| Brand Name: | DK photo |
|---|
Quick Details
Specifications
Cladding Power Stripper
Cladding Power Stripper is use in high-power fiber lasers and amplifiers need to be able to handle substantial optical powers. It needs to be ensured that these powers are absorbed in a sufficiently widespread region, and that the generated heat can be removed safely, without damaging the mode stripper or any surrounding parts.
In fiber laser, the pump energy is absorbed along with doped fiber, transforming into signal energy, but pump cannot be absorbed completely, the residual part in outer cladding is no need, even dangerous for downstream components, with CPS can effectively "strip off" residual pump and signal which transmit back in clad, meantime keep the amplified signal unaffected.
We can provide CPS with all kind of Double Clad fiber,cladding power up to 300W. If you do not see a standard CPS that meets your needs, we welcome the opportunity to review your desired specification and quote a custom CPS. Requests for custom fiber type, different wavelengths and handling power of operation or other specific needs will be readily addressed.
|
Features |
Applications |
|
· Low Insertion Loss · High Power Handling · High Isolation · Low Cost · High Reliability · Excellent Temperature Stability |
· Fiber optic Amplifiers · Pump Laser Source · Fiber optic Sensor · Test and Measurement · Instrumentation |
Performance Specifications
|
Parameters |
Values |
|
Center Wavelength(nm) |
1030,1064,1080 |
|
Operating Wavelength-Pumps(nm) |
800~1200 |
|
Cladding attenuation(min)(dB) |
15 |
|
Max. Insertion Loss (at 25℃) (dB) |
0.30 |
|
Min. Polarization Extinction Ratio (dB) |
18(For PM Fiber) |
|
Cladding Power Handling(W) |
10, 20, 30 |
|
Fiber Type In/Out |
Double Clad fiber |
|
Pigtail Length(m) |
0.8 or other |
|
Operation Temperature(℃) |
0 ~ +50 |
|
Storage Temperature Range(℃) |
-20 ~ +75 |
General Configuration for CPS:
|
Working Wavelength(nm) |
Input/ouput Fiber |
Signal IL |
Min.Stripping Efficiency |
Max.Power Stripping |
|
1020~1080 |
6/125 DC |
≤0.3dB |
20dB |
50W |
|
1530~1570 |
8/125 DC |
≤0.3dB |
20dB |
50W |
|
1020~1080 |
10/125 DC |
≤0.3dB |
20dB |
50W |
|
1020~1080 |
12/125 DC |
≤0.3dB |
20dB |
50W |
|
1020~1080 |
15/125 DC |
≤0.3dB |
20dB |
50W |
|
1020~1080 |
20/125 DC |
≤0.3dB |
20dB |
10W |
|
1020~1080 |
20/200 DC |
≤0.3dB |
20dB |
50W |
|
1020~1080 |
25/250 DC |
≤0.3dB |
20dB |
200W |
|
1530~1570 |
25/300 DC |
≤0.3dB |
17dB |
50W |
|
1020~1080 |
30/250 DC |
≤0.3dB |
20dB |
300W |
|
1020~1080 |
20/400 DC |
≤0.3dB |
17dB |
500W |
|
1020~1080 |
PM6/125 DC |
≤0.3dB/ER>18dB |
20dB |
50W |
|
1020~1080 |
PM10/125 DC |
≤0.3dB/ER>18dB |
20dB |
50W |
|
1020~1080 |
PM15/125 DC |
≤0.3dB/ER>18dB |
20dB |
50W |
|
1020~1080 |
PM20/125 DC |
≤0.3dB/ER>18dB |
20dB |
50W |
|
1020~1080 |
PM20/200 DC |
≤0.3dB/ER>18dB |
20dB |
100W |
|
1020~1080 |
PM25/250 DC |
≤0.3dB/ER>18dB |
20dB |
300W |
|
1020~1080 |
PM30/250 DC |
≤0.3dB/ER>18dB |
20dB |
300W |
|
1020~1080 |
PM20/400 DC |
≤0.3dB/ER>18dB |
17dB |
500W |
Remark:
1.Other configuration can be customized.We can build CPS on every double clad fiber,
2.For handling power≥100W and some small core fiber CPS, will need water cooling.
3.All CPS default with bare fiber,0.8m length of pigtail, please contact us for special request.