Product Main

Quick Details

Insulation Material: PVC
Conductor Type: Stranded
Conductor Material: Copper
Application: Underground
Type: Insulated
Model Number: BV 16 SQMM
Place of Origin: China (Mainland)

Specifications

Specifications 

 

PVC insulated electric wire:

 

Our PVC insulated elecric wire can be produced and provided according to standard GB/T 5023,IEC 60227,BS 6004,JB 8734.It's used of  AC rated voltage 450V/750V(U0/U)and below for the following :lighting ,electrical installation,the connection between instrumentation and telecommunication equipment, partial PVC insulated electrical wire are used of 300/500V and below for the electrical equipments .

 

Model

 

Copper (aluminum) conductor PVC insulation wire ( IEC 01 BV) (BLV)

 

Copper conductor PVC insulated PVC sheathed round wires (60227 IEC 10 BVV)

 

Copper (aluminum) conductor PVC insulated PVC sheathed flat wires ( BLVVB)

 

Detailed Product Description

 

Wire / PVC Insulated Electrical Wire/ 450/750V Wire

 

PVC Wire is used for lighting, electronic equipment, instument and communication equipment with rated voltage 450/750V or less

Specification:

1. The rated voltage of the wires should equal to or higher then the rated voltage of the system when wires are used at AC system. If the wires are used at DC system, the rated voltage of system should lower then 1.5 times as high as rated voltage of cable and wires. The working voltage of the system could be 1.1 times as high as the rated voltage of the cable.

2. The long term working temperature should lower then 70oC. The working temperature of BV-90 should lower then 90oC. And the laying temperature should higher then 0oC.
3. The curve diameter of the wire should longer than 8 times of the diameter of the outer diameter of cable and wires if their outer diameter is 25 mm or above. If the diameter of cable and wires is above 25 mm, the curve diameter should be at least 12 times of the outer diameter of the cable and wires.

 

 

 

Type

Name

Laying place and requirement

Long term working Temperature 0C

60227IEC01  05

BV

BLV

Copper conductor PVC insulated wires

Aluminum conductor PVC insulated wires

Fixed laid indoors

Conduit etc.

 

     70

60227IEC07

(BV-90)

Heat resistant copper conductor PVC insulated wire at 90 0C

Mainly be laid at the places of high temperature environment and can be laid indoors ,conduits.

 

 

    90

BVR

Copper conductor PVC insulated flexible cable

Be for laying permanent place where flexible required.

  

 

    70

60227IEC10

(BVV) BVV

Copper conductor PVC insulated PVC sheathed round wires

Fixed laid, fit for the places with high mechanical protection and moisture place, can be laid in the air or underground.

 

 

     70

 

BLVV

Aluminum conductor PVC insulated PVC sheathed round wires

BVVB

Copper conductor PVC insulated PVC sheathed flat wires

BLVVB

Aluminum conductor PVC insulated PVC sheathed flat wires

60227IEC02(RV)

60227IEC06(RV)

Copper conductor PVC insulated flexible connector wire

Mainly used at middle and light style moving electronics, home appliances, power and lighting and the places where flexible required

 

 

 

     70

60227IEC42(RVB)

Copper conductor PVC insulated flat flexible connector wire

RVS

 

Copper conductor PVC insulated flexible twisting connector wire

60227IEC52(RVV)

60227IEC53

Copper conductor PVC insulated PVC sheathed round flexible connector wire

60227IEC08

(RV-90)

 

Cu conductor heat resistant PVC insulated flexible connector wire at 900C

Mainly used at the places where heat resistance is required

 

90


ecaltvv