Model Number: | D2FC-F-7N(10M) OF |
---|---|
Brand Name: | OMRON |
Place of Origin: | China (Mainland) |
Quick Details
Specifications
1, through the high precision, 2 pieces of the spring of the fast moving
mechanism to achieve long life.
2, the integral flux cannot climb forming terminal structure.
3, the printed substrate terminal also has an independent terminal,
right angle terminal. Welding terminals also have 2 shapes.
D2F-01 series 0.74N (low load) 1.47N (general type)
Allowable operation speed of needle type: 1mm ~ 500mm/s, swing rod type:
500mm/s ~ 5mm
Allowable operating frequency machine needle type button: 200 /min,
swing rod type: 100 times /min
Electrical 30 times /min
Insulation resistance 100M above (DC500V insulation resistance meter)
Contact resistance (initial value) 100m below 50m below 30m
High voltage terminal AC600V 50/60Hz 1min between the poles
Between 50/60Hz 1min AC1500V and
50/60Hz 1min AC1500V between the various terminals and the non electric
metal parts
Vibration * 10 mal operation frequency of 1 ~ 55Hz 1.5mm
Impact * 1 maximum durability 1000m/s2
Error maximum 300m/s2
Life * 2 (60 /min) 1000000 times.
Electrical 100000 or more (30 times /min) 30000 times (30 /min)
Protective structure IP40 IEC
The use of an ambient temperature of -25 to +85 DEG C below 60%RH (no
ice, no condensation)
The use of environmental humidity below 85%RH (+5 ~ +35)
Weight of about 0.5g (case)
mechanism to achieve long life.
2, the integral flux cannot climb forming terminal structure.
3, the printed substrate terminal also has an independent terminal,
right angle terminal. Welding terminals also have 2 shapes.
D2F-01 series 0.74N (low load) 1.47N (general type)
Allowable operation speed of needle type: 1mm ~ 500mm/s, swing rod type:
500mm/s ~ 5mm
Allowable operating frequency machine needle type button: 200 /min,
swing rod type: 100 times /min
Electrical 30 times /min
Insulation resistance 100M above (DC500V insulation resistance meter)
Contact resistance (initial value) 100m below 50m below 30m
High voltage terminal AC600V 50/60Hz 1min between the poles
Between 50/60Hz 1min AC1500V and
50/60Hz 1min AC1500V between the various terminals and the non electric
metal parts
Vibration * 10 mal operation frequency of 1 ~ 55Hz 1.5mm
Impact * 1 maximum durability 1000m/s2
Error maximum 300m/s2
Life * 2 (60 /min) 1000000 times.
Electrical 100000 or more (30 times /min) 30000 times (30 /min)
Protective structure IP40 IEC
The use of an ambient temperature of -25 to +85 DEG C below 60%RH (no
ice, no condensation)
The use of environmental humidity below 85%RH (+5 ~ +35)
Weight of about 0.5g (case)