Coil Number: | Autotransformer |
---|---|
Coil Structure: | Toroidal |
Phase: | Single |
Usage: | Current |
Model Number: | KCT-16 |
Brand Name: | HEYI |
Place of Origin: | China (Mainland) |
Frequency: | 50/60Hz |
Window size: | 16mm |
Approval: | CE Rohs |
Accuracy: | 0.5 1.0 |
Shell Color: | Black |
Quick Details
Specifications
The KCT range of split core current transformers have been specifically designed to be small and easy to open and yet maintain the accuracy required for kwh meters. The benefit of a split core current transformer is that it can be placed into position easily and without disturbing or disconnecting the main cables it is monitoring. The KCT range of current transformers has two insulated terminal covers for connecting the S1 and S2 cables which lock down over the terminal screws fully insulating the connections. This makes it ideal to use Autometers cable hamesses which are colour coded and individually numbered on each conductor ensuring simple and easy connection from the current transformer to the electricity meter.
Features:
1) The structure of the self-locking, safe, easy to install, portable
2) Wide inner window, allowing clamping of big cables or bus-bars
3) Wide range of sizes to accommodate all the existing installations
4) Isolated plastic case recognized according to UL94-V0
UL / EN 61010 - 1
Applications:
1) Current measurement, monitoring and protection for electrical wiring and equipment.
2) Current and power measurement for electric motors, lighting, air
3) compressor,heating and ventilation system, air-condition equipment and automation – control system.
4) Current, power and energy monitoring device.
5) Relay protection device.
Technique Index:
MODEL |
KCT-16 |
||||
Current Ratio |
100A/33.3mA |
100A/40mA |
120A/40mA |
200A/66.7mA |
100~200A/0.333V |
Primary Current(A) |
100A |
100A |
120A |
200A |
100~200A |
Max. Current(A) |
120A |
120A |
120A |
240A |
/ |
Outpu |
33.3mA |
40mA |
40mA |
66.7mA |
0.333V |
Load Resistance(Ω) |
50Ω |
50Ω |
50Ω |
50Ω |
/ |
Class |
0.5/1.0 |
0.5/1.0 |
0.5/1.0 |
0.5/1.0 |
0.5/1.0 |
Turns Ratio |
3000:1 |
2500:1 |
3000:1 |
3000:1 |
/ |
Protection Level |
7.5V0-P |
7.5V0-P |
7.5V0-P |
7.5V0-P |
|
Insullation Category |
CATⅢ |
||||
Operating Condition |
-20℃~+50℃,≤85%RH,No condensation,IN-house&Any direction installable |
||||
Storage Condition |
-30℃~+50℃,≤85%RH,No condensation |
Electrical Parameter |
|
Mechanical Parameter |
||
Frequency |
50-2KHz |
Case |
PA /UL94-V0 |
|
Rated Input |
5A-630A |
Bobbin |
PBT |
|
Measuring range |
10%In-130%In |
Core |
Silicon steel |
|
Rated Output |
0.333V(AC) or 0-500mA |
Internal structure |
Epoxy |
|
Ratio |
≤ ± 1.0% |
Construction |
Tie |
|
Phase angle |
≤ ±60min |
Operating Temp |
-25oC~+75oC |
|
Dielectric strength |
2.5KV/1mA/1min |
Operating Humidity |
≤85% |
|
Insulation Resistance |
DC500V/100MΩ min |
Output Connection |
UL 1015 20AWG Wire(twinsted wire) 2.5m |