Brand Name: | GOOLE |
---|---|
Place of Origin: | China (Mainland) |
Port Size: | DN15-150 |
Media: | water,gas,steam,oil... |
Temperature of Media: | Medium Temperature |
Material: | copper,brass,bronze,strainless steel,cast,wcb... |
Power: | Manual |
Pressure: | Medium Pressure |
Structure: | Pressure Reducing |
Standard or Nonstandard: | Standard |
Quick Details
Specifications
Direct action Diaphragm type pressure reducing valve is a good choice for the branch pipe of the water supply system.
Product: Yz11x Direct action Diaphragm type branch pipe pressure reducing valve
Pressure Rating: 1.0- 1.6Mpa
Specification: DN15-50
Material: Brass, CF8
Standard screwed: NPT, BSP
Yz11x Structural characteristic and purpose
This series reducing valve is direct action membrane type spring reducing valve, it is manufactured and designed on the basis of advantages of foreign same products. It is mainly composed of membrane, valve flap, and adjusting spring. It sense the change of lower stream pressure through the membrane and drive the valve flap, change and control the valve opening to realize the function of pressure reducing the regulating. Set the outlet pressure by adjusting the spring pressure through adjusting bolt The product enlarges the area of membrane and improves the sensitivity. It is suitable for branch pipe of high buildings and apartment.
main technical parameters and indexes of performance
Product: Yz11x Direct action Diaphragm type branch pipe pressure reducing valve
Pressure Rating: 1.0- 1.6Mpa
Specification: DN15-50
Material: Brass, CF8
Standard screwed: NPT, BSP
Yz11x Structural characteristic and purpose
This series reducing valve is direct action membrane type spring reducing valve, it is manufactured and designed on the basis of advantages of foreign same products. It is mainly composed of membrane, valve flap, and adjusting spring. It sense the change of lower stream pressure through the membrane and drive the valve flap, change and control the valve opening to realize the function of pressure reducing the regulating. Set the outlet pressure by adjusting the spring pressure through adjusting bolt The product enlarges the area of membrane and improves the sensitivity. It is suitable for branch pipe of high buildings and apartment.
main technical parameters and indexes of performance
Nominal pressure
|
PN1.0Mpa
|
PN1.6Mpa
|
Tested pressure of shell
|
1.5Mpa
|
2.4Mpa
|
Sealing test pressure
|
1.0Mpa
|
1.6Mpa
|
Maximum upstream pressure
|
1.0Mpa
|
1.6Mpa
|
Pressure range of outlet
|
0.05-0.55Mpa
|
0.05-0.8Mpa
|
Minimum differential pressure
|
0.1Mpa
|
0.1Mpa
|
Medium
|
Water.
|
|
Operating temperature
|
0 -80
|