Product Main

Quick Details

Output: Analog Sensor
Theory: The eddy current principle
Usage: Vibration Sensor
Model Number: YD9810
Brand Name: Ce Zhen
Place of Origin: China (Mainland)

Specifications

Easy to install, without any adjustment

 

YD9810 three-wire shaft vibration sensor is easy to install, directly installed in the original place of Proximitor

YD9810 using more reliable screw terminals. The machine measured position, we generally require 

installation of a bearing near the X, Y two intervals of 90 ° YD9810 transmitter. For a standard double bearing 

rotating machinery, general configuration 4 sets vibrator.

 

Reliability and longevity of the eddy current sensor system

 

YD9810 with the our 8mm eddy current sensor probe. To adjust the gap of eddy current sensor, generally 

adjust the gap voltage (GAP +, COM) 10.0 ± 0.5V.

 

Features

 

1, Fault monitoring

 

Monitoring of rotating machinery rotor radial vibration; 

Monitoring the rotor imbalance, misalignment, mechanical loosening caused by vibration increases.

2, The measurement parameter

Radial vibration (displacement) of the peak to peak.

3, Unit Type

Bearing a variety of rotating machinery. Such as steam turbines, fans, compressors, motors, pumps and so 

on.

4, Installation requirements

YD9810 directly connect with the eddy current probe, extension cable, the installation location is the same

 with the proximitor .

5, Output Port 

4~20mA output (or 1 ∽ 5V). GAP original signal output.

 

Technical Specifications

 

1 Power supply: 22 VDC~ 30VDC

2, Frequency Response: (± 3dB): 5.0 ~ 1,000 Hz.

3, External probe: 8mm eddy current probe.

4, Buffered output (GAP): the original signal output.

5, Total vibration output: 4 ~20mA (or 1 V~ 5V).

6, Maximum load resistance: 600Ω

 

Physical indicators:

 

1, Dimensions: 78mm (length) × 70mm (height) × 37mm (width); DIN35 rail or screw mounting

2, Weight: 1kg

 

Environmental indicators:

 

1, Temperature: -25 ℃ to +65 ℃;

2, Storage: -40 ℃ to +100 ℃;

3, Humidity: 90% non-condensing.

4, YD transmitter should be mounted in the cabinets.