Product Main

Quick Details

Tensile Strength: 10.4 MPa
Rated Voltage: 1000 v
Application: Low Voltage
Model Number: S2
Brand Name: UPM Heat Shrink
Place of Origin: China (Mainland)

Specifications

S2(n) Halogen Free Thin Wall Heat Shrink Tubing for General Purpose
Features
       Insulation, Protection,Identification              Operating temperature: -40~125 ℃
       Flame retardant VW-1(except clear)              Shrink temperature: 125 
       Halogen free, Flexible               Shrink Ratio: 2:1 & 3:1
       Wide range of colors              Voltage Class: 600~1000 V
Approvals
UL approval File No.:
Technical Data
Property Test Method Values
Physical Density          -- 1.25~1.35
Thermal endurance          -- 125
Tensile strength  When test at 500mm/min. ≥10.4 MPa
Breakdown elongation  When test at 500mm/min. ≥ 200%
Aging(158 ℃/168hrs)   Tensile strength When test at 500mm/min. ≥ 7.3 MPa
Breakdown elongation When test at 500mm/min. ≥ 100%
Heat shock 4hrs. at 250 No cracking, 
drop or flow
Cold bend  1 hour at -30 No cracking
                    Water absorption 24h at 23          -- ≤0.5%
Halogen free  IEC 61249-2-21 Cl:900ppm max. Br:900ppm max.T
otal (Cl + Br) : 1500ppm max.
Electrical Dielectric  breakdown voltage          -- ≥ AC 2500V
Dielectric voltage Withstand    1min.AC2500V No breakdown
  Aging(158 ℃/168hrs)   Dielectric  breakdown voltage          -- AC 2500V min. and more than 
50% of the value obtained with 
unaged sample
Dielectric voltage Withstand    1min.AC2500V No breakdown
Volume resistivity          --   ≥1014 Ω.cm
Chemical  Copper stability  168hrs at 158℃ 500mm/min. Elongation≥100%
Flammability UL224 All tubing test  Pass
Note: The test methods conform to UL224.
Shrink ratio 3:1
Reference As supplied(mm) After recovered(mm) Standard length
UPM S2(n) ID min. ID max. WT nom. m
1.5/0.5 1.5  0.5  0.5  200 
3.0/1.0 3.0  1.0  0.7  200 
4.5/1.5 4.5  1.5  0.7  100 
6/2 6.0  2.0  0.8  100 
9/3 9.0  3.0  1.0  50 
12/4 12.0  4.0  1.1  50 
15/5 15.0  5.0  1.2  50 
18/6 18.0  6.0  1.3  50 
24/8 24.0  8.0  1.5  25 
30/10 30.0  10.0  1.7  25 
39/13 39.0  13.0  1.9  25 
50/16 50.0  16.0  2.5 
60/20 60.0  20.0  2.6 
70/23 70.0  23.0  2.6 
80/26 80.0  26.0  2.8 
90/30 90.0  30.0  2.8 
100/33 100.0  33.0  3.0 

Dimensions
Shrink ratio 2:1
Reference As supplied ID (mm) After recovered(mm) Standard length Reference As supplied ID(mm) After recovered(mm) Standard length
UPM S2(n) ID max. WT  m/spool UPM S2(n) ID max. WT  m/spool
0.6  0.9±0.2 0.4  0.33±0.10 200  15.0  15.5±0.4 7.5  0.70±0.10 100 
0.8  1.1±0.2 0.5  0.33±0.10 200  16.0  16.5±0.4 8.0  0.70±0.10 100 
1.0  1.5±0.2 0.7  0.36±0.10 200  17.0  17.5±0.4 8.5  0.70±0.10 100 
1.5  2.0±0.2 0.9  0.45±0.10 200  18.0  19.0±0.5 9.0  0.70±0.10 100 
2.0  2.5±0.2 1.0  0.45±0.10 200  20.0  22.0±0.5 10.0  0.80±0.15 100 
2.5  3.0±0.2 1.3  0.45±0.10 200  22.0  24.0±0.5 11.0  0.80±0.15 100 
3.0  3.5±0.2 1.5  0.45±0.10 200  25.0  26.0±0.5 12.5  0.90±0.15 50 
3.5  4.0±0.2 1.8  0.45±0.10 200  28.0  29.0±0.5 14.0  0.90±0.15 50 
4.0  4.5±0.2 2.0  0.45±0.10 200  30.0  31.5±1.0 15.0  1.00±0.15 50 
4.5  5.0±0.2 2.3  0.45±0.10 100  35.0  36.5±1.0 17.5  1.00±0.15 50 
5.0  5.5±0.2 2.5  0.56±0.10 100  40.0  41.5±1.0 20.0  1.00±0.15 50 
5.5  6.0±0.2 2.8  0.56±0.10 100  45.0  ≥45 22.5  1.10±0.15 25 
6.0  6.5±0.2 3.0  0.56±0.10 100  50.0  ≥50 25.0  1.10±0.15 25 
7.0  7.5±0.3 3.5  0.56±0.10 100  60.0  60 31.0  1.20±0.20 25 
8.0  8.5±0.3 4.0  0.56±0.10 100  70.0  70 36.0  1.20±0.20 25 
9.0  9.5±0.3 4.5  0.56±0.10 100  80.0  80 41.0  1.30±0.20 25 
10.0  10.5±0.3 5.0  0.56±0.10 100  90.0  90 46.0  1.30±0.20 25 
11.0  11.5±0.3 5.5  0.56±0.10 100  100.0  100 51.0  1.30±0.20 25 
12.0  12.5±0.3 6.0  0.56±0.10 100  120.0  120 61.0  1.30±0.20 25 
13.0  13.5±0.3 6.5  0.70±0.10 100  150.0  150 76.0  1.30±0.20 25 
14.0  14.5±0.3 7.0  0.70±0.10 100  180.0  180 91.0  1.30±0.20 25 
        ID=Internal Diameter                  WT= wall thickness
Typical application
       Ideal for electrical insulation,strain relief,wire bonding and light harness jacketing
       Common applications include electronic systems of subway, aircraft, submarine  , control room facilities and sealed environment
   
Ordering 
      Standard color : Red,Blue, Yellow, Green, Black, Clear
      Special colors are available on request 
      Spools as standard, cutting pieces or assorted kits available on request 
      Please specify specification, color, quantity when ordering
Cross reference
Raychem/Tyco : Versafit V2 / RNF-100