Product Main

Quick Details

Model Number: FKJ-B(PWM)5KW96V
Brand Name: Deming
Place of Origin: China (Mainland)
Wind turbine rated power: 5KW
Wind turbine max. power: 10KW
Solar panel power: 1.5KW
Battery Bank Voltage: 96Vdc
Function: Rectifier,charge, control
Display mode: LCD
PWM constant pressure voltage: >116Vdc
3-phase load voltage of the wind turbine: 116Vdc
Wind turbine recovery charging voltage: 108Vdc
Low-voltage of the battery: 80Vdc

Specifications

Specifications
1.Equipped with external dump load 
2.LCD display 
3.Optional remote communication 
4.Certificates: CE & Patent 

 

Product Overviews

FKJ-B model Product Characteristics

1. The product can be manufactured in accordance with either JB/T6939.1-2004 industrial standard, GB/T19115.1-2003 national standard or users' technical requirements.

2. Adopt two sets of control systems, PWM constant pressure system and three-phase load discharging system.

3. PWM constant pressure control is 120% of the rated power of the wind turbine generator. In case of exceeding the scope of PWM constant pressure power, the three-phase load discharging will automatically start immediately to ensure safe operation of the overall wind turbine generation system.

4. Under the circumstances of decoupling and damage of the battery, the three-phase load discharging will automatically start to avoid the idle run of the wind turbine generator and the occurrence of runaway accident.

5. PWM control: Under the conditions of strong or super-strong wind, ensure battery charged by the wind turbine generator under constant voltage and current.

6. It has reverse connection, anti-decoupling and damage-resisting protection of the battery.

7. Over-charging protection of the battery: When the battery is full (the battery pressure reaching 125% of the rated pressure), the controller will automatically carry out three-phase load discharging to stop charging           battery.

8. Auto recovery of battery charging: When the battery pressure reduces to 108% of the rated pressure, the three-phase load discharger will stop load discharging to automatically recover battery charging.

9. The inside of the controller is equipped with lightening protection device. Contain the transit over voltage penetrating into the wind turbine generator within the voltage scope bearable to the equipment or system or conduct the strong lightening current into the earth to avoid equipment damage posed by lightening impact.

10. The big screen LCD display. Clearly present the working status of the wind turbine, solar panel, battery and controller.

11. The controller is equipped with manual three-phase load discharging switch; the user may use it according to actual circumstances. When using this switch, the wind turbine generator will forcibly carry out three-phase load discharging.

12. Optional communication Mode:RS232,RS485,GPRS,USB,RJ45 ect, Can monitor multiple devices running.

Technical Parameters of the FKJ-B (PWM) Off - Grid Wind Solar Controller 5KW

 

Type

5KW-48Vdc

5KW-96Vdc

5KW-240Vdc

Wind turbine rated power

5KW

5KW

5KW

Wind turbine max. power

10KW

10KW

10KW

Solar panel power

1.5KW

1.5KW

1.5KW

Battery

48Vdc

96Vdc

240Vdc

Function

Rectifier,charge, control

Display mode

LCD

Display content

Wind turbine voltage, wind turbine current, wind turbine power, solar panel voltage, solar panel current, solar panel power, battery voltage, charge current

PWM constant pressure voltage

>56Vdc

>116Vdc

>280 Vdc

3-phase load voltage of the wind turbine

58±1Vdc

116±2Vdc

290±5Vdc

Wind turbine recovery charging voltage

54±1Vdc

108±2Vdc

280±5Vdc

Solar controller stop charging voltage

58±1Vdc

116±2Vdc

290±5Vdc

Solar restore charge voltage

54±1Vdc

108±2Vdc

280±5Vdc

Low-voltage of the battery

40±1Vdc

80±2Vdc

200±5Vdc

Self-provided connecting wire of the battery

>20mm2

>10mm2

>6mm2

PWM fuse

125A

80A

40A

Solar fuse

32A

23A

10A

Charging fuse

160A

104A

50A

Work environment temperature

-30-60°C

Relative humidity

<90% No condensation

Noise (1m)

<40dB

Degree of protection

IP20(Indoor)

Cooling method

Forced air cooling

*Communication interface (optional)

RS485/USB/GPRS/Ethernet

*Temperature compensation(optional)

-4mv/°C/2V,-35°C~+80°C,

Accuracy:±1°C

Size of the controller

500*440*290 mm

Weight of the controller

21 Kg

Size of the load

660*510*450 mm

Weight of the load

31 Kg

 

*Above parameter only for reference

 

1. Could be custom made to user specifications. 2, Could have solar power control subject to user demand.