Model Number: | LKGK(L)T |
---|---|
Brand Name: | HSLEC |
Place of Origin: | China (Mainland) |
rated voltage: | 6kv 10kv 20kv 35kv as customized |
Rated Capacity: | 5.9-1725kvar |
Installation Method: | Horizontal or vertical |
Insulation class: | F |
Working Site: | Indoor / Outdoor |
Certificate: | ISO&CE |
Quick Details
Specifications
10KV 32KVAR high voltage air core harmonic filter reactor
Brief Introduction:
The filter inductor is used in series connection with filter capacitor bank to form resonant circuit for filtering specified higher harmonic currents.
Basic Order Data
1.Rated Voltage:6~35KV
2.Rated Current:100-622A
3.Installation Method: Horizontal or Vertical
4.Operation Site: indoor or outdoor
5. Angle of incoming or outcoming terminals
Service conditions
1. Service site: indoor or outdoor
2. Ambient temp.:-30~60 degree( or according to customer's requirment)
3. Altitude: <=10000m( if it exceeding to 1000m, pls declare in order).
4. Max. Wind speed: 35m/s
5. Relative humidity: <=90%
6. Earthquake resistant capability: horizontal direction 0.3g verticle direction0.15g (or by customer's requirments)
More Details:
Specification
Huashenglong have LKGKLT and LKGKT series of filter reactor, including a variety of models.
for example. The LKGKLT-6-365-1.85 filter inductor is designed with system voltage of 6kv, rated current of 365A, rated inductance of 1.85mH, and rated capacity of 77kvar.
For the LKGKT-6-500-0.23 filter reactor, it has system voltage of 6kv, with its rated current of 500A, rated inductance of 0.23mH, and rated capacity of 18 kvar. If you want to know more specific information about the dry type air core filter choke, please refer to the following data table.
The basic order data
1.Rated frequency 2.Rated voltage 3.Rated current 4.Rated inductance 5.Inductance adjust range 6.Rated quality factor 7.Rated short time current and duration 8.Rated tuning frequency 9. Rated tuning frequency current 10.Insulation level 11. Install method and Incoming and outgoing line angle 12. Working site(indoor or outdoor)
1. LKGKLT Series Dry-type Air Core Filter Reactor
Technical Parameters
No. | Rated Capacity | Model | System Voltage | Rated Current | Rated Inductance | Inductance Range | External Diameter | Height | Total Height | Assembly Height | Point | Single Phase Weight |
kvar | kV | A | mH | % | mm | mm | mm | mm | kg | |||
1 | 18 | LKGKLT-6-500-0.23 | 6 | 500 | 0.23 | ±5 | 1510 | 430 | 2150 | 1320 | 3 | 516 |
2 | 33 | LKGKLT-6-238-1.86 | 238 | 1.86 | ±5 | 1500 | 530 | 2255 | 1320 | 3 | 559 | |
3 | 55 | LKGKLT-6-300-1.95 | 300 | 1.95 | ±5 | 1570 | 575 | 2580 | 1380 | 4 | 752 | |
4 | 77 | LKGKLT-6-365-1.85 | 365 | 1.85 | ±5 | 1600 | 540 | 2430 | 1380 | 4 | 652 | |
5 | 125 | LKGKLT-6-400-2.48 | 400 | 2.48 | ±5 | 1710 | 585 | 2600 | 1550 | 4 | 894 | |
6 | 12 | LKGKLT-6.3-140-1.88 | 6.3 | 140 | 1.88 | ±5 | 1490 | 535 | 2395 | 1320 | 3 | 527 |
7 | 18 | LKGKLT-6.3-410-0.35 | 410 | 0.35 | ±5 | 1310 | 485 | 2180 | 1150 | 3 | 551 | |
8 | 27 | LKGKLT-6.3-405-0.52 | 405 | 0.52 | ±5 | 1360 | 540 | 2280 | 1150 | 4 | 631 | |
9 | 37 | LKGKLT-6.3-220-2.46 | 220 | 2.46 | ±5 | 1550 | 610 | 2565 | 1320 | 4 | 733 | |
10 | 5.9 | LKGKLT-10-102-1.82 | 10 | 102 | 1.82 | ±5 | 1160 | 470 | 2160 | 980 | 3 | 275 |
11 | 16 | LKGKLT-10-108-4.46 | 108 | 4.46 | ±5 | 1070 | 445 | 2045 | 920 | 3 | 278 | |
12 | 32 | LKGKLT-10-108-8.73 | 108 | 8.73 | ±5 | 1120 | 550 | 2320 | 950 | 3 | 342 | |
13 | 1642 | LKGKLT-12-622-13.52 | 12 | 622 | 13.52 | ±5 | 1750 | 700 | 2588 | 1580 | 4 | 1881 |
14 | 135 | LKGKLT-18.2-145-20.45 | 18.2 | 145 | 20.45 | ±5 | 1480 | 590 | 1950 | 1300 | 4 | 628 |
15 | 175 | LKGKLT-18.2-345-4.68 | 18.2 | 345 | 4.68 | ±5 | 1370 | 425 | 2125 | 1180 | 3 | 601 |
16 | 542 | LKGKLT-18.2-316-17.28 | 316 | 17.28 | ±5 | 1680 | 600 | 2615 | 1520 | 4 | 1059 | |
17 | 1725 | LKGKLT-18.2-414-32.06 | 414 | 32.06 | ±5 | 1790 | 785 | 2045 | 1580 | 4 | 1693 | |
