Quick Details

Rated Current: 2804A
Rated Voltage: 3kV-11kV
Rated Power: 1500kW
Frequency: 50Hz
Speed: 1500rpm
Output Type: AC Three Phase
Model Number: HGM1875HV
Brand Name: Googol
Place of Origin: China (Mainland)
Engine: Googol QTA3240G6
Akternator: Marathon MXH-1620-4
Controller: Deep Sea
Application Area: Industry project, hospital, hotel, etc
Optional: ATS, Silent Canopy, Water&Oil heater, etc
Certificates: CE, ISO, SGS, TUV, etc
Warranty: 1 year or 1000 working hours

Specifications

50Hz 1500kW Googol High Voltage Diesel Generator 3kV-11kV

Engine Datasheet : 

 

Engine Model   QTA3240-G6 /QTA53-EG6
Speed  rpm 1500
Frequency  Hz 50
 Rating Output    
Standby Output (LTP) kW 1802 
Prime Output (PRP) kW 1644 
Engine Continuous Power (COP) kW 1486 
Typical Generation Prime Output kVA 1875 
Typical Generation Prime Output kW 1500
Typical  Alternator Efficiency  95.0%
Voltage of Genset V 480
MECC alte Generator's Model   ECO46-1.5S/4
MARATHON Generator's Model   MX-1350-4
Basic Performance Datasheet    
Aspiration Type   Turbocharger, air-water aftercooler
Injection Type   Direct Injection
Configuration   Vee
No. of Cylinders   12
Displacement  l 53.1
Bore  mm 170
Stroke  mm 195
Compression Ratio   13.5:1
Fuel System    
Governor Type   Electrical 
Engine Output at genset prime output kW 1644 
Fuel Consumption at 75% of genset prime output l/h 299.09 
Fuel Consumption at 100% ofgenset prime output l/h 394.84 
Lowest Fuel Consumption Ratio g/kW.hr 200.55 
Intake & Exhaust System(On Standby Output)    
Combustion Air Consumption  m3/min 176.67 
Max. Intake Restriction  KPa 2
Exhaust Temperature (Before Turbo) °C 600
Exhaust Temperature (After Turbo) °C 480
Electrical System    
Charging Alternator Voltage  V 28
Charging Alternator Capacity  A 55
Starting Voltage V 24
Starting Motor Capacity  kW 13
Minimum Battery Capacity  Ah 4*200
Engine Dimension    
Length  mm 3096
Width  mm 1459
Height  mm 1820
Engine Dry Weight w/o Cooling System kg 5100

 

 

 

Performance Feature

Engine and alternator shall be mounted on a same frame steel skid.  

Built-in damper for anti-vibration.

World most famous brand diesel engine.

World famous brand AC alternator.

Advanced and reliable control module

Full range protection function and alarm shutdown feature.

  

Alternator Feature

Brush-less, 4 poles, rotation magnet.

IP21-23(NEMA1) enclosure is standard for all industrial alternators.

The insulation system is Class H

Simple installation and maintenance, with easy access to terminals, rotating diodes and coupling bolts.

Wide range of flange adaptors and single bearing disc coupling.

Standard 2/3 pitch windings avoid excessive neutral currents

AVR auto voltage regulator, auto exciter, auto adjustment

  

Standard Accessory 

Common steel base frame, Damper, Exhaust silencer, Flexible pipe, Battery and connecting wires, Operation manual and document.

  

Optional Accessory

Engine coolant and oil heater, Alternator space heater, Cooling for heat exchanger, Control system with RS232/485 communication interface, Battery charger by main supply, Fuel-water separator, Daily fuel tank, ATS & paralleling system, and Moving Trailer.

 

Silent Canopy Description

Standard Accessory:

Steel Weatherproof Canopy

Built In Fuel Tank For 8 Hours Running

Built In Control Panel

Built In Start Battery

Power Output Rapid Insert 

Windows for Looking

Air Louver for Intake & Exhaust

Exhaust Gas Silencer

Soundproof Type

 

Quality Warranty Period:

 All equipment is guaranteed for a period of 1000 hours running or 12 months from the date when the generator set has been delivered from the factory.

 

ATS SYSTEM

     For emergency power usage in building, Auto transfer switch (ATS) is essential. ATS can automatic transfer load from Mains power supplying to Emergency power. In normal, when the Main power supplying failure or voltage drop below 80% of normal voltage, ATS will auto start Emergency generator set after a preset time of 0-10 sec (adjustable according to the users). Once generator reach at rated speed, the ATS will transfer the load to emergency generator sets automatically