Rated Current: | 1080A |
---|---|
Rated Voltage: | 380V/220V |
Rated Power: | 600KW |
Frequency: | 50HZ |
Speed: | 1500RPM |
Output Type: | AC Three Phase |
Model Number: | JGJ600GF |
Brand Name: | FD |
Place of Origin: | China (Mainland) |
Engine Model: | 8190ZL |
Number of Cylinders: | 8 |
Cylinder arrangement: | Vertical in line |
Cycle: | 4 stroke |
Fuel Consumption at 100% Load: | 205 g/kw.h |
Alternator Model: | MX-600-4 |
Exciter type: | Brushless, Self-excited |
Protection Grade: | IP23 |
Quick Details
Specifications
600KW Jichai Land Diesel Generator for Sale
Genset Main Technical Data
3-PH, 50Hz@1500RPM, 380/220V (Also Can Be Made According To Customers' Special Requirements)
Generator Model |
JGJ600GF |
Prime power |
600KW |
Standby power |
660KW |
Voltage |
380V/220V |
Frequency |
50HZ/1500 rpm |
Power factor |
0.8(lag) |
Governor type |
Electric |
Prime Power : Prime power is available for an unlimited number of annual hours in variable load application, in accordance with GB/T2820-97; A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation.
Standby Power Rating : The standby power rating is applicable for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating.
Reliable Performance
Voltage regulation
Voltage regulation maintained within ±0.5% as follow:
●Power factor Between 0.8~1.0 lag
●From no load to full load, any steady load
●Speed droop variation under 4.5%
Frequency/Speed undulation
●Change load from 0-100%, Frequency/Speed Droop Ratio within 5%
●Load from 25-100%, any steady load Frequency/Speed undulation within 0.25%
Effect factor of telecom
●Telephone Influence Factor (TIF) : Less than 50
THF : Less than 2%
●ISO8528, GB/T2820
●EN12601:2001, EN60034-22:1997, EN60204-1:2006
●ISO9001:2008 Quality Control System
Open Type
Overall size (L*W*H)
5250×1500×2700
Weight:9700kg
Jichai Diesel Engine
Technical Data
Engine Model |
8190ZL |
Number of Cylinders |
8 |
Cylinder arrangement |
Vertical in line |
Cycle |
4 stroke |
Aspiration |
Turbocharged after cooled |
Bore×Stroke |
190x210 mm |
Output Power/Speed |
720KW/1500rpm |
Speed Governor |
Electrical |
Cooling System |
Water-cooled , 40℃ Radiator As Standard, 50℃ Is Optional. |
Speed Stability (%) |
≤5% |
Fuel Consumption at 100% Load |
205 g/kw.h |
Starter Motor |
DC24V, |
Alternator Specification
Technical Data
Brand |
MARATHON |
Alternator Model |
MX-600-4 |
Capacity |
600KW |
Voltage |
220/380V |
Frequency & Speed |
50HZ/1500RPM |
Exciter type |
Brushless, Self-excited |
Power factor |
0.8 |
Voltage Adjust range |
≥5% |
Voltage Regulation NL-FL |
≤±0.5% |
Insulation Grade |
H |
Protection Grade |
IP23 |
Control System
1. Standard: HGM180HC Key Start Providing the standard functions as follows: (Also can be made according to the customers' special requirements) *Start/Stop controller *Ampere meter *Voltmeter and selector switch *Frequency meter/ Water temperature gauge/ Oil pressure gauge/ Hour counter/ Battery voltage meter *Emergency stop pushbutton *Alarm System: Over speed, High Engine Temperature Low Oil Pressure, Charge Fail *Protection System: Over speed, High Engine Temperature, Low Oil Pressure, Emergency Stop. And the other protection function pre-setting 2. Option: Smartgen HGM6110 Digital Auto Start 3. Option: Smartgen HGM6120 Digital Auto Start (Option assembled with the ATS) 4. Option: Deep Sea DSE5210 Digital Auto Start 5. Option: Deep Sea DSE5220 Digital Auto Start (Option assembled with the ATS) Digital Auto-start Generator controller integrating digital, intelligent and network techniques is used for automatic control system of diesel generator. It can carry out functions including automatic start/stop, data measure and alarming. Optionally assembled with the ATS, it can carry out auto-switching between the outer power and generating set power. (AMF) Functions: *Automatic Start/Stop *3 start attempts failure and Automatic Crank Disconnect *Parameters display (V/A/Hz/Hour) *Engine monitoring and protection *Charge alternator exciting and Charge alternator fail alarm *Running hour counting *Settings can be adjustable via key buttons on front panel |