Model Number: | XKSGKL |
---|---|
Brand Name: | HSLEC |
Place of Origin: | China (Mainland) |
Rated voltage: | 6kv/10kv |
Rated Current: | 100-5000A |
Installation Method: | Horizontal or Vertical |
Cooling type: | AN AF |
Working Site: | Indoor / Outdoor |
Standard: | GB/T 1094.6 |
Insulation class: | F |
Certificate: | ISO&CE |
Quick Details
Specifications
10KV three phase dry type air core current limiting reactors
Quick Information:
a. The dry type air core current limiting reactor is applicable to 6-35kv power transmission and transformation system.The reactance value is not affected by current changes.
b. It funcations to limit high harmonics,switching inrush current and operate over-voltage and also change the voltage addition to improving power supply quality,it can restrain short-circuit current to ensure reliable performance of electrical equipment.
Service conditions:
a. Service site: indoor or outdoor
b. Ambient temp.:-30~60 degree( or according to customer's requirment)
c. Altitude: <=10000m( if it exceeding to 1000m, pls declare in order).
d. Max. Wind speed: 35m/s
e. Relative humidity: <=90%
f. Earthquake resistant capability: horizontal direction 0.3g verticle direction0.15g (or by customer's requirments)
Features:
a. Our current limiting reactor can extend equipment lifecycle and reduce electrical losses.
b. It has high mechanical strength to withstand elevated short circuit.
c. Conservative temperature rise.
d. Maintenance-free design.
e. Environmentally friendly.
There are XKSGKL and XKSGK series of our air core current limiting reactor. Each series includes many models with different parameters to suit diversified customer needs.
For example, the XKSGKL-6-200-3 air core current limiting reactor has its rated voltage of 6KV, rated current of 200AV, and reactance ratio of 3%.
As to XKSGK-6-200-8 air core current limiting reactor, it comes with 6KV rated voltage, 200AV rated current, and reactance ratio of 8%. For more information about parameters of the two series, please refer to corresponding data table as follows.
B
The basic order data
6.1, Rated voltage(kV)
6.2, Rated reactance rate(%)
6.3, Rated current(A)
6.4, Rated reactance(Ω)
6.5, Rated capacity(kVar)
6.6, Installation way
6.7, Indoor or outdoor
6.8, Angle of inlet-outlet line terminal
6.9 , Cooling type
6.10, Any other Special requirements
1. XKSGKL Series Dry-type Air Core Current Limiting Reactor
Technical Parameters
Model | Rated Voltage KV | Rated Current AV | Reactance Ratio % | Dynamic Current KA | Short Time Current 4S KA | Rated Inductance mH |
Single Phase Capacity kvar |
Single Phase Loss kW |
Coil External Diameter mm | Coil Height | Down Porcelain Height mm | Porcelain Center Diameter mm | Point | Single Phase Weight kg |
XKSGKL-6-200-3 | 6 | 200 | 3 | 12.8 | 5 | 1.65 | 20.8 | 1.25 | 990 | 490 | 515 | 820 | 3 | 115 |
XKSGKL-6-200-4 | 4 | 2.21 | 27.7 | 1.5 | 1045 | 520 | 515 | 880 | 3 | 132 | ||||
XKSGKL-6-200-5 | 5 | 2.76 | 34.6 | 1.75 | 1040 | 570 | 515 | 880 | 3 | 148 | ||||
XKSGKL-6-200-6 | 6 | 3.31 | 41.6 | 2.01 | 1090 | 600 | 515 | 910 | 3 | 168 | ||||
XKSGKL-6-200-8 | 8 | 4.41 | 55.4 | 2.41 | 1090 | 660 | 515 | 910 | 3 | 191 | ||||
XKSGKL-6-200-10 | 10 | 5.51 | 69.3 | 2.8 | 1190 | 750 | 580 | 1000 | 3 | 212 | ||||
XKSGKL-10-200-3 | 10 | 3 | 2.76 | 34.6 | 1.75 | 1095 | 590 | 515 | 910 | 3 | 148 | |||
XKSGKL-10-200-4 | 4 | 3.68 | 46.2 | 2.15 | 1095 | 610 | 515 | 910 | 3 | 173 | ||||
XKSGKL-10-200-5 | 5 | 4.59 | 57.7 | 2.51 | 1090 | 720 | 515 | 910 | 3 | 196 | ||||
XKSGKL-10-200-6 | 6 | 5.51 | 69.3 | 2.73 | 1195 | 730 | 580 | 1000 | 3 | 217 | ||||
XKSGKL-10-200-8 | 8 | 7.35 | 92.4 | 3.33 | 1290 | 840 | 680 | 1100 | 3 | 259 | ||||
XKSGKL-10-200-10 | 10 | 9.19 | 115.5 | 3.95 | 1340 | 890 | 680 | 1150 | 3 | 295 | ||||
XKSGKL-6-300-3 | 6 | 300 | 3 | 19.1 | 7.5 | 1.1 | 31.2 | 1.83 | 990 | 500 | 515 | 820 | 3 | 115 |
XKSGKL-6-300-4 | 4 | 1.47 | 41.6 | 2.2 | 1045 | 530 | 515 | 880 | 3 | 133 | ||||
XKSGKL-6-300-5 | 5 | 1.84 | 52 | 2.32 | 1040 | 580 | 515 | 880 | 3 | 164 | ||||
