| Model Number: | R410a |
|---|---|
| Application: | R410A refrigerant gas is used in new residential and commercial air co |
| Purity: | 99.8 |
| MF: | CH2F2/CHF2CF3 |
| CAS No.: | 420-46-2 |
| Classification: | |
| Boiling Point (101.3KPa, ):: | -52.7 |
| Critical Temperature: | 72.5 |
| Critical Pressure (KPa): | 4964.2 |
Quick Details
Specifications
Refrigerant R410a Gas
Gas R410a is a new kind of refrigerant which is more friendly to the environment.
1. Specification:
|
Classification |
Alkyl & Derivatives |
|
CAS No. |
420-46-2 |
|
Purity: |
≥99.8% |
|
Payment Terms: |
L/C or 30% T/T |
|
Supply Ability: |
2000 Ton/Tons per Month |
|
Formula: |
CH2F2/CHF2CF3 |
|
Boiling Point (101.3KPa, ): |
-52.7 |
|
Critical Temperature (): |
72.5 |
|
Critical Pressure (KPa): |
4964.2 |
|
Density of saturated liquid (30°C): |
1.038g/CBM |
|
ODP: |
0 |
|
GWP: |
0.29 |
|
Molecular weight: |
72.58 |
|
Specific heat of liquid (30°C): |
1.78kJ/kg.K |
|
Specific heat of equal pressure steam (Cp) (30°C and 101.3KPa): |
0.85kJ/kg.K |
|
Vaporization Heat Under Boiling Point: |
256.7kJ/kg |
|
Moisture: |
≤10PPM |
|
Acidity: |
≤1PPM |
|
Residue on Evaporation: |
≤100PPM |
|
Critical Density: |
0.500g/CBM |
2. Package and Storage:
R410a refrigerant gas is packed disposable steel cylinder 11.3kg/25lb; recyclable steel
cylinder 800kg/926L.
Filling co-efficient is not more than 0.87kg/L.
Cylinders should be stored in cool, dry and ventilated place.
CE/DOT cylinders could be provided.
3. Applications:
R410A refrigerant gas is used in new residential and commercial air conditioning systems, heat
pumps, dehumidifiers and small chillers. R410A is also being considered in some medium
temperature refrigeration applications.
4. Properties & Performance:
R410a is a near-azeotropic HFC refrigerant blend that meets the industry's needs for many new
air conditioning systems. R410a has received an A1 safety rating from ASHRAE (lowest levels of
toxicity and flammability) having zero ozone depletion potential.
R410a is a higher pressure and capacity refrigerant than requiring equipment and components
specifically designed to accommodate the resulting higher system pressures and lower flow rates
needed. Typical operating pressures of an R410a system will be 50% to 60% higher than those in
an system at comparable operating conditions. R410a also has significantly higher volumetric
refrigerating capacity than under most operating conditions. This allows OEMs to manufacture
equipment of similar capacity and efficiency to in a smaller package.