Product Main

Quick Details

Coil Number: Autotransformer
Coil Structure: Toroidal
Phase: Single
Usage: Current
Model Number: KCT-16
Brand Name: HEYI
Place of Origin: China (Mainland)
Frequency: 50/60Hz
Window size: 16mm
Approval: CE Rohs
Accuracy: 0.5 1.0
Shell Color: Black

Specifications

The KCT range of split core current transformers have been specifically designed to be small and easy to open and yet maintain the accuracy required for kwh meters. The benefit of a split core current transformer is that it can be placed into position easily and without disturbing or disconnecting the main cables it is monitoring. The KCT range of current transformers has two insulated terminal covers for connecting the S1 and S2 cables which lock down over the terminal screws fully insulating the connections. This makes it ideal to use Autometers cable hamesses which are colour coded and individually numbered on each conductor ensuring simple and easy connection from the current transformer to the electricity meter.

 

Features:                                      

1The structure of the self-locking, safe, easy to install, portable             

2Wide inner window, allowing clamping of big cables or bus-bars 

3Wide range of sizes to accommodate all the existing installations

4Isolated plastic case recognized according to UL94-V0

UL / EN 61010 - 1

 

Applications:

1Current measurement, monitoring and protection for electrical wiring and equipment.

2Current and power measurement for electric motors, lighting, air

3compressor,heating and ventilation system, air-condition equipment and automation – control system.

4Current, power and energy monitoring device.

5Relay protection device.

Technique Index:

MODEL

KCT-16

Current Ratio

100A/33.3mA

100A/40mA

120A/40mA

200A/66.7mA

100~200A/0.333V

Primary Current(A)

100A

100A

120A

200A

100~200A

Max. Current(A)

120A

120A

120A

240A

/

Outpu

33.3mA

40mA

40mA

66.7mA

0.333V

Load Resistance(Ω)

50Ω

50Ω

50Ω

50Ω

/

Class

0.5/1.0

0.5/1.0

0.5/1.0

0.5/1.0

0.5/1.0

Turns Ratio

3000:1

2500:1

3000:1

3000:1

/

Protection Level

7.5V0-P

7.5V0-P

7.5V0-P

7.5V0-P

 

Insullation Category

CAT

Operating Condition

-20+50,≤85%RH,No condensation,IN-house&Any direction installable

Storage Condition

-30+50,≤85%RH,No condensation


Electrical Parameter

 

Mechanical Parameter

Frequency

50-2KHz 

Case

PA /UL94-V0

Rated Input

5A-630A

Bobbin

PBT

Measuring range

10%In-130%In

Core 

Silicon steel

Rated Output 

0.333V(AC) or 0-500mA

Internal structure

Epoxy

Ratio 

≤ ± 1.0%

Construction

Tie

Phase angle

≤ ±60min

Operating Temp

 -25oC~+75oC

Dielectric strength

2.5KV/1mA/1min

Operating Humidity 

≤85%

Insulation Resistance

DC500V/100MΩ min

Output Connection

UL 1015 20AWG Wire(twinsted wire) 2.5m