| Tensile Strength: | 10.4 MPa |
|---|---|
| Application: | Low Voltage |
| Type: | Insulation Sleeving |
Quick Details
Specifications
| S2 Flexible Highly Flame Retardant Heat Shrink Tube | ||||
| Features | ||||
| Highly flame retardant VW-1(except clear) | Operating temperature: -40~125 ℃ | |||
| Excellent flexibility | Shrink temperature: 125 ℃ | |||
| Wide range of colors | Shrink ratio: 2:1, 3:1, 4:1 | |||
| Multiple shrink ratio available | RoHS compliant | |||
| Approvals | ||||
| UL approval | File No.: E236437 | |||
| Dimensions | ||||
| Reference | As supplied(mm) | After recovered(mm) | Standard length | |
| UPM S2 | ID min. | ID max. | WT nom. | m |
| Shrink Ratio: 2:1 | ||||
| 1.2/0.6 | 1.2 | 0.6 | 0.28 | 200 |
| 1.6/0.8 | 1.6 | 0.8 | 0.32 | 200 |
| 2.4/1.2 | 2.4 | 1.2 | 0.38 | 200 |
| 3.2/1.6 | 3.2 | 1.6 | 0.40 | 200 |
| 4.8/2.4 | 4.8 | 2.4 | 0.52 | 100 |
| 6.4/3.2 | 6.4 | 3.2 | 0.55 | 100 |
| 9.5/4.8 | 9.5 | 4.8 | 0.60 | 100 |
| 12.7/6.4 | 12.7 | 6.4 | 0.65 | 100 |
| 16.0/8.0 | 16.0 | 8.0 | 0.70 | 100 |
| 19.0/9.5 | 19.0 | 9.5 | 0.80 | 100 |
| 25.4/12.7 | 25.4 | 12.7 | 0.90 | 50 |
| 32.0/16.0 | 32.0 | 16.0 | 0.95 | 50 |
| 38.0/19.0 | 38.1 | 19.0 | 1.00 | 50 |
| 50.0/25.0 | 50.8 | 25.4 | 1.10 | 25 |
| 76.0/38.0 | 76.2 | 38.1 | 1.46 | 25 |
| 101.6/51.0 | 101.6 | 50.8 | 1.46 | 25 |
| Shrink Ratio: 3:1 | ||||
| 3/1 | 3.0 | 1.0 | 0.60 | 200 |
| 6/2 | 6.0 | 2.0 | 0.70 | 100 |
| 9/3 | 9.0 | 3.0 | 0.80 | 50 |
| 12/4 | 12.0 | 4.0 | 0.85 | 50 |
| 15/5 | 15.0 | 5.0 | 1.00 | 50 |
| 18/6 | 18.0 | 6.0 | 1.00 | 25 |
| 24/8 | 24.0 | 8.0 | 1.20 | 25 |
| 30/10 | 30.0 | 10.0 | 1.20 | 25 |
| 39/13 | 39.0 | 13.0 | 1.25 | 1/1.22 |
| 51/17 | 51.0 | 17.0 | 1.40 | 1/1.22 |
| Shrink Ratio: 4:1 | ||||
| 4/1 | 4.0 | 1.0 | 0.75 | 100 |
| 8/2 | 8.0 | 2.0 | 0.90 | 50 |
| 12/3 | 12.0 | 3.0 | 1.10 | 1/1.22 |
| 16/4 | 16.0 | 4.0 | 1.20 | 1/1.22 |
| 24/6 | 24.0 | 6.0 | 1.50 | 1/1.22 |
| 32/8 | 32.0 | 8.0 | 1.50 | 1/1.22 |
| 36/9 | 36.0 | 9.0 | 1.80 | 1/1.22 |
| 52/13 | 52.0 | 13.0 | 2.50 | 1/1.22 |
| Technical Data | ||||
| Property | Test method | Values | ||
| Physical | Tensile strength | When test at 500mm/min. | ≥10.4 MPa | |
| Breakdown elongation | When test at 500mm/min. | ≥ 200% | ||
| Aging(158 ℃/168hrs) | Tensile strength | When test at 500mm/min. | ≥ 7.3 MPa | |
| Breakdown elongation | When test at 500mm/min. | ≥ 100% | ||
| Density | -- | 1.15-1.25 | ||
| Thermal endurance | -- | 125℃ | ||
| Heat shock | 4hrs. at 250℃ |
No cracking, drop or flow |
||
| Cold bend | 1 hour at -30℃ | No cracking | ||
| Water absorption( 23℃/24hrs) | -- | ≤0.5% | ||
| Eletrical | Dielectric breakdown voltage | -- | ≥ AC 2500V | |
| Dielectric voltage Withstand | 1min.AC2500V | No breakdown | ||
|
Aging (158 ℃/168hrs) |
Dielectric breakdown voltage | -- |
AC 2500V min. and more than 50% of the value obtained with unaged sample |
|
| Dielectric voltage Withstand | 1min.AC2500V | No breakdown | ||
| Volume resistivity | -- | ≥1014 Ω.cm | ||
| Chemical | Copper stability | 168h at 158℃ 500mm/min. | Elongation≥100% | |
| Flammability | VW-1 | UL224 | ||
| Note: The test methods conform to UL224. | ||||
| ID=Internal Diameter | WT=Wall Thickness | |||
| Typical application | ||||
| Ideal for protecting and bundling of small harnesses, insulation of in-line splices, strain relief | ||||
| of wire connections, and color-coding wires, cables, terminals and electronic components | ||||
| Ordering | ||||
| Standard color : Red, Blue, Yellow,White, Black, Green, Clear | ||||
| Special colors are available on request | ||||
| Standard packaging on spools and/or 1.22m/pc,1 m/pc | ||||
| Please specify specification, color, quantity when ordering | ||||
| Cross reference | ||||
| Raychem/ Tyco : Versafit | ||||