Alarm Current (LED on): | <45mA |
Standby Current: | <200uA |
Smoke Alarm Sensitivity: | 15-0.3dB/m(with smoke sensor |
TemperatureAlarmSensitivity: | 57C (135F)(withheatsensor |
Quick Details
Specifications
Skype firealarm87 /wechat 15220176087
Conventional Fire Alarm Control System: FT143 4-wire Smoke & Heat Detector with Relay output
GeneralFT143 Smoke &Heat Detector with relay output, Operates by Advanced MCU Expert Algorithm Software.Key Specifications/Special Features
They work perfectly with all conventional intelligent fire control panels
Advanced MCU Expert Algorithm Software.
Easy installation and maintenance
Durable sensor head, no need for replacement
SMD circuit board design-satisfactory quality and reliability guaranteed
SPECIFICATIONS
Operating Voltage Range: 9 to 28 VDC Volts Non-polarized
Standby Current: 200A
Maximum Alarm Current (LED on): 45mA
Alarm Relay Contact Ratings: 2A@ 24V DC
Operating Humidity Range: 95%RH(40C2C) Relative Humidity, Non-condensing
Operating Temperature Range: -10C to 50C (14F to 122F)
Smoke Alarm Sensitivity: 1.06.26%FT
Temperature Alarm Sensitivity: 57C (135F) A1R (only for with heat sensor)
Height: 55 mm installed in Base
Diameter: 103 mm
3. INSTALLATION
NOTE: All wiring must conform to applicable local codes,
Ordinances, and regulations.
INSTALL the DETECTOR BASE
1. Open area smoke or heat detectors are intended for
Mounting on a ceiling or a wall in accordance with the fire
Standard in your country.
2. Attach mounting base to ceiling or wall. the base of
the detector can be mounted directly onto an electrical
Junction box such as an octagonal (75mm, 90mm or
100mm), a round (75mm), or a square (100mm) box
without using any type of mechanical adapter.
3. Position all wires flat against terminals, and fasten the
Wires on the terminals, See Figure 1.
4. Terminals function description:
Terminal 1: Relay Output -COM
Terminal 2: Relay Output NO/NC (default NO)
Terminal 3: DC Power
Terminal 4: DC Power +
Conventional Fire Alarm Control System: FT143 4-wire Smoke & Heat Detector with Relay output
GeneralFT143 Smoke &Heat Detector with relay output, Operates by Advanced MCU Expert Algorithm Software.Key Specifications/Special Features
They work perfectly with all conventional intelligent fire control panels
Advanced MCU Expert Algorithm Software.
Easy installation and maintenance
Durable sensor head, no need for replacement
SMD circuit board design-satisfactory quality and reliability guaranteed
SPECIFICATIONS
Operating Voltage Range: 9 to 28 VDC Volts Non-polarized
Standby Current: 200A
Maximum Alarm Current (LED on): 45mA
Alarm Relay Contact Ratings: 2A@ 24V DC
Operating Humidity Range: 95%RH(40C2C) Relative Humidity, Non-condensing
Operating Temperature Range: -10C to 50C (14F to 122F)
Smoke Alarm Sensitivity: 1.06.26%FT
Temperature Alarm Sensitivity: 57C (135F) A1R (only for with heat sensor)
Height: 55 mm installed in Base
Diameter: 103 mm
3. INSTALLATION
NOTE: All wiring must conform to applicable local codes,
Ordinances, and regulations.
INSTALL the DETECTOR BASE
1. Open area smoke or heat detectors are intended for
Mounting on a ceiling or a wall in accordance with the fire
Standard in your country.
2. Attach mounting base to ceiling or wall. the base of
the detector can be mounted directly onto an electrical
Junction box such as an octagonal (75mm, 90mm or
100mm), a round (75mm), or a square (100mm) box
without using any type of mechanical adapter.
3. Position all wires flat against terminals, and fasten the
Wires on the terminals, See Figure 1.
4. Terminals function description:
Terminal 1: Relay Output -COM
Terminal 2: Relay Output NO/NC (default NO)
Terminal 3: DC Power
Terminal 4: DC Power +