Product Main

Quick Details

After-sales Service Provided: No overseas service provided
Certification: CE
Power(W): 2.5
Voltage: AC85V~400V
Weight: 0.48kg
Temperature Control Accuracy: plus-minus 0.25%
Temperature Range: 0~450 centigrade
Model Number: HRTC-B-TINKO
Brand Name: Tinko
Application: Industrial
Type: mould temperature controller
Condition: New

Specifications

Features:

(1) Duallines LED display, Easy operation

(2) Unitdisplay

(3) Auto/Manual/Standbyfunction

(4) PID auto temperature control

(5) Selectable two thermocoupletypes (J or K)

(6) Selectable twotemperature scales (℃or℉)

(7) Selectable twotrigger output modes (Zero cross or phase angle)

(8) Multi diagnostic & alarm function

(9)Multi self-protect and equipment-protectfunction

(10) Selectabletwo start modes (Soft-start or Full-speed)

(11) 3-levelsparameters, use lock to keep high level parameters safe

(12) Recoverparameters default easily

(13) Calibration function


Specification
 :

Supply Voltage:AC85V~400V,50/60Hz

Temperature Control Type:PID Control/Manual

Temperature Sensor Type:Thermocouple J, K

Temperature  Measurement Accuracy:±0.25%

Temperature  Control Accuracy:±0.25%

Operating Temperature:0°C~50°C(32°F~122°F)

Storage Temperature:-20°C~70°C(-4°F~158°F)

Operating Humidity:10-80%RH(no condensayion)

Consumed Power:<2.5W

Control Output Type:triac(PWM mode);triac(SSR mode)

Temperature  Measurement Range:0°C~500°C(32°F~932°F)

Temperature  Setting Range:0°C~450°C(32°F~842°F)

Output Load Capacity:20A, 50W~2200W

                         100W~4400W

Power Switch type:HRTC-B: Rocker Switch


Protection Fuctions:

 1.Wide power supply range, AC85~400V

2.Thermocouple input protection, prevent module damaged by mis-connection

3.Thermocouple & heater inverse protection,prevent thermocouple damaged by mis-connection

4.Soft-start mode, avoid the humidity make the heater burn out


DiagnosticFunctions:

Alarm when the followings occurred

(1) Ultra-highor ultra-low Temperature

(2) Thermocouplebreak, short or inverse

(3) Thermocoupleis out of its position

(4) Heaterbreak, short or overload

(5) Outputdevice is damaged