18 | 100 | LKGKLT-35-102-30.62 | 35 | 102 | 30.62 | ±5 | 1390 | 490 | 2115 | 1220 | 3 | 542 |
19 | 156 | LKGKLT-35-102-47.81 | 102 | 47.81 | ±5 | 1490 | 580 | 2195 | 1320 | 4 | 625 | |
20 | 310 | LKGKLT-35-105-89.42 | 105 | 89.42 | ±5 | 1750 | 810 | 2505 | 1580 | 4 | 853 | |
21 | 350 | LKGKLT-35-105-101.0 | 105 | 101.06 | ±5 | 1970 | 630 | 2895 | 1800 | 4 | 1046 | |
22 | 914 | LKGKLT-35-100-291.12 | 100 | 291.12 | ±5 | 2060 | 845 | 3445 | 1850 | 4 | 1784 | |
23 | 1333 | LKGKLT-35-155-176.71 | 155 | 176.71 | ±5 | 2260 | 875 | 4275 | 2100 | 4 | 1995 |
Features:
1. Our filter reactor provides decreased electrical losses and extended service life of equipment.
2. This high voltage reactor is able to eliminate interference with other equipment
3. The filter inductor boasts surface protection from UV radiation and pollution.
4. Low Q-factor, maintenance-free design
5. Environmentally friendly
6. Conservative temperature rise
7. High mechanical strength
8. Tapping adjustable
9. Customized space-saving solutions for installations of filter reactor in compact areas are available at Huashenglong.
Packing:Security Export Wooden Cartons
Shipping:4-30 days,by air or by sea as the customized
1.Established in 1992, Huashenglong Electrical Equipment Company is an ISO9001:2008
certified manufacturer in China.
2.HSLEC offer a wide variety High Voltage and Low Voltage power products including power transformers, distribution transformers,air core reactors, iron core reactors and line reactors
and output reactors compatible to variety frequecny inverters and governors.
3.We have one machining workshop, two wire winding workshops, complete special-use and
universal-use equipment, a complete set of inspection equipment, and large-scale winding
equipment.
4.With reliable quality and low prices, our dry type reactor and power transformer are sold well
in America, Turkey, India, Thailand, Saudi Arabia, Vietnam, Georgia, etc.
addition, we also can fulfill your OEM requests.
More Product :
S9 S11 S13 Oil type transformer:50-31500KVA,6-33KV,50/60HZ,off load tape changer
SZ9 SZ11 oil type transformer:50-31500KVA, 6-33KV,50/60HZ, On load tape changer
SCB9,SCB11 dry type transformer: F grade insulation, 50-3150KVA,6-33KV, 50/60HZ
SCBH15 11KV amorphous alloy dry type transformer:F grade insulation
SGB10 SGB11 11KV dry type transformer:H grade insulation
SBH15 Oil type amorphous alloy transformer 11KV Level
Dry type reactor
SC(G)Dry-type shunt reactor
SC Dry Startup reactor
Smoothing reactors
low-pressure filter reactor
Cast resin dry type earthing transformer
Dry type rectifier transformer
Rectifier transformer
Furnace transformer
1. Pre-Sale Service
- Professional question: offer professional answers about transformers and reactors
- Quotation: quote you competive price of transformers and reactors
- Quick response: reply you within 24 hours
2. In Sale Service
- Tracking the production of the transformers and reactors, then feed back to you
- Making transformer and reactor arrangement of the delivery
3. After Sale Service
- Providing 12 months warranty for the quality and performance
1.Q: Are you manufacturer or trading company?
A: Manufacturer
2.Q: What is your minimum order quantity?
A: 1 set.
3.Q: What is your delivery time ?
A: Depend on the type of product.
4.Q: What is your payment term?
A: 30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it.
5.Q: What kind of starndard you follow?
A: IEC, GB, etc
6. Q: What kind of supporting documentation you can provide normally
A: Quotation,outline drawing,manufacturing plan, quality control plan,testing plan, financial report, type test report,reference list,etc
7. Q:What is your normal wanrranty period?
A: 12 months after goods shipped.
8. Q: Can u do installation and commissioningin user's site?
A: Yes, we can send our installation team to user's country for service.
9. Q: Do you have any experience in this kind of product?
A: Yes, we can provide reference list for check.