| Dimensions: | 186mm*80mm*32mm |
|---|---|
| Operating Temperature: | Nromal |
| Measuring Inductance Range: | -- |
| Measuring Capacitance Range: | 51.20nF/521.0nF/5.120*F/51.20*F/100*F |
| Measuring Resistance Range: | 400ohms/4Kohms/40Kohms/400K/400Kohms/4Mohms/40Mohms/4Mohms/40Mohms |
| Measuring Voltage Range: | 400mV/4V/40V/400V/600V |
| Measuring Current Range: | 40mA/400mA/4A/20A |
| Model Number: | VC105 |
| Brand Name: | E-One |
| Place of Origin: | China (Mainland) |
Quick Details
Specifications
Features:
VC105 Absolutely waterproof ! The sealed design extending the using expectancy of the meter and enables it working under bad weather and environment. And more vagariously, it equipped with the Inner rechargeable battery, so that no battery replacement needed, convenient and environment friendly.
- 3 3/4 digits display and Auto-rang
- REL mode, effectively eliminate lead-wire resistance or interference signals.
- Auto power-off when the instrument idle for 15 min.
- White backlight and convenient for dim light condition usage.
- Manual/Auto measuring range exchange.
- Rechargeable battey built-in and outsite AC power supply adapter
- Extended RS232 interface
Specification:
|
Function |
Range |
Resolution |
Accuracy |
|
DC Voltage |
400.0mV |
0.1mV |
± (0.8%rdg + 10dgt) |
|
4.000V |
1mV |
||
|
40.00V |
10mV |
||
|
400.0V |
100mV |
||
|
600V |
1V |
± (1.5%rdg + 10dgt) |
|
|
AC Voltage Average RMS |
400.0mV |
0.1mV |
AC mV (only manually switch measuring range) 50Hz~400Hz ± (1.2%rdg + 10dgt) |
|
4.000V |
1mV |
||
|
40.00V |
10mV |
||
|
400.0V |
100mV |
||
|
600V |
1V |
± (1.5%rdg + 10dgt)(50Hz~400Hz) |
|
|
DC Current |
40.00/400.0mA |
10μA /100μA |
± (1.2%rdg + 10dgt) |
|
4.000/20.00A |
1mA /10mA |
||
|
AC Current |
40.00/400.0mA |
10μA /100μA |
50Hz~400Hz ± (1.5%rdg + 10dgt) |
|
4.000/20.00A |
1mA /10mA |
||
|
Resistance |
400.0Ω |
0.1Ω |
± (1.0%rdg + 5dgt) |
|
4.000kΩ |
1Ω |
||
|
40.00kΩ |
10Ω |
||
|
400.0kΩ |
100Ω |
||
|
4.000MΩ |
1kΩ |
||
|
40.00MΩ |
10kΩ |
± (3.0%rdg + 5dgt) |
|
|
Capacitance |
51.20nF |
1pF |
± (2%rdg + 10dgt) |
|
512.0nF |
10pF |
||
|
5.120μF |
100pF |
||
|
51.20μF |
1nF |
||
|
100.0μF |
10nF |
± (5%rdg + 3dgt) |
|
|
Frequency |
5.12Hz ~ 5.12MHz |
0.1Hz ~ 10Hz |
± (1.0%rdg + 5dgt),(signal width no less than 1Vp-p, AC V or 20mA RMS, ACA) |
|
Duty cycle |
0.1~99.9% (AC 1Vp-p) |
||
|
Diode test |
Open-circuit voltage is about 1.5V, Max. measuring current is about 0.5 mA |
||
|
Continuity test |
About 30Ω |
||
|
Auto-range exchange |
Adoptable in each measuring range |
||
|
Measuring range over load indicate |
" O. L" (Over load) |
||
|
Measuring rate |
2.5 t/s |
||
|
Fuse specification |
Φ5×20,500mA/250V Φ10×38,20A/500V |
||