Product Main

Quick Details

Rated Current: 360A
Rated Voltage: 400V
Rated Power: 200KW
Frequency: 50HZ
Speed: 1500RPM
Output Type: AC Three Phase
Model Number: JGC200GF
Brand Name: FD
Place of Origin: China (Mainland)
Engine Model: 6LTAA8.9-G2
Configuration: 4 cycle , 6 cylinders in line
Aspiration: Turbocharged after air-air cooled
Speed Governor: electrical
Fuel Consumption at 100% Load: 197g/kw.h
Alternator model: SV274
Exciter type: Single bearing, Brushless, Self-excited
Protection grade: IP23

Specifications

200KW Cummins Silent Diesel Generator for Sale

General feature

All qualified generator sets are subjected to a comprehensiveperformance test which includes 50% load, 75% load, 100%load, 110% load and to check, verify that all control systems,alarm and shut-down protection.Equipped with battery charger and 24V high performancemaintenance-free lead-acid starting batteries and connectingcables.Equipped with industrial silencer and flexible exhaust hose.

Equipped with 8-hours operation base fuel tank.

Equipped with PEOPLE MCCB circuit breaker.

Designed to Comply with ISO8528/GB2820.

Powered by Cummins engine and coupled with Marathonalternator.

Advantages

Stability, reliability and easy-service

Low operating and maintenance cost

Widely used, location to meet customer needs

Easy-installation, easy-operation and maintenance

Genset Technical Data

Prime power:200 kW

Standby power: 220 kW

Rated speed :1500 RPM

Output frequency :50 Hz

Phase :3

Rated voltage :400 V

Noise dB(A) @7m :100

Engine model :6LTAA8.9-G2

Alternator model :MP-200-4

Prime Power : Prime power is available for an unlimited number of

annual hours in variable load application, inaccordance with GB/T2820-97; A 10% overload capability is available for a period of 1 hour within a 12-hour periodof operation.

Standby Power Rating : The standby power rating is applicable for supplying emergency power for the duration of autility power interruption. No overload, utility parallel or negotiated outage operation capability is available at thisrating.

Reliable Performance

Voltage regulation

Voltage regulation maintained within ±0.5% as follow:

Power factor Between 0.81.0 lag

From no load to full load, any steady load

Speed droop variation under 4.5%

Frequency/Speed undulation

Change load from 0-100%, Frequency/Speed Droop Ratio within 5%

Load from 25-100%, any steady load Frequency/Speed undulation within 0.25%

Effect factor of telecom

Telephone Influence Factor (TIF) : Less than 50

THF : Less than 2%

Certificate

ISO8528, GB/T2820

EN12601:2001, EN60034-22:1997, EN60204-1:2006

ISO9001:2008 Quality Control System

CE

Dimension and Weight

Open Type

Overall size (L*W*H)

3590×1250×2050 mm

Weight: 2940kg

For reference only

ENGINE SPECIFICATION

Cummins Diesel Engine Technical Data

Engine Model 6LTAA8.9-G2

Configuration 4 cycle , 6 cylinders in line

Aspiration Turbocharged after air-air cooled

Bore×Stroke 114 x 144 mm

Rated speed 1500rpm

Displacement 8.9L

Compression Ratio 17.0:1

Prime Power 220KW

Speed Governor electrical

Cooling System

Water-cooled

Speed Stability (%) ≤5%

Fuel Consumption at 100% Load 197g/kw.h

Starter Motor DC24V,

Alternator SPECIFICATION

Marathon Alternator Technical Data

Alternator model SV274

Alternator manufacturer Sunvim

Exciter type Single bearing, Brushless, Self-excited

Rated output prime power 200kW

Rated speed 1500 RPM

Rated frequency 50 Hz

Phase 3

Rated voltage 400 V(Available with customer requirements)

Power factor 0.8

Voltage adjust range ≥5%

Voltage regulation NL-FL ≤±1%

Insulation grade H

Protection grade IP23

Control System

Control System HGM6110

All FENGDE gensets have a control cubicle (the smart gen HGM6110 as standard) mounted on a isolated support,which has the following features.

Electronic digital control module with monitoring/control facility and warning indicators

Automatic shutdown protection

Emergency stop button (lock-down type)

AC output circuit breaker with over-current protection

DC circuit control switch

The control module display

Generator voltage

Generator voltage

Output frequency

Engine speed

Battery voltage

Engine run-time (Hours)

 Note:

1. The engine coolant temperature displayed by water temperature gauge

2. The engine oil pressure displayed by oil pressure meter

3. Generator current displayed by current meter, to change switch for each phase displayed separately