pFlow Clip & Clear Ultrasonic Flowmeter

Installation and Wiring

Before installing the transducers, clean the pipe surface where the transducers are to be mounted.
Choose a section of sound conducting pipe for installing the transducers. Apply a wide band of sonic
coupling compound down the center of the face of each transducer as well as on the pipe surface.

Once the installation position is fixed, then you can install the flow meter. Refer to the right picture
during the installation and make sure that the transducer mounting direction is parallel with the flow.

Specifications

Flow Range: 0.03 ft/s ~ ±20ft/s (0.1m/s ~ ±6m/s)

Accuracy: ±1.5 % FS

Repeatability: 0.3 %

Measuring Medium: Water

Pipe Material: PVC-U/PP-R

Protection Rate: IP54

Power Supply: 10~36VDC, @500mA Max

Transmitter: ABS Plastic Enclosure

Power Supply Cable: 3.0 m (standard)

Display: LCD Display

Temperature: 0~50 ℃ 