Product Main

Quick Details

Model Number: LCD electromagnetic flowmeter
Brand Name: HS
Place of Origin: China (Mainland)
Measuring fluid: conductive fluid
Caliber: DN10-DN3000
Accuracy grade: +-0.5% RS.

Specifications

Application

It is mainly used for measuring the enclosed volume flow in pipes of conductive liquid and slurry. Including the acid, alkali, salt and other corrosive liquid.

Product features:

1, the measurement is not affected by the fluid density, viscosity, temperature, pressure and conductivity changes;

2, the measuring tube without obstructing the flow components, no pressure loss, lower straight pipe section;

3, Series nominal diameter DN15 ~ DN3000. Sensor lining and electrode materials have a variety of options;

4, converter using a novel excitation mode, low power consumption, zero point stability, high accuracy. Flow range up to 1500:1;

5, the converter can form a shape or a separation type and sensor;

6, converter using high performance 16 bit microprocessor, 2x16LCD display, convenient parameter setting, programming and reliable;

7, flowmeter for bidirectional measurement system, in which three integrator: forward, reverse total amount and the difference amount; can be displayed. Zhuang, reverse flow, and has a variety of output: Current, pulse, digital communication, HART;

8, converter using surface mount technology (SMT), with self test and self diagnosis function;

Parameter

Item The Specifications of electromagnetic flowmeter

Measuring fluid

conductive fluid

Caliber

DN10-DN3000

Electrode materials

Mo2Ti HC HB Pt Ta Ti

Lining Material

PTFE, PFA (resistance to negative pressure),

chloroprene rubber, polyurethane,

hard rubber (optional conductive ground rubber ≥ DN125)

Electrode Type

Standard type 316L, scraper-type (DN ≥ 50)

Dielectric conductivity

> 5μs/cm (water> 20μs/cm)

Accuracy grade

±0.5% RS.

Repeatability

±0.1%

Flow Range

0-10m/s

Maximum temperature of medium

A size ≤ 90 , min size ≤ 180 (rubber ≤ 65 )

Temperature

-25 - 65

Working pressure

1.0Mpa-4.0Mpa, the special supplier overpressure

Protection Level

IP65, IP67, IP68 (optional)

Output

4-20mA current output ,0-1kHz frequency output, pulse output per unit volume

Power

220VAC 110VAC

Standard

Q/SMAU2-2006

Auxiliary converter

BF900C/F

Flange

National standard GB9115, ANSI, JIS

Installation Type

Split, integrated