Connection: | Plug In |
---|---|
Model Number: | 12v2a |
Brand Name: | xintaide |
Place of Origin: | China (Mainland) |
plug in: | au us uk eu |
input: | 110-240v |
output power: | 24w |
certification: | ce fcc saa rohs kc |
oem: | yes |
color: | black |
Quick Details
Specifications
12V AC Adapter 12V 2A Spec as follow:
Product Electric Parameters |
||||
Input specification |
Input voltage |
AC100V---240V |
||
|
Input frequency |
50-60Hz |
||
|
Input surge |
20A@120VAC 40A@230VAC |
||
Output specification |
Output voltage can be adjusted |
±10% |
||
|
Start-up time |
<1S(input230V Io=100%) |
||
|
keep time |
>20mS (input230V,Io=100%) |
||
|
Voltage regulation |
(Full load) <0.5% |
||
Protection function |
Overload protection |
105% - 150% rated power, automatic recovery |
||
|
Over-voltage protection |
105% - 150% of the rated voltage |
||
Insulation intensity |
Input---output |
1500VAC/1min |
||
|
Input---ground |
1500VAC/1min |
||
|
Input---ground |
500VAC/1min |
||
Safety standards |
According with GB4943, UL60950-1,EN60950-1 standards. |
|||
E M C standards |
According with GB9254, EN55022 class A EN61347-2-13:2008 standards |
|||
Environmental |
working temperature |
- 20 ° ~ 60 ° c / 20% ~ 90% RH (no frost) |
||
|
Storage temperature |
- 40 ° ~ 85 ° c / 10% ~ 95% RH (no frost) |
||
|
height above sea level |
<2000M |
||
Cooling method |
Cooling method |
Natural cooling air convection |
||
Product Type Table |
||||
Product model |
output specification |
ripple, noise |
efficiency |
|
12v2a |
12V |
2A |
100mV |
85% |