Place of Origin: | China (Mainland) |
---|---|
Model Number: | E5 |
Brand Name: | BAICHENG |
Type: | ECG machine |
Quick Details
Specifications
Main Features:
1. 12 leads
simultaneous acquisition electrocardiograph
2. 3 channels printout on 80mm
wide thermal paper.
3. It works in manual or automatic mode with the
possibility to have a hard copy of the last recording.
4. Powered by
internal Li-ion batteries with high capacity which guarantee a long
autonomy.
5. Large screen color LCD and Touch-screen
6. High resolution
graphic LCD DISPLAY in Standard or Cabrera format with baseline setting
7.
HIGH RESOLUTION THERMAL PRINTER (8 dots/mm): Hardcopy 3 channels real
time
8. RECORDING manual or automatic
9. MEMORY 60 seconds for each
lead
10. IMAGE FREEZE with memory scrolling for reviewing and hardcopy of
the acquired signals
11. DIGITAL FILTERS for elimination of muscles tremors,
power line and base line disturbs and baseline wandering
12. OPERATION very
simple through predefined fast keys, patient ID and name input
13. Based on a
32 bits RISC PROCESSOR for a full digital signal
processing.
Power Supply |
100-120V or 220-240V, 50/60Hz or internal rechargeable battery with lifetime of 60 minutes |
Safety |
Class I, type CF |
LCD display |
Backlit high resolution 480 x 800 7 inch touchscreen display 12 channel ECG waveform simultaneously |
Leads |
12 STANDARD or CABRERA leads |
Defibrillation protection |
Internal, according to current regulations |
Recording modes |
Manual, automatic sequential, automatic simultaneous, Rhythm lead selectable |
Print Channels |
3 channels, Rhythm lead selectable |
Writing system |
High-resolution thermal printer (8 dots/mm); Horizontal 40 dots/mm |
Thermal paper |
80mm wide 20M thermal paper in Z-fold packers or in rolls |
Paper speed |
5 - 6.25 - 10 - 12.5 - 25 - 50mm/s ± 3% |
Paper size |
80mm/18m roll type or Z-fold thermal paper |
Recording sensitivity |
Auto or Manual: 1.25 - 2.5 - 5 - 10 - 20 - 40mm/mV ±3% |
Input dynamics |
±500 mV @ 0 Hz ± 10 mV in the pass band |
Input impedance |
50 MΩ DC |
Power requirements |
AC220V/50Hz |
Common-mode rejection |
> 90 dB |
Frequency response |
0.05 to 150 Hz |
Time constant |
>3.3 s |
Data acquisition |
12 bits; 1000 samples/sec/channel when printing, filtering and computing |
Fuse Specification |
2Φ5x20mm |
Case storage |
150 cases at least, can be stored on external SD card |
Patient Cable |
standard 10 leads |
Resolution |
3.125 uV/bit |
Filters |
Low pass filter off 75 Hz, 100 Hz, 150 Hz |
Muscle filter: 25 or 35 Hz digital filters (-3 dB/oct) |
|
AC filter: digital notch filters 50 or 60 Hz selectable, - 20 dB or better |
|
Drift filter: 0.5 Hz high pass linear phase digital filter |
|
Dimension |
285(W)*200(D)*50mm(H) 11.2" x 7.87"x 2.16" (inch) |
Patient ID input |
Yes |
Net weight |
2.1kg (4.63 lb) |
Gross weight |
3.6 kg (7.93 lb) |