TC-2U40 (400W)
Safety Approval
Standard 2U dimension
Meet CE Rohs 2.0 2011/65/EU
Safety Approval
Standard 2U dimension
Meet CE Rohs 2.0 2011/65/EU
1.Model: TC-2U40
2.Watts: 400W
3.Input:
VOLTAGE: 90~135VAC or 185~260VAC (115/230 auto select)
FREQUENCY: 50/60Hz
INPUT CURRENT: 8A for 115VAC, 4A for 230VAC
INRUSH CURRENT: 60A for 115VAC, 80A for 230VAC MAX.
VOLTAGE: 90~135VAC or 185~260VAC (115/230 auto select)
FREQUENCY: 50/60Hz
INPUT CURRENT: 8A for 115VAC, 4A for 230VAC
INRUSH CURRENT: 60A for 115VAC, 80A for 230VAC MAX.
4.Output:
| Voltage: |
+5V DC
|
+12V DC
|
-5V DC
|
-12V DC
|
+3.3V DC
|
+5VSB
|
| Maximum Load: |
40A
|
20A
|
0.3A
|
0.8A
|
20A
|
2A
|
| Minimum Load: |
3A
|
2A
|
0.1A
|
0.1A
|
0.3A
|
0.1A
|
| Ripple/Noise Max.(P-P): |
50mv
|
120mv
|
150mv
|
150mv
|
50mv
|
50mv
|
| Line Regulation: |
±1﹪
|
±1﹪
|
±1﹪
|
±1﹪
|
±1﹪
|
±1﹪
|
| Load Regulation: |
±5﹪
|
±5﹪
|
±10﹪
|
±10﹪
|
±5﹪
|
±5﹪
|
◎ FEATURES:
* 2U Single.
* Auto Select AC input.
* Efficiency: ≧ 70﹪at full load.(Nominal Line)
* Hold-Up Time: 16ms at maximum load & normal input voltage.
* OVER VOLTAGE PROTECTION.
* SHORT CIRCUIT PROTECTION.
* OVER POWER PROTECTION.
* NO LOAD OPERATION.
* ENVIRONMENT TEMPERATURE
Operation Temperature: 0℃ to 40℃
Cooling: By forced air
Storage Temperature:-20℃ to 70℃
Humidity: 5 to 90﹪non-condensing.
* RELIABILITY
MTBF OF POWER SUPPLY ELECTRONIS
MTBF OF POWER SUPPLY ELECTRONIS
100,000 hours at full load and 25℃ ambient temperature
LIFE EXPECTANCY OF FAN
40,000 hours at 40℃
5.Dimensions:
L x W x H: 200 x 100 x 70 (mm) / 7.87 x 3.94 x 2.75 (inches)