Product Main

Quick Details

Model Number: MH5300
Brand Name: 0-5g/cm3
Place of Origin: China (Mainland)
intelligent online densimeter: densimeter

Specifications

Summary
MH5300 intelligent online densimeter (also known as online density transmitter) is a kind of concentration and density measurement for liquid continuous on-line equipment, can be directly used in the industrial production process. Density meter adopts advanced technology, including: a capacitance differential pressure sensor and a pressure relay on the connected, the insertion of the production process. A temperature sensor is arranged between the two pressure repeater, used for compensating temperature variation of the process liquid. MOHO Meng Hui intelligent online densimeter for two wire density transmitter, mainly used for industrial process control, density gauge of generating 4-20mA signal according to the size of the concentration and density, can perform remote calibration and monitoring through digital communication.
Characteristic
1, the density gauge is suitable for the static or flowing liquid, which is suitable for the pipeline and tank installation.
2, using two wire transmitter with integrated structure, no moving parts, simple maintenance.
3, continuous measurement of liquid density and temperature, can be directly used without interruption during the production process control.
4, dual four bit digital LCD display.
5, temperature and density of the two parameters can be displayed at the same time, to facilitate the industry standard density conversion.
6, density meter with a touch of several different liquid material.
7, convenient installation and use, can be inserted into the liquid display reading.
8, to simplify the repair, no need of regular cleaning.
9, density gauge calibration without standard reference source, without the need for laboratory calibration, without interruption.
Working principle
The working principle of intelligent online densimeter: liquid column of certain high pressure and the liquid density is proportional to. Namely: P= P GH type:
P -- a certain height of liquid column pressure
P -- the density of its liquid.
G -- measuring acceleration of gravity
H -- the height of the liquid level
According to the pressure measuring pressure value, at the height of the known measurement acceleration of gravity and liquid column conditions, can get the measurement of liquid density value.

Technical parameters
White: 4-20mA output current output, digital signal (HART protocol)
Go precision: 0.001g/cm3
White density range: 0-2g/cm3; 0-3g/cm3
White Instrument Power: 16-30VDC power supply, recommend the use of 24VDC
Go resolution: 0.001g/cm3
The temperature range of 0-100 DEG C: white
White: 0.5 DEG C temperature accuracy

Has the environmental temperature to 60 DEG C: -10

Application field
1, the sugar and wine: squeeze the fruit juice, syrup, Grape Juice, lime juice, alcohol density GL degrees, molasses, hexane / ethanol interface etc.;
2, the dairy industry: condensed milk, lactose, cheese, ricotta cheese, lactic acid;
3: coal, mining, potash, phosphate, salt, calcium compounds, copper, gold, limestone etc.;
4: lubricating oil, oil refining, aromatics, fuel oil, vegetable oil;
5, food processing: Tomato Juice, Grape Juice, lemon juice, tomato sauce, sugar, vegetable oil, fruit syrup, Guo Dong, jam etc.;
6, pulp and paper pulp, paper pulp cleaning: green, evaporator;
7, beverage processing: beer, soft drinks, wine, Instant Coffee,;
8, chemical: caustic soda, acid, urea, cleaning agent, polymer density, ethylene glycol, sodium chloride, sodium hydroxide etc.;
9: natural gas, petrochemical, oil and gas washing, kerosene, lubricants, oil / water interface etc..

MH5300 online densimeter
Code for installation structure
The P plug-in
S side mounted
G bend type
B pipeline type
Code range
1 0-1g/cm3
2 0-2g/cm3
3 0-3g/cm3
5 0-5g/cm3
Type code density meter
-30 DEG ~+90 DEG A at room temperature density gauge
B with temperature compensation, density gauge -30 DEG ~+180 DEG
C health online densimeter
-30 ~+300 degree centigrade high temperature D density gauge
E special request online densimeter
Code display
S with liquid crystal display
Y with liquid crystal display
Code with a liquid material
316L 1 Stainless Steel
2 Hastelloy alloy
3 titanium
4 tantalum
5 PTFE
6 Meng Naier
Code for installation flange dimensions
A DN50 (only double flange optional)
B DN80
C DN100
The specified D user
Code explosion proof grade
1 no
2 intrinsic safety type
Code insertion depth (mm)
Z users
Diaphragm distance code
J users
Example: MH5300-S1BS1A1Z800J500