| Rated Current: | 90A |
|---|---|
| Rated Voltage: | 220/400V |
| Rated Power: | 50KW |
| Frequency: | 60HZ |
| Speed: | 1800RPM |
| Output Type: | AC Three Phase |
| Model Number: | JGC50GF |
| Brand Name: | FD |
| Place of Origin: | China (Mainland) |
| Engine Model: | 4BTA3.9-G2 |
| Configuration: | 4 cycle , 4 cylinders in line |
| Aspiration: | Turbocharged after water-cooled |
| Bore*troke: | 102 x120 mm |
| Rated speed: | 1800rpm |
| Fuel Consumption at 100% Load: | 216g/kw.h |
| Alternator model: | MP-50-4 |
| Exciter type: | Single bearing, Brushless, Self-excited |
| Protection grade: | IP23 |
Quick Details
Specifications
General feature
All qualified generator sets are subjected to a comprehensive performance test which includes 50% load, 75% load, 100% load, 110% load and to check, verify that all control systems,alarm and shut-down protection.Equipped with battery charger and 24V high performance maintenance-free lead-acid starting batteries and connectingcables.
Equipped with industrial silencer and flexible exhaust hose.
Equipped with 8-hours operation base fuel tank.
Equipped with PEOPLE MCCB circuit breaker.
Designed to Comply with ISO8528/GB2820.
Powered by Cummins engine and coupled with Marathon alternator.
Advantages
Stability, reliability and easy-service
Low operating and maintenance cost
Widely used, location to meet customer needs
Easy-installation, easy-operation and maintenance
Genset Technical Data
Prime power :50 kW
Standby power :55 kW
Rated speed :1800 RPM
Output frequency :60 Hz
Phase: 3
Rated voltage: 220/400V
Engine model: 4BTA3.9-G2
Alternator model: MP-50-4
Prime Power : Prime power is available for an unlimited number of annual hours in variable load application, in accordance with GB/T2820-97; A 10% overload capability is available for a period of 1 hour within a 12-hour period of operation.
Standby Power Rating : The standby power rating is applicable for supplying emergency power for the duration of a utility power interruption. No overload, utility parallel or negotiated outage operation capability is available at this rating.
Voltage regulation
Voltage regulation maintained within ±0.5% as follow:
Power factor Between 0.8~1.0 lag
From no load to full load, any steady load
Speed droop variation under 4.5%
Frequency/Speed undulation
Change load from 0-100%, Frequency/Speed Droop Ratio within 5%
Load from 25-100%, any steady load Frequency/Speed undulation within 0.25%
Effect factor of telecom
Telephone Influence Factor (TIF) : Less than 50
THF : Less than 2%
Certificate
ISO8528, GB/T2820
EN12601:2001, EN60034-22:1997, EN60204-1:2006
ISO9001:2008 Quality Control System
CE
Dimension and Weight
Close Type
Overall size (L*W*H)
2440×1060×1680 mm
Weight: 1450kg
For reference only
ENGINE SPECIFICATION
Engine Model 4BTA3.9-G2
Configuration 4 cycle , 4 cylinders in line
Aspiration Turbocharged after water-cooled
Bore×Stroke 102 x120 mm
Rated speed 1800rpm
Displacement 3.9 L
Compression Ratio 16.5:1
Prime Power 60KW
Speed Governor electrical
Cooling System Water-cooled
Speed Stability (%) ≤5%
Fuel Consumption at 100% Load 216g/kw.h
Starter Motor DC24V,
Alternator SPECIFICATION
Alternator model MP-50-4
Alternator manufacturer Marathon
Exciter type Single bearing, Brushless, Self-excited
Rated output prime power 45 kW
Rated speed 1500 RPM
Rated frequency 50 Hz
Phase 3
Rated voltage 440 V(Available with customer requirements)
Power factor 0.8
Voltage adjust range ≥5%
Voltage regulation NL-FL ≤±1%
Insulation grade H
Protection grade IP23
Control System
Control System HGM6110
All FENGDE gensets have a control cubicle (the smart gen HGM6110 as standard) mounted on a isolated support,
which has the following features.
Electronic digital control module with monitoring/control facility and warning indicators
Automatic shutdown protection
Emergency stop button (lock-down type)
AC output circuit breaker with over-current protection
DC circuit control switch
The control module display
Generator voltage
Output frequency
Engine speed
Battery voltage
Engine run-time (Hours)
Note:
1. The engine coolant temperature displayed by water temperature gauge
2. The engine oil pressure displayed by oil pressure meter
3. Generator current displayed by current meter, to change switch for each phase displayed separately
The control module display for failure information
Overspeed / underspeed
Emergency stop
Low oil pressure
High water temperature
Failure to start
Battery charger failure
Automatic shutdown
Low engine oil pressure
High engine water temperature
Overspeed/underspeed
Failure to start after three attempts
Generator set options and Accessories
Generator set
Open generator set
Trailer generator set
Single phase generator set
ABB MCCB circuit breaker
Fuel system
12 hour base tank(single wall)
24 hour base tank(single wall)
Dual wall base fuel tank
Outside fuel tank
Exhaust system
Residential exhaust silencer
Alternator
PMG excitation
Space heater
Low environment temperature
Water heater
Oil heater
Battery heater
Control system
AMF function
ATS control cabinet
Multiple generator automatic synchrorising
FENGD r eserves the right to change the specifications and designs without notice .
WARNING:
Do not connect generator sets to any load and electrical equipments unless the circuit breaker in the disconnected condition.