Place of Origin: | China (Mainland) |
---|---|
Model Number: | HF240-300 |
Brand Name: | Han Fang |
Type: | Biochemical Analysis System |
Quick Details
Specifications
Features:
1. Multi-channel post-spectro reaction system
2. Accurate reagent and sample collection system
3. High-efficient self-cleaning system
4. Intelligent accurate liquid level detection system
5. Easy and fast software operation system
6. Timely and thoughtful service network
Parameters:
1. Working Mode: Fully-auto, discrete, random access, measured in assay cup directly
2. Throughput: 300 tests/h
3. Colorimetric cup: 120 ultraviolet colorimetric cups (assay cup), quartz cuvette is optional.
4. Stirring mechanism: independent stirring pins, stir fully immediately after samples and reagents added
5. Cleaning mechanism: 120 colorimetric cups on reaction plate can be cleaned automatically and recycling, low costs and convenient to use
6. Liquid level measurement: measure the liquid level of samples and reagents automatically and warn of excrescent liquid
7. Emergency Samples: can be added at any time and priority detected automatically
8. Analysis project: as many as 45 items online biochemical test (standard configuration, extensible)
9. Sample position: 60 sample cups (or primary tube)
10. Reagent position: 45 R1 or R2 kits can be contained at one time (extensible and all of them will be refrigerated independently)
11. Sample injector: independent sample injector and reagent injector to reduce the cross contamination speed up the testing process
12. Response time: 0-999 seconds
13. Injector : ceramic trace plunger pump
14. Measure Method: end-point method, dynamic method, immunoturbidimetry, fixed time method, etc
15. Measurable wavelength: 340-800 nm (single/double wavelength)
16. Pre-dilution: samples whose concentration beyond the linear range can be diluted and remeasured automatically
17. System calibration: deduction of cell blank and reagent blank, automatic zero setting,
18. Quality control: quality control tests can be added. Data can be stored, displayed, counted and quality control chart can be printed
19. Calibration: linear/nonlinear, single point/ multi-point calibration
20. Light source: 12 v long-life halogen lamp
21. Light path system: multi-channel optical fiber, post-spectro, display the response curve during the whole course
22. Receiver: original imported optical sensor
23. Resolution: 0.0001 ABS
24. Sample volume: 1 μL - 100 μL
25. Dose: R1: 1-400 μL, R2: 1-400 μL
26. Power: 600W(Max)
27. Dimension: 930*730*1000(mm)
28. Operation system: windows2000 or above, English interface, various reports printed
29. The minimum of reagents: 180μL