Tensile Strength: | 10.4 MPa |
---|---|
Rated Voltage: | 1000 v |
Application: | Low Voltage |
Model Number: | S2 |
Brand Name: | UPM Heat Shrink |
Place of Origin: | China (Mainland) |
Quick Details
Specifications
S2(n) Halogen Free Thin Wall Heat Shrink Tubing for General Purpose | ||||
Features | ||||
Insulation, Protection,Identification | Operating temperature: -40~125 ℃ | |||
Flame retardant VW-1(except clear) | Shrink temperature: 125 ℃ | |||
Halogen free, Flexible | Shrink Ratio: 2:1 & 3:1 | |||
Wide range of colors | Voltage Class: 600~1000 V | |||
Approvals | ||||
UL approval | File No.: | |||
Technical Data | ||||
Property | Test Method | Values | ||
Physical | Density | -- | 1.25~1.35 | |
Thermal endurance | -- | 125℃ | ||
Tensile strength | When test at 500mm/min. | ≥10.4 MPa | ||
Breakdown elongation | When test at 500mm/min. | ≥ 200% | ||
Aging(158 ℃/168hrs) | Tensile strength | When test at 500mm/min. | ≥ 7.3 MPa | |
Breakdown elongation | When test at 500mm/min. | ≥ 100% | ||
Heat shock | 4hrs. at 250℃ |
No cracking, drop or flow |
||
Cold bend | 1 hour at -30℃ | No cracking | ||
Water absorption 24h at 23℃ | -- | ≤0.5% | ||
Halogen free | IEC 61249-2-21 |
Cl:900ppm max. Br:900ppm max.T otal (Cl + Br) : 1500ppm max. |
||
Electrical | Dielectric breakdown voltage | -- | ≥ AC 2500V | |
Dielectric voltage Withstand | 1min.AC2500V | No breakdown | ||
Aging(158 ℃/168hrs) | Dielectric breakdown voltage | -- |
AC 2500V min. and more than 50% of the value obtained with unaged sample |
|
Dielectric voltage Withstand | 1min.AC2500V | No breakdown | ||
Volume resistivity | -- | ≥1014 Ω.cm | ||
Chemical | Copper stability | 168hrs at 158℃ 500mm/min. | Elongation≥100% | |
Flammability | UL224 | All tubing test Pass | ||
Note: The test methods conform to UL224. | ||||
Shrink ratio 3:1 | ||||
Reference | As supplied(mm) | After recovered(mm) | Standard length | |
UPM S2(n) | ID min. | ID max. | WT nom. | m |
1.5/0.5 | 1.5 | 0.5 | 0.5 | 200 |
3.0/1.0 | 3.0 | 1.0 | 0.7 | 200 |
4.5/1.5 | 4.5 | 1.5 | 0.7 | 100 |
6/2 | 6.0 | 2.0 | 0.8 | 100 |
9/3 | 9.0 | 3.0 | 1.0 | 50 |
12/4 | 12.0 | 4.0 | 1.1 | 50 |
15/5 | 15.0 | 5.0 | 1.2 | 50 |
18/6 | 18.0 | 6.0 | 1.3 | 50 |
24/8 | 24.0 | 8.0 | 1.5 | 25 |
30/10 | 30.0 | 10.0 | 1.7 | 25 |
39/13 | 39.0 | 13.0 | 1.9 | 25 |
50/16 | 50.0 | 16.0 | 2.5 | 1 |
60/20 | 60.0 | 20.0 | 2.6 | 1 |
70/23 | 70.0 | 23.0 | 2.6 | 1 |
80/26 | 80.0 | 26.0 | 2.8 | 1 |
90/30 | 90.0 | 30.0 | 2.8 | 1 |
100/33 | 100.0 | 33.0 | 3.0 | 1 |
Dimensions | |||||||||
Shrink ratio 2:1 | |||||||||
