Product Main

Quick Details

After-sales Service Provided: Engineers available to service machinery overseas
Certification: ASME,TUV,CE,SGS
Weight: according to the model
Dimension(L*W*H): according to the model
Output: Steam
Model Number: WNS
Brand Name: Wilford
Place of Origin: China (Mainland)
Fuel: Coal-fired
Style: Horizontal
Pressure: Low Pressure
Structure: Fire Tube
Usage: Industrial
Type: Natural Circulation
Condition: New
Safe: yes
Rated voltage: 3N AC 380V 50Hz
Keyword: horizontal steam boiler
Working pressure: 0.7Mpa(7bar)
rated evaporation: 0.5/h-20t/h
processing type: water
type of fyel: Oil/Gas/Diesel/Natural Gas
steam temp: 170-193dgr
warrantly: one year
type of boiler: diesel steam boiler

Specifications

 

WNS horizontal wet back steam boiler: 
|     Sweeping function after preset can improve working conditions of burner and extend its service life.

|     The unique design of the large burning chamber can increase the radiation of hearth heating area and reduce the volume of the boiler and NOx emissions;

|     Smoke pipes box around boiler uses multi-level sealing approaches, which is easy for maintenance of the smoke box;

|     Horizontal structure has area ample heated and adequate heat transfer, the boiler is stable in running when load changes, and combustion efficiency is high. Furnace pipe is arranged low with a large range of water level safety. Steam evaporation surface is large, with high quality steam.

|      It is equipped with advanced touch screen controller, digital prosecution system to achieve automatic control of boiler operation, with a variety of alarm interlock devices to ensure efficient, safe, reliable operation of the boiler.

 Technical Parameter

 

WNS Oil Gas Steam Boiler

Type

0.5

1

1.5

2

3

4

Project

           

Rated evaporation(t/h)

0.5

1

1.5

2

3

4

Rated working pressure(MPa)

0.7

1.0

1.0

1.0

1.0

1.25

Rated steam temperature()

170

184

184

184

184

193

Fuel consumption

(Nm 3/h)

Light diesel oil

35

70

105

140

210

260

Natural gas

40

80

120

160

240

280

Liquefied gas

15

30

45

60

90

120

Pipeline gas

85

170

250

340

510

680

Main steam valve diameter(DN)

40

65

65

80

80

100

Safety valve diameter(DN)

40

50

50

40 ×2

40 ×2

50 ×2

Infall diameter(DN)

25

25

40

40

40

50

Overall size(mm)

L

3800

4500

4700

4800

5500

6310

W

1900

2500

2800

2900

2900

2950

H

2100

2680

2950

3250

3880

3120

Steam boiler weight(T)

3.3

4.6

5.8

7.1

9.2

11

 

How to use boiler?

1.Built a boiler house.

2.Preparing piping as boiler technical data. 
3.Preparing electricity as required.
4.Installed boiler as manual.
5.Commissioning boiler as manual.
6.Operating boiler.