Product Main

Quick Details

Brand Name: JZD
Place of Origin: China (Mainland)

Specifications

Product function characteristics:

(1)Adopts full copper toroidal transformer, Low self-consumption, No-load current less than 0.6A.

(2)The inverter is designed by our company independently; it's controlled by CPU, high quality and modify sine wave intelligent inverter 

(3)Our product is used for the many kinds of the single phase equipments, example: motor, screw tools,tube light etc.family equipments, and also it can be used for the industry and communication equipments.

(4)Single key intelligent switching, easy to operated.

(5)Output short circuit protection (when the inverter is working on battery mode): when there is short circuit, the inverter will indicate it and the machine will shut down automatically.

(6)Overload protection is designed to improve the effective protection of the safe operation of the inverter when the load capacity over 100% to 120% of the inverter is working properly, when the load is over 150%,the inverter will turn off in 10 seconds.

(7)Internal circuit can protect the battery .when the battery voltage is under the 15% level,the inverter will be shut down at once.

 

Specification:

Model

350W

500W

700W

1KW

1.5KW

2KW

3KW

4KW

5KW

AC input

 Input voltage

120-275VAC

145-275VAC

 Input frequency

50HZ/60HZ±5%

Charging current

15A(Max)

Inverter specification

Rated capacity

350W

500W

700W

1KW

1.5KW

2KW

3KW

4KW

5KW

DC voltage

12V/24V

24V/48VDC

48VDC

48V/96VDC

Battery input voltage range

DC12V(DC10.5V-DC15V)/ DC24V(DC21V-DC30V)/

 DC48V(DC42V-DC60V)/DC96V(DC84V-DC120V)

Output voltage

220VAC±10%

Frequency

50HZ/60HZ

Output waveform

Pure sine wave

Efficiency

≥85%(load100%)

No-load current

≦0.6A

Total harmonic distortion

Linear load<3% nonlinear load<5%

Over load ability

100-120% alarm;   120-150%, 10s turn off

Protection

 input over votlage/under voltage protection, DC undervoltage / overvoltage protection, peak surge protection, overload, short circuit protection

switch time between the batteries and City power

≦4MS

LCD display

Inverter input ovltage,input frequency,output voltage,output frequency,battery capacity percentage

Operating temperature

0-40℃

Storage  temperature

-15 - +50℃

Relative humidity

20-93% no condensation

Altitude level

Altitude is less than 1000m(Each additional 100m  power fell by 1%, the highest is  4000m)

Unit size: D×W×H(mm)

330*220*120

390*150*210

400*190*300

420*200*350

382*255*450

Packing size: D×W×H(mm)

400*280*190

470*200*280

480*240*380

560*320*430

628*375*710

N/G weight(KG)

6.6/7.5

6.5/8

8.5/10

10.5/12

14.8/16

15.8/17

20/26.5

35/45

37.5/47

Note: according to user's actual situation would chose mains or battery priority.










































All Categories