XKSGKL-6-300-6 | 6 | 2.21 | 62.4 | 2.59 | 1095 | 620 | 515 | 910 | 3 | 180 | ||||
XKSGKL-6-300-8 | 8 | 2.94 | 83.1 | 3.16 | 1145 | 680 | 580 | 980 | 3 | 212 | ||||
XKSGKL-6-300-10 | 10 | 3.68 | 103.9 | 3.57 | 1190 | 760 | 580 | 1000 | 3 | 242 | ||||
XKSGKL-10-300-3 | 10 | 3 | 1.84 | 52 | 2.49 | 1040 | 600 | 515 | 880 | 3 | 148 | |||
XKSGKL-10-300-4 | 4 | 2.45 | 69.3 | 2.76 | 1140 | 620 | 580 | 980 | 3 | 192 | ||||
XKSGKL-10-300-5 | 5 | 3.06 | 86.6 | 3.17 | 1145 | 690 | 580 | 980 | 3 | 217 | ||||
XKSGKL-10-300-6 | 6 | 3.68 | 103.9 | 3.62 | 1190 | 740 | 680 | 1000 | 3 | 241 |
Rated Current: 100~5000A
Rated Voltage: 6KV/10KV
Rated reactance rate:3-12%
Installation Method: Horizontal or Vertical
Product Executive Standard: GB/T1094.6
Notes:The above technical parameters are just for your reference and we can do as customzied.
More Dry Type Air Core Reactors for your choose
Dry-type Aire Core Smoothing Reactor
Dry-type Air Core Series Reactors
Dry-type Air Core Current Limiting Reactors
Dry-type Air Core Shunt Reactors
Dry-type Air Core Starting Reactors
Dry-type Filter Reactors
Packing:Security Export Wooden Cartons
Shipping:4-30 days,by air or by sea as the customized
HSLEC PROFILE
1.Founded in 1992,Huashenglong Electrical Equipment Co.,Ltd.(HSLEC)is a mamufactuer of dry type transformer and dry type reactor,located in Qinhuangdao,a beautiful coastal city of China.
2.We are able to research,develop,and produce many types of dry type transformer and dry type reactor,high and low voltage transformers ,air core reactor,line reactor and so on.
More Transformers and Reactors:
S9 S11 S13 Oil type transformer:50-31500KVA,6-33KV,50/60HZ,off load tape changer
SZ9 SZ11 oil type transformer:50-31500KVA, 6-33KV,50/60HZ, On load tape changer
SCB9,SCB11 dry type transformer: F grade insulation, 50-3150KVA,6-33KV, 50/60HZ
SCBH15 11KV amorphous alloy dry type transformer:F grade insulation
SGB10 SGB11 11KV dry type transformer:H grade insulation
SBH15 Oil type amorphous alloy transformer 11KV Level
Dry type reactor
SC(G)Dry-type shunt reactor
SC Dry Startup reactor
Smoothing reactors
low-pressure filter reactor
Cast resin dry type earthing transformer
Dry type rectifier transformer
Rectifier transformer
Furnace transformer
CE&ISO CERTIFICATIONS:
International Market
1.During the past 18 years, we have continued to upgrade and improve our equipment and our quality control system.
2.Now,HSLEC is a top ranked manufature in China's electrical equipment industry, and our power transformer,
current-limiting reactor,etc.,are exporeted to America,India,Thailand,Turkey,Georgia,and Sigapore,among others.
1. Pre-Sale Service
- Professional question: offer professional answers about transformers and reactors
- Quotation: quote you competive price of transformers and reactors
- Quick response: reply you within 24 hours
2. In Sale Service
- Tracking the production of the transformers and reactors, then feed back to you
- Making transformer and reactor arrangement of the delivery
3. After Sale Service
- Providing 12 months warranty for the quality and performance
1.Q: Are you manufacturer or trading company?
A: Manufacturer
2.Q: What is your minimum order quantity?
A: 1 set.
3.Q: What is your delivery time ?
A: Depend on the type of transformer.
4.Q: What is your payment term?
A: 30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it.
5.Q: What kind of starndard you follow?
A: IEC, ANSI, CSA, GB, etc
6. Q: What kind of supporting documentation you can provide normally
A: Quotation,outline drawing,manufacturing plan, quality control plan,testing plan, financial report, type test report(KEMA, CESI),reference list,etc
7. Q:What is your normal wanrranty period?
A: 12 months after goods shipped.
8. Q: Can u do installation and commissioningin user's site?
A: Yes, we can send our installation team to user's country for service.
9. Q: Do you have any experience in this kind of product?
A: Yes, we can provide reference list for check.