| Model Number: | ET310B |
|---|---|
| Brand Name: | E-one |
| Place of Origin: | China (Mainland) |
Quick Details
Specifications
Specification:
|
Analog bandwidth |
DC ~ 20MHz |
||
|
Max. sampling rate |
100Msps |
Vertical resolution |
8 bits |
|
Channel |
1 |
couple |
DC/AC/GND |
|
Input impedance |
10MΩ |
Div |
vertical ±4.8 div horizontal 12.8 div |
|
Vertical sensitivity range |
50mV/div ~ 200V/div |
Time base |
0.20μs/div ~ 20s/div |
|
Vertical amplitude accuracy |
±(5%+ 0.1div) |
Time base accuracy |
±(0.01% + 0.1div) |
|
Auto-Zero calibrating |
In DC/dB measurement |
Measuring mode |
Auto/normal/single |
|
Trigger level |
± 12 div (every step interval 0.1div) |
slop of selection |
Rising edge/ Falling edge |
|
Trigger condition |
± 6div (every step interval 0.1div) |
Auto setting |
Auto setting time base and amplitude |
|
Cursor measuring |
dV, dt, 1/dt |
Auto measuring |
Vp-p, Vavg, RMS, dBm |
|
Auto measuring accuracy |
±(5%+ 0.1div) |
Recording length |
12.8div |
Measuring Range and Accuracy:
|
fFunction |
Range |
Resolution |
Accuracy |
|
DC Voltage |
400.0mV |
0.1mV |
±(0.75%rdg + 10dgt) |
|
4.000V |
1mV |
||
|
40.00V |
10mV |
||
|
400.0V |
100mV |
||
|
1000V |
1V |
±(1.5%rdg + 10dgt) |
|
|
AC Voltage
|
400.0mV |
0.1mV |
50Hz~400Hz
±(1.0%rdg + 10dgt) ±(2.0%rdg + 10dgt) |
|
4.000V |
1mV |
||
|
40.00V |
10mV |
||
|
400.0V |
100mV |
||
|
750V |
1V |
±(1.5%rdg + 10dgt)(50Hz~400Hz) |
|
|
DC Current |
40.00/400.0mA |
10μA /100μA |
±(1.2%rdg + 10dgt) |
|
4.000/20.00A |
1mA /10mA |
||
|
AC Current |
40.00/400.0mA |
10μA /100μA |
±(1.5%rdg + 10dgt) |
|
4.000/20.00A |
1mA /10mA |
||
|
Resistance |
400.0W |
0.1 Ω |
±(1.0%rdg + 5dgt) |
|
4.000kW |
1 Ω |
||
|
40.00kW |
10 Ω |
||
|
400.0kW |
100 Ω |
||
|
4.000MW |
1kW |
||
|
40.00MW |
10kW |
±(3.0%rdg + 5dgt) |
|
|
Capacitance |
51.20nF |
1pF |
±(2%rdg + 10dgt) |
|
512.0nF |
10pF |
±(1%rdg + 3dgt) |
|
|
5.120μF |
100pF |
±(1%rdg + 3dgt) |
|
|
51.20μF |
1nF |
±(1.5%rdg + 3dgt) |
|
|
100.0μF |
10nF |
±(5%rdg + 3dgt) |
|
|
Frequency |
5.12Hz ~ 10kHz |
0.1Hz ~ 10Hz |
±(1.0%rdg + 5dgt), (signal width no less than 1Vp-p,AC V or 20mA RMS, AC A) |
|
Duty cycle |
0.1~99.9% (AC 1Vp-p) |
||
|
Diode test |
Open-circuit voltage is about 1.5 V, Max. measuring current is about 1.5mA |
||
|
Continuity |
About 30Ω |
||
|
Auto range switch |
Adoptable in each measuring range |
||
|
Measuring range over load indicate |
" O. L" (Over load) |
||
|
DMM measuring rate |
2.5 t/s |
||
|
Dynamic data window |
Dynamic refresh actual measuring data after main display data hold |
||
|
dB (-80~+80dB)reference impedance |
2, 3, 8, 16, 50, 75, 93, 110, 125, 135, 150, 300, 600, 900, 1000, 1200 Ω |
||
|
Fuse specification |
Φ5×20, 0.5A/250V Φ10×38, 20A/500V |
||