Product Main

Quick Details

Insulation Material: XLPE
Jacket: PVC
Conductor Material: Copper
Application: Industrial
Model Number: KVV/KVVP/KVVP2/KVV22/KVVR/KVVRP
Brand Name: YITENG
Place of Origin: China (Mainland)
Standard: BS IEC ASTM DIN: Color: Black or orange or blue
Certification: ISO9001,AAA HONEST COMPANY: Sample: Free

Specifications

PVC Sheathed Flexible Control Cable XLPE Insulated Copper Conductor Braiding Shielded Cable

 

Specifications

Copper Conductor, XLPE Insulated, Braiding Shielded, PVC Sheathed Flexible Control Cable 
GB9330-1988,IEC,DIN,BS,450/750V AC

 

Control Cable 450/750V Copper Coductor PVC Insulated and sheathed Flexible Control Cable

Detailed Product Description

 

1.Standard

The control cable can be produced according to the standard GB9330-1988,IEC,DIN,BS,and the factory can also manufacture the cables in accordance with other standards.

 

2.Scope of Application

The control cable are suitable for the wiring of electrical controlling equipments and instrument,monitoring and controlling return circuit,electrical protection and measurement in power distribution unit under the circumstance that the rated voltage is up to 450/750V AC.

 

3.PVC sheath control cable

 

1)Max. Rated Temperature Of The Conductor Is 90oc

 

2)Max. Short-Circuit Temperature Of The Conductor Shall Not Exceed 250oc

 

3)Max. Sustaining Period Not Ecxeed 5 Seconds.

 

4)Installation Temperature Of Cable Shall Not Below 0oc .

 

5)Recommended Permissible Bending Radius:

A)For Non-Armormed Cable,Shall Not Be Less Than 6 Times Of The Cable's Overall Diameter.

B)For Armored Or Copper Tape Shielded Cable,Shall Not Be Less Than 12 Times Of The Cable's Overall Diameter.

C)For Soft Cable With Shield Layer,Shall Not Be Less Than 6 Times Of The Cable's Overall Diameter.

 

6)Used as power and connecting cables in mechanical engineering for tooling machinery, control unit, production lines, transportation equipment, conveyor and assembly lines as well as in plant construction under the circumstance that the rated voltage is up to 450/750V AC.

 

 

4.Character and Relevant Parameters
1. Long-term service temperature of the cable conductor: 70 0C
2. Rated voltage: 450/750V
3. Cable lying temperature ≥ 0 0C
4. Cores: 2, 3, 4, 5, 6, 7, 8, 10, 12, 14, 16, 19, 24, 27, 30, 37, 44, 48, 52, 61
5. Minimun bending radius:
Non armored ≥ Out diameter of cable 6 times
Armored layer or copper tape shielded ≥ Outer diameter of cable 12 times
Shielded layer soft cable ≥ Outer diameter of cable 6 times
PVC Insulated Control Cable Parameter (Example)

 

5.Type Name Section Area(mm2) No. Of Core
KVV Copper Conductor, PVC Insulated and Sheathed control cable 0.75 1.0 1.5 2.5 2-8 10 12 14 16 19 24 27 30 37
4.0 6.0 2-8 10 12 14
KVVP Copper Conductor, PVC Insulated and Sheathed, Copper-braid Screened Control Cable 0.75 1.0 1.5 2.5 2-8 10 12 14 16 19 24 27 30 37
4.0 6.0 2-8 10 12 14
KVVP2 Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Control Cable 0.75 1.0 1.5 2.5 2-8 10 12 14 16 19 24 27 30 37
4.0 6.0 2-8 10 12 14
KVVP2-22 Copper Conductor, PVC Insulated and Sheathed, Copper-tape Screened Steel-tape armored Control Cable 0.75 1.0 1.5 2.5 2-8 10 12 14 16 19 24 27 30 37
4.0 6.0 2-8 10 12 14
KVV22 Copper Conductor, PVC Insulated and Sheathed, Steel-tape armored Control Cable 0.75 1.0 1.5 2.5 2-8 10 12 14 16 19 24 27 30 37
4.0 6.0 2-8 10 12 14
KVVR Copper Conductor, PVC Insulated and Sheathed, Flexible Control Cable 0.75 1.0 1.5 2.5 2-8 10 12 14 16 19 24 27 30 37
4.0 6.0 2-8 10 12 14
KVVRP Copper Conductor, PVC Insulated and Sheathed, Braiding shielded Flexible Control Cable 0.75 1.0 1.5 2.5 2-8 10 12 14 16 19 24 27 30 37
4.0 6.0 2-8 10 12 14

