Product Main

Quick Details

Model Number: RM02
Brand Name: RAY MEDICAL
Place of Origin: China (Mainland)

Specifications

RM02---12.1" color TFT touch screen patient monitor

12.1" color TFT touch screen
Windows style, Multi-channel display
Big font interface
ST and arrhythmia analysis
Drug dose calculation and titration table
OxyCRG dynamic view display
Respiration monitoring with apnea alarms
Alarm review, arrhythmia review
Patient info. Input
Anti-defibrillation design
NIBP over pressure protection
Plug-in rechargeable battery, AC/DC available. 
Supporting wire or wireless network.
 
Adopting Aiah(TM) ECG technology, anti-interference, be able to collect the weak ECG signal away from interference.
Adopting Surepeb(TM) NIBP technology, accurate measurement to high blood pressure patient and low blood pressure patient.
 
SP02
Nellcor(TM)  OxiMax(TM) is the world leading SpO2 technology
Nellcor(TM)  OxiMax(TM) delivers excellent performance,
even in the difficult monitoring conditions of low perfusion and signal interference, including patient motion.
 
ETCO2
 
Collaborate with Respironics, Plug and Play EtCO2 monitoring.
CAPNOSTAT mainstream sensor for optimal performance in monitoring intubated patient. Small, durable and lightweight 
 
mainstream sensor provides accurate
and reliable monitoring for all intubated patients from neonates to adults. Loflo sidestream sensor for monitoting non-
 
intubated patient.
Flexible, compact CO2 sensor provides consistent and reliable monitoring of adult, pediatric and neonatal patients.
 
Multi Mounting Solutions
 
ECG
Lead Mode :  5 Leads (R, L, F, N, C or RA, LA, LL, RL,V) 
Lead selection : I, II, III, avR, avL, avF, V
Wave form : 2 ch
Lead mode : 3 Leads ( R, L, F or RA, LA, LL) 
Lead selection : I, II, III,
Wavef orm : 1 ch
Gain : 2.5mm/mV, 5.0mm/mV, 10mm/mV,20mm/mV, auto
HR and Alarm Range   Adult :  15 ~ 300 bpm
                    Neo/Ped : 15 ~ 350 bpm
Accuracy :  ±1% or±1bpm, which is greater
Resolution : 1 bpm 
Sensitivity :  > 200 (uVp-p) 
Differential Input Impedance : > 5 MΩ
CMRRMonitor > 105 dB 
        Operation > 105 dB 
        Diagnosis > 85 dB
Electrode offset potential : ±300mV 
Leakage Current : < 10 uA
Baseline Recovery :  < 3 S After Defi. 
ECG Signal Range : ±8 m V ( Vp-p ) 
Bandwidth : Surgery  1 ~ 20 Hz
Monitor     0.5 ~ 40 Hz
Diagnostic  0.05 ~ 130 Hz
Calibration Signal  :  1 (mVp-p),  Accuracy:5%
ST Segment Monitoring Range :   Measure and Alarm -2.0 ~ +2.0 mV
 
ARR Detecting  Type: ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT>2,BRADY, MISSED BEATS, PNP, PNC,Alarm 
 
Available,Review Available
 
Respiration
Method Impedance between R-F(RA-LL)
Differential Input Impedance :  > 2.5 MΩ
Measuring Impedance Range :  0.3~3 Ω
Base line Impedance Range : 200~4 KΩ
Bandwidth : 0.1~2.5Hz
Resp. Rate     Measuring and Alarm Range
              Adult 0 ~ 120 Brpm 
              Neo/Ped 0 ~ 150 Brpm 
              Resolution 1 Brpm 
              Accuracy ±2 Brpm
Apnea Alarm :  10 ~ 40 S
 
NIBP 
Method :  Oscillometric
Mode :  Manual, Auto, STAT                        
Measuring Interval in AUTO Mode :  1, 2, 3, 4, 5, 10, 15, 30, 60, 90,120, 180, 240,480 (Min)
Measuring Period in STAT Mode :  5 Min
Pulse Rate Range : 40 ~ 240 bpm
Alarm Type :  SYS, DIA, MEAN
Measuring and alarm range        Adult Mode:
                              SYS 40 ~ 270 mmHg 
                              DIA 10 ~ 215 mmHg 
                              MEAN 20 ~ 235 mmHg
 
Pediatric Mode:   SYS 40 ~ 200 mmHg 
                DIA 10 ~ 150 mmHg 
                MEAN 20 ~ 165 mmHg
Neonatal Mode:   SYS 40 ~ 135 mmHg 
                DIA 10 ~ 100 mmHg 
            MEAN 20 ~ 110 mmHg
Resolution  1mmHg
Accuracy :  Maximum Mean error ±5mmHg
           Maximum Standard deviation ±8mmHg
Overpressure Protection    Adult Mode 297±3 mmHg 
                       Pediatric Mode 240±3 mmHg 
                       Neonatal Mode 147±3 mmHg
SpO2
Measuring Range:  0 ~ 100 % 
Alarm Range:   0 ~ 100 % 
Resolution :   1 %
Accuracy:    70% ~ 100%  2 %
            0% ~ 69% unspecified
Actualization intervalabout :  1 Sec. 
Alarm Delay : 10 Sec.
Pulse Rate        Measuring and Alarm Range 20~300 bpm
                Resolution  1bpm
                Accuracy ±3bpm                              
TEMP
Channe      2
Measuring and Alarm Range : 0 ~ 50 ℃
Resolution :   0.1 ℃
Accuracy: ±0.2 ℃
Actualization intervalabout : 1 Sec.
Average Time Constant :  < 10 Sec.
 
IBP
Label    ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range    ART 0 ~ 300 mmHg 
                          PA -6 ~ 120 mmHg
                          CVP/RAP/LAP/ICP-10 ~ 40 mmHg
                          P1 / P2-10 ~ 300 mmHg 
 
Press Sensor      Sensitivity 5  uV/V/mmHg
                Impedance 300-3000Ω
 
Resolution       1 mmHg
Accuracy        ±2% or 1mmHg which is greater
Actualization interval about 1 secretary
 
Standard:  ECG, Respiration, NIBP, SpO2, Pulse Rate, Temperature
Optional:  Nellcor SpO2, EtCO 2, IBP, Thermal Recorder