| After-sales Service Provided: | Engineers available to service machinery overseas |
|---|---|
| Brand Name: | SYT |
| Place of Origin: | China (Mainland) |
| Voltage: | 380V |
Quick Details
Specifications
Technical parameters:
Power ultrasonic vibrating screen:
Power input: AC220V ± 10% 50~60Hz
Total current: ≤ 0.6A
High frequency electric current: ≤ 0.4A
Operating frequency: 38KHz
Operating modes: continuous and pulsed
Ambient temperature:-10~35℃
Working principle:
Power by ultrasonic vibration of ultrasonic sieving system, HF connection cables, transducers and Resonators composed. Electric power generated by high-frequency ultrasonic vibrating screen through the transducer converts vertical shock waves of high frequency sine-wave form, on these shock waves reached resonators resonators resonance, then by resonance vibration even transmitted to the screen surface. Sieve material in low frequency of three dimensions vibration at the same time, superimposed ultrasonic vibrations on can not only prevent the mesh block, and raise the yield of screening and precision.
Instructions for use:
1. first locks the transducer at stuck on wire rack (lock for 40~50kg), and shaker with ultrasonic rack mount.
2. power ultrasonic vibrating screen and vibrating screen, respectively powered Rotary Shaker for three-phase power supply, ultrasonic vibrating screen power supply for power supply, both require reliable grounding.
3. power ultrasonic vibrating screen panels OUT for ultrasonic output HF connector is inserted into the locking of ultrasonic, and check the connection is reliable. HF connection cable, plug the other end connected to the transducer, and ensure the sealed fixed firmly.
4. connect the ultrasonic vibrating ultrasonic HF power supply and connecting cable of the power supply, check the correct power on the ultrasonic switch. An audible "tick" sound, ultrasonic vibrating screens starting, the display shows "vibration amplitude μ m XXX", and enter the self-test State. By adjusting the amplitude knob can adjust the vibration amplitude (recommended levels of vibration 30~100 μ m, is conducive to screen life).
5. ultrasonic resonant power supply there are 2 kinds of working conditions: continuous "-" work status and pulse "" working condition, normal for consecutive-"working conditions. In a continuous "-" working mode, press the mode button, enter the pulse "" status. In the pulse, "" continuous key operation I, return to continuous duty.
Power ultrasonic vibrating screen:
Power input: AC220V ± 10% 50~60Hz
Total current: ≤ 0.6A
High frequency electric current: ≤ 0.4A
Operating frequency: 38KHz
Operating modes: continuous and pulsed
Ambient temperature:-10~35℃
Working principle:
Power by ultrasonic vibration of ultrasonic sieving system, HF connection cables, transducers and Resonators composed. Electric power generated by high-frequency ultrasonic vibrating screen through the transducer converts vertical shock waves of high frequency sine-wave form, on these shock waves reached resonators resonators resonance, then by resonance vibration even transmitted to the screen surface. Sieve material in low frequency of three dimensions vibration at the same time, superimposed ultrasonic vibrations on can not only prevent the mesh block, and raise the yield of screening and precision.
Instructions for use:
1. first locks the transducer at stuck on wire rack (lock for 40~50kg), and shaker with ultrasonic rack mount.
2. power ultrasonic vibrating screen and vibrating screen, respectively powered Rotary Shaker for three-phase power supply, ultrasonic vibrating screen power supply for power supply, both require reliable grounding.
3. power ultrasonic vibrating screen panels OUT for ultrasonic output HF connector is inserted into the locking of ultrasonic, and check the connection is reliable. HF connection cable, plug the other end connected to the transducer, and ensure the sealed fixed firmly.
4. connect the ultrasonic vibrating ultrasonic HF power supply and connecting cable of the power supply, check the correct power on the ultrasonic switch. An audible "tick" sound, ultrasonic vibrating screens starting, the display shows "vibration amplitude μ m XXX", and enter the self-test State. By adjusting the amplitude knob can adjust the vibration amplitude (recommended levels of vibration 30~100 μ m, is conducive to screen life).
5. ultrasonic resonant power supply there are 2 kinds of working conditions: continuous "-" work status and pulse "" working condition, normal for consecutive-"working conditions. In a continuous "-" working mode, press the mode button, enter the pulse "" status. In the pulse, "" continuous key operation I, return to continuous duty.