Product Main

Quick Details

Coil Number: Autotransformer
Coil Structure: Toroidal
Phase: Three
Usage: Power
Model Number: 100/35
Brand Name: EACHER
Place of Origin: China (Mainland)

Specifications

100kva Distribution Transformer
1) Top 1 in China: 120MVA EAF trans. 
2) ISO9001,ISO14001,CE 
3) Apply for IEC, JB, ANSI 
4) Up to 220kV, 200MVA 

 

?Main function and features

Furnace transformers are separated with normal power transformer with its characteristic of massive secondary currents which are the main products of Shenda Electric with many advantages both on quality and price. As an example a 30MVA unit at 150V would result in a secondary current of 115 kilo ampere. For these high secondary currents special bushings are required to be connected to the bus-bars. These bushings are specified with very specific arrangements to suit the bus-bar arrangement and cooling system. Furnace bus-bar are mostly water-cooled. The cooler are either of the oil forced (OFAF) or Oil forced water OFWF).

 

Shenda electric is renowned and appreciated by its reliable products performance and integrated services.  

Features:

1)       Low loss

2)       Low noise

3)       High efficiency

4)       Low partial discharge

5)       Strong mechanical strength and short-circuit withstand ability .

6)       Operation reliability

7)       Easy maintenance 

8)       Pretty outline and compact structure

9)       100% guaranteed no leakage

 

Brief specification

1)       Voltage class: 6~110 KV

2)       Capacity : 630 KVA to 120,000 KVA

3)       Short-circuit impedance : 4.5~21%

4)       Losses : No-load losses is fully comply with IEC standard requirements

 

35kV Arc Furnace Transformer Technical Parameters

 

Type Rated power
(kVA)
Connection
 symbol
Primary voltage
(kV)
Secondary Voltage
(v)
Regulation voltage step Type of taping short-circuit impedance(%) No-load loss On-load loss
HSSPZ-1500/35 1500 Yd11 35 290~157 10 On-load 5.5 2.6 23
HSSP-3200/35 3200 D-Y,d0-11 35 240~138 4 No-load 7 5.3 41.1
HSSPK-3200/35 3200 D-Y,d0-11 35 240~138 5 No-load 18.65 5.3 91.1
HJSSP-5000/35 5000 Yd11 35 212~155 5 No-load 7.5 9.3 55
HJSSP-5500/35 5500 Yd11 35 240~130 6 No-load 7 9.1 52.5
HJSSP-7000/35 7000 Yd11 35 240~140 8 No-load 6.5 9.4 77
HJSSPZ-9000/35 9000 Yd11 35 239~163 9 On-load 8.5 11.6 97
HSSP-9000/35 9000 Yd11 35 320~180 8 No-load 6 11 116
HJSSPZ-10000/35 10000 Yd11 35 260~188 9 On-load 8.5 17.2 187
HSSPZ-10000/35 10000 Yd11 35 300~160 13 On-load 6.5 12 97
HSSPZ-12500/35 12500 Yd11 35 250~150 9 On-load 9 19.7 134
HSSP-12500/35 12500 Yd11 35 340~195 11 No-load 8 13.9 154
HSSP-15000/35 15000 D-Y,d0-11 35 353~160 8 No-load 8 20 107
HSSPZ-16000/35 16000 Yd11 35 375~200 15 On-load 7 16.4 16.1
HJSSPZ-16000/35 16000 Yd11 35 310~190 13 On-load 7 19.2 195.6
HSSPZ-20000/35 20000 Yd11 35 400~270 13 On-load 7 20.7 207.7
HJSSPZ-20000/35 20000 Dd0 35 320~170 11 On-load 6.5 30.4 30.4
HSSPZ-25000/35 25000 Yd11 35 509~302 13 On-load 7.5 28.5 28.5

 

 

Application:

 Arc furnaces are used in steel industry for smelting scrap iron and for refining steel.  Other application areas are :

 1)    Smelting glass and ceramics

 2)    Manufacturing or refining many other materials etc. ferrochromium, ferromanganese, different abrasive materials (oxides and nitrides), semiconducting base materials, nanopowders etc.

 3)    Electric arc furnace (EAF) transformers are required for many different furnace processes and applications . they are built for :

    a , Steel furnaces, mainly long arc

    b, Landle furnaces

    c, ferro-alloy furnace and similar with short or submerged are

    d,Smelting of other materials