Model Number: | HKCX-DZ-RAN |
---|---|
Brand Name: | HK |
Place of Origin: | China (Mainland) |
Quick Details
Specifications
Diameter of the probe is only 18mm, the diameter of standard external protecting barrel is only 25mm.
Diameter of thermal insulation protecting barrel can be 35mm or 45mm.
Highlights
Available for the measurement in deep well with small drill tools and high temperature: The diameter of standard external protecting barrel is only 25mm. Assembled with thermal insulation protecting barrel, the maximum pressure bearing capacity is 220MPa and the maximum working temperature is 260 ℃.(See details in below table).
Precise measurement, reliable stable performance: Equipped with shock proof accelerometer, the probe is featured with high linearity, small temperature drift, good repeatability and other characteristics, thus can ensure precise measurement data.
Particular Power-off protection: It will not affect the instrument's normal work if there is a sudden outage caused by special strong vibration or impact, which increases the success rate of the measurement.
Long working hours with low power consumption design: With the low power consumption design, a fully charged battery can guarantee a continuous working for more than 80 hours.
Good resistance to impact and vibration: The instrument is radially and axially equipped with multistage buffering devices, such as rubber, springs, hydraulic anti-seismic shock absorber, which effectively improves the impact resistance as well as the vibration resistance of the instrument.
Precise measurement, stable and reliable performance: The probe is adopted with high-precision acceleration sensor, which is in high linearity, good repeatability and other characteristics to ensure the probe-tube to get accurate and reliable measurement data.
Wide adaptability, lowprocurement cost: The same probe-tube can be used for multi-shot as well as for fixed-point measurement. Equipped with different downhole protecting system, it is available for self-floating measurement, suspending measurement and dropping measurement. It is very easy for the drilling teams to manage the instruments and reduce their procurement cost.
Diameter of
External
Protecting
Barrel
Maximum
Pressure
Bearing
Capacity
Working Temperature
of
Instrument
25
100MPa
125℃
35
150MPa
260℃
45
220MPa
260℃
Measurement
Range
Precision
Inclination
0~180°
±0.10°, ±0.15°
Magnetic Azimuth
0~360°
±1.0°, ±1.2°(inclination≥6°)
Gravity High Side
0~360°
±1.0°, ±1.2°(inclination≥6°)
Magnetic High Side
0~360°
±1.0°, ±1.2°(inclination≤8°)
Delay Time Range
2-299min
Time-interval Range
12-3600s
Collecting points
3600 points
Working Temperature
of the Probe
-40~125℃
Technical Parameters
Item