Reference | As supplied ID (mm) | After recovered(mm) | Standard length | Reference | As supplied ID(mm) | After recovered(mm) | Standard length | ||
UPM S2(n) | ID max. | WT | m/spool | UPM S2(n) | ID max. | WT | m/spool | ||
0.6 | 0.9±0.2 | 0.4 | 0.33±0.10 | 200 | 15.0 | 15.5±0.4 | 7.5 | 0.70±0.10 | 100 |
0.8 | 1.1±0.2 | 0.5 | 0.33±0.10 | 200 | 16.0 | 16.5±0.4 | 8.0 | 0.70±0.10 | 100 |
1.0 | 1.5±0.2 | 0.7 | 0.36±0.10 | 200 | 17.0 | 17.5±0.4 | 8.5 | 0.70±0.10 | 100 |
1.5 | 2.0±0.2 | 0.9 | 0.45±0.10 | 200 | 18.0 | 19.0±0.5 | 9.0 | 0.70±0.10 | 100 |
2.0 | 2.5±0.2 | 1.0 | 0.45±0.10 | 200 | 20.0 | 22.0±0.5 | 10.0 | 0.80±0.15 | 100 |
2.5 | 3.0±0.2 | 1.3 | 0.45±0.10 | 200 | 22.0 | 24.0±0.5 | 11.0 | 0.80±0.15 | 100 |
3.0 | 3.5±0.2 | 1.5 | 0.45±0.10 | 200 | 25.0 | 26.0±0.5 | 12.5 | 0.90±0.15 | 50 |
3.5 | 4.0±0.2 | 1.8 | 0.45±0.10 | 200 | 28.0 | 29.0±0.5 | 14.0 | 0.90±0.15 | 50 |
4.0 | 4.5±0.2 | 2.0 | 0.45±0.10 | 200 | 30.0 | 31.5±1.0 | 15.0 | 1.00±0.15 | 50 |
4.5 | 5.0±0.2 | 2.3 | 0.45±0.10 | 100 | 35.0 | 36.5±1.0 | 17.5 | 1.00±0.15 | 50 |
5.0 | 5.5±0.2 | 2.5 | 0.56±0.10 | 100 | 40.0 | 41.5±1.0 | 20.0 | 1.00±0.15 | 50 |
5.5 | 6.0±0.2 | 2.8 | 0.56±0.10 | 100 | 45.0 | ≥45 | 22.5 | 1.10±0.15 | 25 |
6.0 | 6.5±0.2 | 3.0 | 0.56±0.10 | 100 | 50.0 | ≥50 | 25.0 | 1.10±0.15 | 25 |
7.0 | 7.5±0.3 | 3.5 | 0.56±0.10 | 100 | 60.0 | ≥60 | 31.0 | 1.20±0.20 | 25 |
8.0 | 8.5±0.3 | 4.0 | 0.56±0.10 | 100 | 70.0 | ≥70 | 36.0 | 1.20±0.20 | 25 |
9.0 | 9.5±0.3 | 4.5 | 0.56±0.10 | 100 | 80.0 | ≥80 | 41.0 | 1.30±0.20 | 25 |
10.0 | 10.5±0.3 | 5.0 | 0.56±0.10 | 100 | 90.0 | ≥90 | 46.0 | 1.30±0.20 | 25 |
11.0 | 11.5±0.3 | 5.5 | 0.56±0.10 | 100 | 100.0 | ≥100 | 51.0 | 1.30±0.20 | 25 |
12.0 | 12.5±0.3 | 6.0 | 0.56±0.10 | 100 | 120.0 | ≥120 | 61.0 | 1.30±0.20 | 25 |
13.0 | 13.5±0.3 | 6.5 | 0.70±0.10 | 100 | 150.0 | ≥150 | 76.0 | 1.30±0.20 | 25 |
14.0 | 14.5±0.3 | 7.0 | 0.70±0.10 | 100 | 180.0 | ≥180 | 91.0 | 1.30±0.20 | 25 |
ID=Internal Diameter | WT= wall thickness | ||||||||
Typical application | |||||||||
Ideal for electrical insulation,strain relief,wire bonding and light harness jacketing | |||||||||
Common applications include electronic systems of subway, aircraft, submarine , control room facilities and sealed environment | |||||||||
Ordering | |||||||||
Standard color : Red,Blue, Yellow, Green, Black, Clear | |||||||||
Special colors are available on request | |||||||||
Spools as standard, cutting pieces or assorted kits available on request | |||||||||
Please specify specification, color, quantity when ordering | |||||||||
Cross reference | |||||||||
Raychem/Tyco : Versafit V2 / RNF-100 |