Rated Current: | 360A |
---|---|
Rated Voltage: | 400V |
Rated Power: | 200KW |
Frequency: | 50HZ |
Speed: | 1500RPM |
Output Type: | AC Three Phase |
Model Number: | JGC200GF |
Brand Name: | FD |
Place of Origin: | China (Mainland) |
Engine Model: | 6LTAA8.9-G2 |
Configuration: | 4 cycle , 6 cylinders in line |
Aspiration: | Turbocharged after air-air cooled |
Speed Governor: | electrical |
Fuel Consumption at 100% Load: | 197g/kw.h |
Alternator model: | SV274 |
Exciter type: | Single bearing, Brushless, Self-excited |
Protection grade: | IP23 |
Quick Details
Specifications
General feature
All qualified generator sets are subjected to a comprehensiveperformance test which includes 50% load, 75% load, 100%load, 110% load and to check, verify that all control systems,alarm and shut-down protection.Equipped with battery charger and 24V high performancemaintenance-free lead-acid starting batteries and connectingcables.Equipped with industrial silencer and flexible exhaust hose.
Equipped with 8-hours operation base fuel tank.
Equipped with PEOPLE MCCB circuit breaker.
Designed to Comply with ISO8528/GB2820.
Powered by Cummins engine and coupled with Marathonalternator.
Advantages
Stability, reliability and easy-service
Low operating and maintenance cost
Widely used, location to meet customer needs
Easy-installation, easy-operation and maintenance
Genset Technical Data
Prime power:200 kW
Standby power: 220 kW
Rated speed :1500 RPM
Output frequency :50 Hz
Phase :3
Rated voltage :400 V
Noise dB(A) @7m :100
Engine model :6LTAA8.9-G2
Alternator model :MP-200-4
Prime Power : Prime power is available for an unlimited number of
annual hours in variable load application, inaccordance with GB/T2820-97; A 10% overload capability is available for a period of 1 hour within a 12-hour periodof operation.
Standby Power Rating : The standby power rating is applicable for supplying emergency power for the duration of autility power interruption. No overload, utility parallel or negotiated outage operation capability is available at thisrating.
Reliable Performance
Voltage regulation
Voltage regulation maintained within ±0.5% as follow:
Power factor Between 0.8~1.0 lag
From no load to full load, any steady load
Speed droop variation under 4.5%
Frequency/Speed undulation
Change load from 0-100%, Frequency/Speed Droop Ratio within 5%
Load from 25-100%, any steady load Frequency/Speed undulation within 0.25%
Effect factor of telecom
Telephone Influence Factor (TIF) : Less than 50
THF : Less than 2%
Certificate
ISO8528, GB/T2820
EN12601:2001, EN60034-22:1997, EN60204-1:2006
ISO9001:2008 Quality Control System
CE
Dimension and Weight
Open Type
Overall size (L*W*H)
3590×1250×2050 mm
Weight: 2940kg
For reference only
ENGINE SPECIFICATION
Cummins Diesel Engine Technical Data
Engine Model 6LTAA8.9-G2
Configuration 4 cycle , 6 cylinders in line
Aspiration Turbocharged after air-air cooled
Bore×Stroke 114 x 144 mm
Rated speed 1500rpm
Displacement 8.9L
Compression Ratio 17.0:1
Prime Power 220KW
Speed Governor electrical
Cooling System
Water-cooled
Speed Stability (%) ≤5%
Fuel Consumption at 100% Load 197g/kw.h
Starter Motor DC24V,
Alternator SPECIFICATION
Marathon Alternator Technical Data
Alternator model SV274
Alternator manufacturer Sunvim
Exciter type Single bearing, Brushless, Self-excited
Rated output prime power 200kW
Rated speed 1500 RPM
Rated frequency 50 Hz
Phase 3
Rated voltage 400 V(Available with customer requirements)
Power factor 0.8
Voltage adjust range ≥5%
Voltage regulation NL-FL ≤±1%
Insulation grade H
Protection grade IP23
Control System
Control System HGM6110
All FENGDE gensets have a control cubicle (the smart gen HGM6110 as standard) mounted on a isolated support,which has the following features.
Electronic digital control module with monitoring/control facility and warning indicators
Automatic shutdown protection
Emergency stop button (lock-down type)
AC output circuit breaker with over-current protection
DC circuit control switch
The control module display
Generator voltage
Generator voltage
Output frequency
Engine speed
Battery voltage
Engine run-time (Hours)
Note:
1. The engine coolant temperature displayed by water temperature gauge
2. The engine oil pressure displayed by oil pressure meter
3. Generator current displayed by current meter, to change switch for each phase displayed separately