| Model Number: | 5E-PL300B |
|---|---|
| Brand Name: | CKIC |
| Place of Origin: | China (Mainland) |
Quick Details
Specifications
We are the unique
The Determination of plastometric indices of bituminous coal is to determine maximum thickness of plastic layer Y and final contraction value X when coal is heated at a specified heating rate. X value can be used as a guidance to the safety of the coking oven, Y value is the key parameter in coking coal blending. What's more, Y value can be used as a reference to the coke ability and to determine the coal rank.
Standard configuration
1.Computer 2.Printer 3.Coal cup 4.Pressure set 5.Thermocouple Tube 6.Heating Element set
7.Probe set 8.Cushions for Coal cup 9.Filter paper for Coal cup 10.Paper for Steel needle
11.Displacement Sensor 12.Pressure Sensor 13.Steel Needle 14.Thermocouple
Features
Full-automatic Test Process
1. Temperature controller provides temperature rise curve based on GB standard.
2. The rolling paper is automatically aligned with probe, which improves the stability and accuracy of measurement as well as ease-of-use.
3. All loading and removing of weights are controlled by the intelligent system, greatly reducing labor intensity and simplifying operation.
4. Volume sensor is automatically loaded and removed to enhance stability of a measurement.
5. The change of sample volume and plastic layer will be automatically recorded to form curve.
6. The intelligent manipulator measures the curve of upper and layer to get the maximum thickness Y.
Cost Saving
Integrated smoke exhaust system ensures the test is performed without external fume cupboard.
Improved Safety
1. Interlock Features. High-voltage parts are designed with isolated protection.
2. Equipped with the functions of power-off protection and monitoring.
| Model | 5E-PL300B Automatic Plastmetric Indices Determinator |
| Conforms to Method | GB/T479 |
| Temperature Controlling Range | Ambient Temp. - 800℃ |
| Temperature Controlling Precision | ≤ 250℃, ±10℃, 250℃~730℃(±3℃) |
| Heating Rate | ≤ 250°C 8°C/min, >250°C 3°C/min |
| Volume Sensor Precision | 0.05% |
| Pressure Sensor Precision | 0.02%FS ( full scale) |
| Accuracy of Displacement Sensor | 0.02% |
| Repeatability | ≤ 1mm if Y ≤ 20mm, ≤2mm if Y > 20mm; X≤ 3mm |
| Working Conditions | 1.Ambient Temperature:(5~40)℃ |
| 2.Relative Humidity(RH):(20~85)% | |
| 3.No strong vibration, air flow, erosive gas and EMI | |
| Power Supply | Single phase, AC220±10%, 50/60Hz, >5kW |
| Net Weight | 172KG |
| External Dimensions(mm) | 860×640×950 |