We provide external fire fighting systems(fifi class I/II/II systems)for all kinds of vessels,oil platforms,etc with CCS,BV,ABS,DNV and other class certificates.
Details
1. Fifi class 2 system,7200m3/h
Diesel engine driven
Fire pumps:2X3600m3/h
Fire monitors:4X1800m3/h@150m or 3x2400m3/h
Remote control system
2. Fifi class 1 system,2400m3/h
Diesel engine driven
Fire pumps:2X1200m3/h or one 2400m3/h
Fire monitors:2X1200m3/h@120m
Remote control system
3. Fifi 1/2 system,1200m3/h
Diesel engine driven
Fire pumps:1200m3/h
Fire monitors:2X600m3/h@120m or 1X1200m3/h@120m
Remote control system
4. None classed fi-fi system
Diesel engine driven
Or electric motor driven
Fire pumps:2X300m3/h@145m
Fire monitors:2X300m3/h@85m
Remote control system
Fire pumps:300m3/h@145m
Fire monitors:300m3/h@85m
Remote control system
Fire pumps:250m3/h@110m
Fire monitors:250m3/h@70m
Remote control system
Fi-Fi I,Fi-Fi II And Fi-Fi III
Class Notation |
Fifi1 |
Fifi2 |
Fifi3 |
||||
No.of Monitors |
2 |
2 |
3 |
4 |
3 |
4 |
|
Monitor Capacity (m3/h) |
1200 |
3600 |
2400 |
1800 |
3200 |
2400/2500 |
|
No.of Pumps |
1-2 |
2 |
2-4 |
2 |
2-4 |
||
Total Pump Capacity (m3/h) |
2400 |
7200 |
7200 |
9600 |
9600/10000 |
||
Throw Length (m) |
120 |
180 |
150 |
180 |
150 |
||
Throw height(m) |
45 |
110 at 70m |
70 |
110 at 70m |
70 |
Components
Fire monitor
Fire pump
Diesel engine
External FIFI system