| Output Frequency: | 50/60HZ |
|---|---|
| Type: | DC/AC Inverters |
| Output Voltage: | 220V/110V |
| Input Voltage: | 12/24/48V |
| Weight: | 47kg |
| Size: | 740*315*300mm |
| Output Type: | Single |
| Model Number: | W7- |
| Brand Name: | jzd |
| Place of Origin: | China (Mainland) |
Quick Details
Specifications
|
|
Model |
W7-4000 |
W7-5000 |
W7- 6000 |
||||||||
|
Output |
Continuous output power |
4000W |
5000W |
6000W |
||||||||
|
Surge ratings(20s) |
12000W |
15000W |
18000W |
|||||||||
|
Stared |
4HP |
5HP |
6HP |
|||||||||
|
Output wave form |
Pure Sine wave/Same as input(Bypass mode) |
|||||||||||
|
Nominal efficiency |
>88%(Peak) |
|||||||||||
|
Efficiency on line transfer mode |
>95% |
|||||||||||
|
Power Factor |
0.9-1.0 |
|||||||||||
|
Nominal Output Voltage |
220-230-240Vac |
|||||||||||
|
Output Voltage Regulation |
±10% RMS |
|||||||||||
|
Output Frequency |
50Hz ± 0.3Hz |
|||||||||||
|
Short Circuit Protection |
Yes, Current Limit Function (Fault after 1sec) |
|||||||||||
|
Typical transfer Time |
10ms(Max) |
|||||||||||
|
THD |
< 10% |
|||||||||||
|
DC Input |
Nominal Input Voltage |
12.0Vdc |
||||||||||
|
( *2 for 24Vdc, *4 for 48Vdc) |
||||||||||||
|
Minimum Start Voltage |
10.0Vdc |
|||||||||||
|
Low Battery Alarm |
10.5Vdc / 11.0Vdc |
|||||||||||
|
Low Battery Trip |
10.0Vdc / 10.5Vdc |
|||||||||||
|
High Voltage Alarm & Fault |
16.0Vdc |
|||||||||||
|
High DC Input Recovery |
15.5Vdc |
|||||||||||
|
Low Battery voltage recover |
13.0Vdc |
|||||||||||
|
Idle Consumption-Search Mode |
< 25 W when Power Saver On |
|||||||||||
|
Charger |
Input Voltage Range |
Wide: 90~135VAC / 164~243VAC; |
||||||||||
|
Output Voltage |
Depends on battery type |
|||||||||||
|
Charger Breaker Rating |
20A |
30A |
30A |
|||||||||
|
Max Charge Rate |
35A / 70-90A Max (Charger Current Control) |
|||||||||||
|
Over Charge Protection Shutdown |
15.7V for 12Vdc ( *2 for 24Vdc, *4 for 48Vdc) |
|||||||||||
|
Charger curve(4 stage constant current) |
Battery types ( *2 for 24Vdc, *4 for 48Vdc) |
|||||||||||
|
Battery type |
Fast Vdc |
|||||||||||
|
Gel U.S.A |
13.7 |
|||||||||||
|
A.G.M 1 |
13.4 |
|||||||||||
|
A.G.M 2 |
13.7 |
|||||||||||
|
Sealed Lead Acid |
13.6 |
|||||||||||
|
Gel Euro |
13.8 |
|||||||||||
|
Open Lead Acid |
13.3 |
|||||||||||
|
Calcium |
13.6 |
|||||||||||
|
De-sulphation |
15.5 for 4hrs |
|||||||||||
|
Remote Control |
Yes. Optional |
|||||||||||
|
Bypass & Protection |
Input Voltage Waveform |
Sine wave (Grid or Generator) |
||||||||||
|
Nominal Voltage |
120Vac |
230Vac |
||||||||||
|
Low Voltage Trip |
80V/90V±4% |
184V/154V±4% |
||||||||||
|
Low Voltage re engage |
90V/100V±4% |
194V/164V±4% |
||||||||||
|
High Voltage Trip |
140V±4% |
253V±4% |
||||||||||
|
High Voltage re engage |
135V±4% |
243V±4% |
||||||||||
|
Max Input AC Voltage |
150VAC |
270VAC |
||||||||||
|
Nominal Input Frequency |
50Hz or 60Hz (Auto detect) |
|||||||||||
|
Low Freq Trip |
47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz |
|||||||||||
|
High Freq Trip |
55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz |
|||||||||||
|
Overload protection |
Circuit breaker |
|||||||||||
|
Output Short circuit protection |
Circuit breaker |
|||||||||||
|
Bypass breaker rating |
30A |
40A |
40A |
|||||||||
|
Transfer switch rating |
30amp for UL & TUV |
|||||||||||
|
Max bypass current |
30amp |
|||||||||||
|
Mechanical Specification |
Mounting |
Wall mount |
||||||||||
|
Inverter Dimensions(L*W*H) |
598*218*179mm |
598*218*179mm |
||||||||||
|
Inverter Weight |
35KG |
45KG |
45KG |
|||||||||
|
Shipping Dimensions(L*W*H) |
740*315*300mm |
740*315*300mm |
||||||||||
|
Shipping Weight |
37KG |
47KG |
47KG |
|||||||||
|
Display |
Status LEDs / Status LEDs+LCD |
|||||||||||
|
Standard Warranty |
1 Year |
|||||||||||
|
Specification canbe adjustable as to customer requirements.Any change of product specification without notice. |
||||||||||||