Coil Number: | underwater toroidal transformers |
---|---|
Coil Structure: | Toroidal |
Phase: | Single |
Usage: | outdoor LED lighting,pool light,swimming pool lighting |
Model Number: | GWE-200A |
Brand Name: | Grewin Transformer |
Usage:: | underwater LED lighting,pool light,swimming pool lighting |
voltage transformer:: | 105va 150va 200va 300va 400va 500va 600va 1kva |
output:: | 24v 36v 12v ac |
type:: | power 200va 230-240vac 24vac AC-AC transformator |
Protection Grade:: | IP64 IP666 |
Annular core::: | Cold rolling directional silicon steel |
toroidal Transformer's materials:: | Insulation protection: Mylar |
Lead: UL WIRE: | Potted resin: Potted resin |
Standard conditions:: | ) IEC 61558-2-6:09 |
Thermal Fuse A7-5A-F 5A 138 degree: | double insulated |
Quick Details
Specifications
Name :
220v 24v 500va toroidal waterproof transformer with constant voltage
Certification:
1.We have abtained VDE,UL,CE,ROHS,ISO9000 Approal and SGS Audit Supplier in China,
We guarantee quality is the first:
220v 36v 24v toroidal transformer winding machine for underwater LED; 105VA 350va 700VA ac plug toroidal transformer for swimming pool; 105VA 350va 700VA ac plug toroidal transformer for swimming pool
waterproof Transformer's Dimension Sheet:
(Note:Rated 105VA-1000VA for devices 105VA-1000VA watts or less,
GWET-105 means 105VA size )
Waterproof toroidal Transformer's Spcification:
1).WORKING AND SAFETY PROTEETION
Eiectrostatic Shield Magnetic Shield
√ TemperatureProtection OverCurrent Protection
2).INSULATION
Insulation resistance test(type test):Pri.~sec. 500V DC 100 MΩMIN.
HI-POT TEST(100% test):Pass ourdielectric strength test, without any breakdown
Pri.~sec. AC 3.8kV for 5 seconds (leakage current 5mAMAX)
3).TEMPERATURE RISE
Ta=25℃Test by resistance method At rated load
PRI.& SEC. WINDINGS'TEMPERATURE RISE 75℃MAX.
4).MAJOR MEASUREMENT FACILITIES:
HI-POT TESTER: CJ2670
INSULATION-RESISTANCE METER: ZC-7
VOL TMETER: T19-V
DC-RESISTANCE METER: QJ44
AMPEREMETER: T19/1-A
5). MAIN PARAMETERS:
Input Voltage:AC 220V 230v 110v (Define the voltage)
Output voltage:AC 12V / 24V (Define the voltage)
Power range:105VA-1KVA
6) Waterproof toroidal Transformer's materials:
* Annular core: Cold rolling directional silicon steel
* Insulation protection: Mylar
* Core Insulation: Polyester 7C
* Primary/Secondary Winding: Enamelled copper wire
* Terminal cannula: PVC canula
* Termial uderlay: Polyester 19C
* Temperature Protection: Thermal Switch
* Pri.Insulation: Polyester 7C
* Insulation protection: Mylar
* Coating insulation: Polyester 5C
* Lead: UL WIRE
* Potted resin: Potted resin
* Body: PP+GFRP
7)Standard conditions and components:
* Transformer should meet " Short-circuit-proof safety isolating transformer (inherently
or non-inherently) IEC 61558-2-6:09"
* Thermal Switch 17AM 211 120°C Sensata Technologies or equivalent (UL E15962)
* Thermal Fuse A7-5A-F 5A/138°C Aupo Electronics or equivalent (UL E140847)
* Transformer is double insulated (Class II) with Insulation Class B 120°C
* Insulation tests 500VDC 100M ohm min and 4kV for 5 seconds at 5mA max leakage current
contact: salesmanager(at)
220v 24v 500va toroidal waterproof transformer with constant voltage
Certification:
1.We have abtained VDE,UL,CE,ROHS,ISO9000 Approal and SGS Audit Supplier in China,
We guarantee quality is the first:
220v 36v 24v toroidal transformer winding machine for underwater LED; 105VA 350va 700VA ac plug toroidal transformer for swimming pool; 105VA 350va 700VA ac plug toroidal transformer for swimming pool
waterproof Transformer's Dimension Sheet:
(Note:Rated 105VA-1000VA for devices 105VA-1000VA watts or less,
GWET-105 means 105VA size )
Waterproof toroidal Transformer's Spcification:
1).WORKING AND SAFETY PROTEETION
Eiectrostatic Shield Magnetic Shield
√ TemperatureProtection OverCurrent Protection
2).INSULATION
Insulation resistance test(type test):Pri.~sec. 500V DC 100 MΩMIN.
HI-POT TEST(100% test):Pass ourdielectric strength test, without any breakdown
Pri.~sec. AC 3.8kV for 5 seconds (leakage current 5mAMAX)
3).TEMPERATURE RISE
Ta=25℃Test by resistance method At rated load
PRI.& SEC. WINDINGS'TEMPERATURE RISE 75℃MAX.
4).MAJOR MEASUREMENT FACILITIES:
HI-POT TESTER: CJ2670
INSULATION-RESISTANCE METER: ZC-7
VOL TMETER: T19-V
DC-RESISTANCE METER: QJ44
AMPEREMETER: T19/1-A
5). MAIN PARAMETERS:
Input Voltage:AC 220V 230v 110v (Define the voltage)
Output voltage:AC 12V / 24V (Define the voltage)
Power range:105VA-1KVA
6) Waterproof toroidal Transformer's materials:
* Annular core: Cold rolling directional silicon steel
* Insulation protection: Mylar
* Core Insulation: Polyester 7C
* Primary/Secondary Winding: Enamelled copper wire
* Terminal cannula: PVC canula
* Termial uderlay: Polyester 19C
* Temperature Protection: Thermal Switch
* Pri.Insulation: Polyester 7C
* Insulation protection: Mylar
* Coating insulation: Polyester 5C
* Lead: UL WIRE
* Potted resin: Potted resin
* Body: PP+GFRP
7)Standard conditions and components:
* Transformer should meet " Short-circuit-proof safety isolating transformer (inherently
or non-inherently) IEC 61558-2-6:09"
* Thermal Switch 17AM 211 120°C Sensata Technologies or equivalent (UL E15962)
* Thermal Fuse A7-5A-F 5A/138°C Aupo Electronics or equivalent (UL E140847)
* Transformer is double insulated (Class II) with Insulation Class B 120°C
* Insulation tests 500VDC 100M ohm min and 4kV for 5 seconds at 5mA max leakage current
contact: salesmanager(at)