Features

Magnetic control, intermediate frequency, multi arc ion plating equipment are applied in hardware, glass crafts, ceramic crafts, etc., such as watches, mobile phones, metal shell, sanitary ware, cutting tools, moulds, electronic products, crystal glass and so on.

This series of equipment are mainly the technology integration of dc magnetron sputtering (set), intermediate frequency sputtering and arc ion , can adapt to the coating material,

No matter metal , medium or compound material, can take advantage of the sputtering process for coating and film forming, and improve the film adhesion, density, complex degree and color consistency. It can plate TiN and TiC, TiCN and TiAlN, CrN, CU, AU, diamond film (DLC), decorative film and nonmetal and its compound membrane and composite membrane layer. Programmable controller (PLC) + touch screen (HMI) combined electrical control system, fully automatic control.

Technical parameters

Film type

Black gold titanium nitride, titanium carbide, 7 colour titanium oxide and wear-resistant film, super hard film, diamond film, metal decorative film, etc

The power supply type

Dc power supply, intermediate frequency power supply, arc power supply, filament,  pulse bias power supply

Mutli-arc target

Mutli-arc target5 or 18,

The twin target

Intermediate frequency twin column target or target plane (1-4cuples)

Vacuum chamber structure

Vertical before the door structure (double or sink type cooling water jacket type), rear extraction system

Vacuum system

Rotary vane pump, roots pump and diffusion pump + maintain pump (or optional: molecular pump, cryogenic pump, cryogenic system)

Heating system

From room temperature to 350 degrees adjustable control (PID temperature control), stainless steel heating tube heating

Pneumatic system

Mass flow controller (1-4line)

Ultimate vacuum

6×104 pa(Light, clean room)

Extraction time

5×103 pa<13minutes

The rate of keeping air pressure

1h≤0.6pa

Work piece rotating way

Common rotation frequency conversion stepless control is adjustable, 0 to 20 RPM

The control mode

Manual, semi-automatic and fully automatic integration/touch screen + PLC

note

Vacuum chamber size can be customized according to the requirements of customers products and special process