  

6.Type& Specification

Type

Name

Section Area(mm2)

No. of Core

Application Site

KVV

Copper Conductor,PVC Insulated and Sheathed Control Cable

0.75 1.0 1.5 2.5

2-16

Permanent installation indoors,in cable ditches or pipes

4 6

2-14

10

2-10

KVVP

Copper Conductor,PVC Insulated and Sheathed,Braiding Shielded  Control Cable

0.75 1.0 1.5 2.5

2-61

Permanent installation indoors,in cable ditches or pipes where shielding is required

4 6

2-14

10

2-10

KVVP2

Copper Conductor,PVC Insulated and Sheathed,Copper-tape Screened Control Cable

0.75 1.0 1.5 2.5

4-10

Permanent installation indoors,in cable ditches or pipes where shielding is required

4 6

7-61

10

4-10

KVV22

Copper Conductor,PVC Insulated and Sheathed,Steel tape Armored Control Cable

0.75 1.0 1.5 2.5

7-61

Permanent installation indoors,in cable ditches,Be able to withstand stronger external mechanical force

4 6

4-14

10

4-14

KVVR

Copper Conductor,PVC Insulated and Sheathed,Flexible Control Cable

0.5-2.5

4-61

Installation indoors where flexibility and movability are required

KVVRP

Copper Conductor,PVC Insulated and Sheathed,Braiding shielded Flexible Control Cable

0.5 0.75 1.0

4-61

Installation indoors where flexibility shielding and movability are required

1.5 2.5

4-48

KYJV

Copper Conductor,XLPE Insulated and PVC Sheathed Control Cable

0.75 1.0 1.5 2.5

2-16

Permanent installation indoors,in cable ditches or pipes

4 6

2-14

10

2-10

KYJVP

Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Control Cable

0.75 1.0 1.5 2.5

2-61

Permanent installation indoors,in cable ditches or pipes where shielding is required

4 6

2-14

10

2-10

KYJV22

Copper Conductor,XLPE Insulated,Steel-tape Armoured,PVC Sheathed Control Cable

0.75 1.0 1.5 2.5

7-61

Permanent installation indoors,in cable ditches,pipes or underground Be cable to with stand stronger external mechanical force

4 6

4-14

10

4-10

KYJVP2

Copper Conductor,XLPE Insulated,Copper tape Screened,PVC Sheathed Control Cable

0.75 1.0 1.5 2.5

7-61

Permanent installation indoors,in cable ditches or pipes where shielding is required

4 6

4-14

10

4-10

KYJVR

Copper Conductor,XLPE Insulated,PVC Sheathed Flexible Control Cable

0.5-2.5

4-61

Installation indoors where flexibility and movability are required

KYJVRP

Copper Conductor,XLPE Insulated,Braiding Shielded,PVC Sheathed Flexible Control Cable

0.5 0.75 1.0

4-61

 Installation indoors where flexibility shielding and movability are required

1.5 2.5

4-48

 

7.Service Conditions

(1) The long-time working temperature of conductor of PVC insulated cable is 70oC

The long-time working temperature of conductor of XLPE insulated cable is 90oC

 

(2)  The temperature for laying the cables cannot be lower than 0oC.Permissible bending radius(r):unarmoured cable:r≥6D;(D: outer diameter of the cable);armoured or copper-tape screened cable:r≥12D;shielded flexible cable:r≥6D