A. Display: three-phase voltage, phase current, generator power, power factor, frequency, battery voltage control, float charge current, run-time timing.
B. instructions: instructions mains, generators power indicator, power indication, various fault alarm indication.
C. Status Select: Auto / Manual / test run.
1 Auto: automatic control quasi-state, the state automatically detects mains, the unit automatically starts automatically cast nets, automatic back net, automatic shutdown, automatic fault trip, stop and alarm.
2 Manual: Manually start, manual closing, opening, stop
3 test run: in the city have lower power state, once a week to implement automated operation of the unit, make sure the unit in a good standby.
D. regulation: 
1 generator automatic voltage regulator and manual fine-tuning.
Generator automatic voltage regulation accuracy of ± 0.5% Ve (Note: Ve-rated
Manual generator voltage trim range ± 0.5% Ve
2 floating charge regulation.
0 ~ 5A floating charge (for control with battery) current can be adjusted.
Battery voltage DC12/24V
E. normal state control system: 
Automatic pre-heating system
Output voltage AC220V
Output power 1.5KW / Taiwan
Automatic control of temperature 50 ~ 55 ℃ (temperature unit)
In automatic mode, the unit ready to mains power failure automatically start within ≤ 8S automatically cast net, with a full load operation. When the unit to be ready state, the pre-heated water cooling system, since the cycle, automatic temperature control, the temperature of 50 ~ 55 ℃ unit.
F. Mains automatic detection: 
In automatic mode, through the external switch signal for long-term electricity status automatically detect discrimination. Once mains power failure, power failure, immediately enter automatically start state.
G. unit automatically starts automatically cast nets, automatic back net, automatic shutdown system: 
When the unit in the automatic mode, the mains power loss by system failures 3S confirmed automatically start unit (start times of a cycle). When the rated voltage and rated speed, automatic closing cast net, power supply. Since the start cast net operating time ≤ 12S. When utility power is restored to normal, 3S confirmed by the system, the unit automatically trip back network, delay 3 minutes, automatically shut down and automatically go to the next state of readiness to start automatically.
H. automatic protection: 
With overload, short circuit, high temperature, low oil pressure, under voltage, oil temperature, overspeed protection. With automatic trip stop function.
Overload, high water temperature, low oil pressure, since the launch failure, speeding, oil temperature Automatic fault alarm sound and light.
I. System Description: 
Systems with high reliability electrical products, automatic control, automatic start, automatic shutdown, such as automatic control, industrial PCs with Sino-foreign joint PLC control computer system to ensure reliability of operation.

Second, the expectations of manufacturing electricity, the unit automatically switches the system functions: 
The system has the mains, the unit automatically switches two-way power supply functions, mainly for automatic switching of mains and generator power. Under normal conditions the mains, power supply systems with mains priority functions, when the mains power failure, automatically switching the unit on the system side, the load is automatically powered by the unit; When utility power is restored to normal, the system can automatically switching the city electrical side, mains power supply to the load automatically, with priority mains power supply function.
According to the number of generators and mains can be divided into: single group mains switch with a single, stand-alone group and the double mains switch, double and single unit mains switch, dual unit with dual mains switch. Their functions are as follows:

A. Stand-alone group and single mains switch :
Parameter Display: mains voltage , generator voltage, load current.
Status Display Function: Mains normal / failure , the generator run / fault , mains / generator load .
Manual control: manual / automatic / maintenance, generator / mains load .
Automatic control functions: mains failure , delay confirmation ( time adjustable ) , issued starter set of instructions , the unit start operating normally , the generator load ; utility power is restored , the delay confirmation ( time adjustable ) , mains load. automatic shutdown unit load running 3 minutes ( adjustable ) after .
B. single group with dual mains switch :
Parameter display function : the way the mains voltage , Road mains voltage , generator voltage, load current.
Status display : the way electricity is normal / fault , Road mains normal / failure , the generator run / fault , all the way to the mains / Road mains / generator load .
Manual control: manual / automatic / maintenance, primary / standby electricity choice, generator / mains all the way / Road mains load .
Automatic control functions: the primary mains failure , delay confirmation ( time adjustable ) , spare City Electric load ; two mains fail, then issue a starter set of instructions , the unit start operating normally, the generator load ; utility power is restored , the delay confirmation ( time adjustable ) , electricity load , the unit load automatic stop running 3 minutes ( adjustable ) after .
C. Double unit with single mains switch :
Parameter Display: mains voltage , the 1st generator voltage , the 2nd generator voltage , load current.
Status Display Function: Mains normal / fault , One generator run / fault , II generator operation / fault , mains / One generator / II generator load . Manual control: manual / automatic / maintenance , master / standby generators choice , One generator / II generator / mains load .
Automatic control functions: mains failure , delay confirmation ( time adjustable ) , issued a directive starting primary unit , the primary unit start operating normally after load ; fault if the main unit occurs during starting or running, the automatic start standby unit , the standby unit start operating normally load ; utility power is restored , the delay confirmation ( time adjustable ) , electricity load , the unit automatically shut minute no-load operation (adjustable ) after .
D. double unit with dual mains switch :
Parameter display function : the way the mains voltage , mains voltage Road , One generator voltage , II generator voltage , load current. Status display : the way electricity is normal / fault , Road mains normal / failure, the 1st generator operation / fault , the 2nd generator operation / fault , the 1st generator / the 2nd generator / mains all the way / two Road mains load .
Manual control: manual / automatic / maintenance, master / standby generator to select the master / standby electricity hand selected One generator / II generator / mains all the way / Road mains load.
Automatic control functions: the primary mains failure, delay confirmation (time adjustable), spare mains load; two mains fail, delay confirmation (time adjustable), the primary unit start issuing instructions, the main starting with the unit operating normally after load; as the primary unit fails in the process of starting or running, the automatic start standby unit, the standby unit start operating normally load; utility power is restored, the delay confirmation (time adjustable), mains load, the unit load running 3 minutes (adjustable) automatically.
System uses foreign joint AIZIA ATS switch, to achieve reliable electrical and mechanical interlock to ensure operation.

Third, the self and the car automatically tune the FM carrier system functions:

A. The system functions and network with manual / automatic and network / "0 " position three sets of systems and options .
When the system is in manual and vehicle condition, two units is achieved by manually synchronize tables and nets. After the parallel operation , automatic frequency adjustment can be set by means of the implementation process unit operation automatic FM , auto carrier .
When the system is in the "0" state , the two units in the automatic mode after mains power failure while starting the unit , only one unit automatically cast net power , the other units delayed three minutes downtime. Ruoyi cast net unit fails , immediately start another power supply units and cast nets .

B. When the system is in auto and vehicle condition : two units in automatic mode after mains power failure while starting the unit , a cast net units automatically when power load is less than a rated power units , B units delay 3 minutes downtime when units have been running a continuous work 8 hours , B units will start immediately realize two units automatically and networks, and the load is transferred to the b -powered units , armor units back network , and delay 3 minutes downtime.

C. When the power supply when the load is greater than a one minute continuous rated power units, other units will start immediately and the power grid. The FM modulation device containing two units to ensure uniform load distribution.
This feature can be programmed according to user requirements.

D. The system also has a reverse power protection. Systems with high reliability electrical products, automatic control, automatic start, automatic cast nets, automatic back net, automatic shutdown, such as automatic control, industrial computer PLC industrial control computer system to ensure reliability.

E. Auto and car equipment, automatic frequency modulation carrier devices are used in quality and reliable products.

Note: The above is the expectations series diesel generator set automated and fully functional car, switching, specific customers choose models based on customer need for arrangements. You must be committed to the expectations of the perfect automated configuration, your satisfaction is our greatest pursuit!
The following are the expectations of selected ATS 300KW power automatic switching cabinet pictures, as a representative to give details of the description, pictures belong to the expectations of power, is forbidden, and offenders held liable