Product Main

Quick Details

Application: gas and oil well logging
Number of Conductors: 7
Jacket: Rubber
Insulation Material: PP
Conductor Material: Copper
Model Number: Seven-core
Brand Name: Wanquan
Place of Origin: China (Mainland)

Specifications

1. Application

Use for all kinds of gas and oil well operations such as logging, perforation, coring, etc.

2. Scope of Production

We can produce according to customers' requirements. At present, we can offer many kinds of logging cables with four temperature ratings of 150, 180232160. The diameter ranges from 5.6mm to 13.2mm.

6. Technical Parameters

W1BPP11.8  7*0.56

1) O.D. of Cable: 11.8mm

2) O.D. Inner Armor: 9.28mm

3) Conductor DC Resistance: 34 Ω/km  20

4) Insulation Resistance: 500MΩ/km  20

5) Insulation Resistance of High Temperature: 2.5MΩ/km

6) A.C. Voltage Withstand Test: 1000V  50Hz  5min

7) Capacitance: 0.19 μ F/km  800-1000Hz

8) Shielding Performance: 5V

9) Breaking Strength: 86kN

10) Suggest Working Tension: 40kN

11) Minimum Sheave Diameter: 510mm

12) Stretch Coefficient: 0.85m/km/5kN

13) Working Temperature for Long-term: 125

14) Temperature Range: -30 ~ 150

15) Weight of Cables: 494kg/km

16) The length of cable delivery is between 3000 meters and 8000 meters( between 9843ft and 26248ft) per reel, allowable deviation is -2%~3%. Any length can be delivered by mutual agreement.

Note: If choose the anti-sulfur cable, the breaking strength will be 85% of the value.

W1BPP11.8  7*0.56

1) O.D. of Cable: 11.8mm

2) O.D. Inner Armor: 9.28mm

3) Conductor DC Resistance: 34 Ω/km  20

4) Insulation Resistance: 500MΩ/km  20

5) Insulation Resistance of High Temperature: 2.5MΩ/km

6) A.C. Voltage Withstand Test: 1000V  50Hz  5min

7) Capacitance: 0.19 μ F/km  800-1000Hz

8) Shielding Performance: 5V

9) Breaking Strength: 86kN

10) Suggest Working Tension: 40kN

11) Minimum Sheave Diameter: 510mm

12) Stretch Coefficient: 0.85m/km/5kN

13) Working Temperature for Long-term: 232

14) Temperature Range: -50 ~ 260

15) Weight of Cables: 531kg/km

16) The length of cable delivery is between 3000 meters and 8000 meters( between 9843ft and 26248ft) per reel, allowable deviation is -2%~3%. Any length can be delivered by mutual agreement.

Note: If choose the anti-sulfur cable, the breaking strength will be 85% of the value.

4. Delivery Requirement:

The cable should be wrapped closely and tightly on the reel of which the diameter is not less than 50 times of the cable diameter, and there shouldn't be any loose. Both ends of the cable should be sealed, and the extra cable of the reel should not be less than 300mm.

5. Storage and transportation:

5.1 The cable should be avoided outdoor storage, and the reel should be stand on the ground.
5.2 It is not allowed to throw the reel with cable from high place during the transportation, mechanical damage is neither allowed.

5.3 When packing while hanging, it is not allowed to hang several reels together. The cable reel should be placed stably on the track and ship and fixed well with proper method to avoid hitting and turning over.