Rated Current: | 12.5 |
---|---|
Rated Voltage: | 400 |
Rated Power: | 5KVA |
Frequency: | 50 |
Speed: | 1500 |
Output Type: | AC Three Phase |
Model Number: | KS6700T3-A |
Brand Name: | Kusing |
Place of Origin: | China (Mainland) |
Engine: | 192fe |
Fuel Tank: | Bsae for 8 Hours Continuous Running |
Structure Mode: | Trolly |
Quick Details
Specifications
1. KUSING diesel generator sets comply with the newest national and international standard.
2. The diesel engines KUSING use are famous brand with high quality, such as CUMMINS, VOLVO, ISUZU, LOVOL, YTO, YANGDONG, SDEC, etc; All of them have a 4-stroke, direct injection system, electric start mode and water-cooling system; They will make the generator sets work more economically, reliably and durably.
3. The alternators KUSING use are also famous brand with high quality, such as MARTHON, LEROY SOMER, STAMFORD, EVO-TEC ENGLA etc; They are brushless, self-excited and 4 single-bearing structure with protection grade IP21-IP23 and insulation class H.
4. KUSING silent type generator sets will be mounted with a canopy; It is designed by us with the advanced soundproof technology, which can greatly reduce the noise level to 60-70dB(A) or even lower.
5. The industrial silencer system of KUSING works highly efficiently.
6. A seperated plastic fuel tank is equiped inside the generator, which can keep the fuel fine and safe.
7. All the KUSING generator sets have a anti-vibrated system.
8. The multi-functional LED controller with MFC make the operation of generator set more easily and safely.
9. If a ATS(Automatic Transfer Switch) is mounted, the generator set can running without operation by hand and charge battery by normal power.
10. The output of KUSING generator sets range from 10KVA to 2000KVA.
Generator | Model | KS6700T3-A | Three |
|
Three | single | |
Rated Frequency(Hz) | 50 | 50 | |
Rated Power(KVA) | 6 | 6 | |
Rated Rotation Speed(rpm) | 3000 | 3000 | |
Rated Voltage(V) | 230/115 | 400/230 | |
Rated DC Output(V/A) | 12/8.3 | ||
Power Factor cosφ | 1 | 0.8(LAG) | |
Excitation System | Controllable self-excitation and constant voltage | ||
Structure | Trolley | ||
Engine | Engine Model | 192FE | |
Engine Type | single-cylinder,vertical,4-stroke,forced air cooled,direct-injection | ||
Starting system | electric starter | ||
Fuel Tank capacity(L) | 16 | ||
Noise Level(at 7m)db(A) | 75 | ||
Packing | N.W/G.W(KG) | 185/193 | |
Dimension (L×W×H) | 940×540×860 | ||
20FT(set) | 48 |
service, regular return visit and permanent maintenance.
Power generator use of safety norms:
1.Operators sould be familiar with the operation of generating units, operating methods, and all control bodies, manual valves, stopping body position.
the engine room or near the unit, must hoisting of danger notices warning signs associated personnel:
(1)Uints exist electric shocks danger;
(2)Uints exist scald danger;
(3)Units exist winding, and collision dangers;
3.To avoid fuel, lubricants, and other fire, engine room No smoking.
4.Engine room or other nearest shouldmaintain an appropriate level of fire service equipment (proposed CO2 fire extinguishers).
5.Grounding the entire unit reliably, and meet the applicable requirements of neutral grounding.
6.Above and around the unit should not be unrelated equipment, obstructions and dangerous goods, should be keeping the floor dry and clean without oil.
7.Units will be run by noise, suggest that the staff wear suitable protective equipment, such as earmuffs vehicles.
8.Before any maintenance, must cut off all power lines, particularly the Dcpower supply circuit (remove the battery's anode and cathode), the warning signs must also note "is maintenance", and should have another concern, especially in the narrow region maintenance at the same time should be nitified stop all of this unit operation.
9.To the reliable operation of unit, the settings of unit voltage, frequency, speed and other related parameters and unit controller set up should not be arbitrarily changed except the specialized operators.
10.Units are valuable equipment, for personal safety, operation stability to light, no illegal operation and drink operation.