| Model Number: | SF100100 |
|---|---|
| Brand Name: | OUGOOD |
| Place of Origin: | China (Mainland) |
| Product Name: | X Ray Security Scanner With Tunner Size Of 1000 *1000mm |
| Tunnel Size: | (W)*1000(H)mm |
| Equipment Size: | 3460(L)*1280(W)*1870(H) Mm |
| Conveyor Speed: | 0.22m/s |
| Conveyor Max Load: | 230 Kg |
| Film Safety: | For ISO 1600 |
| Warranty: | 1 Year |
Quick Details
Specifications
Railway High Precision X Ray Baggage Scanner with Conveyor Speed of 0.22m / s
TECHNICAL DATA:
* Especially designed for high way, railway, port, customs, bus station and other publics
* Strict quality control, double test in engineering and producing
* Spare parts guaranteed
* High performance network
* Test Report from Inspection Center of State Security Ministry
* CE certificate
* ISO9001 certificate-German TUV
* ISO14001 certificate
* Radiation safety certificate from Chinese Government
With Threat Image Projection (TIP): which can record the dangerous items' information ,and when detect the dangerous item, it will have the voice alarm.
Tunnel Size: 1000(W)×1000(H)mm
Equipment size: 3460(L)*1280(W)*1870(H) mm
Conveyor Speed: 0.22m/s
Conveyor Max Load: 230 kg
Single inspection dosage < 1.5μGy
Wire Resolution: 0.101mm metal line
Steel Penetration: 34MM armor plate
Film Safety: For ISO 1600
Maximum leakage radiation :<0.1μGY/H
X-RAY GENERATOR:
Orientation: Vertically Upward
Tube Current: 0.4~1.2MA(adjustable)
Anode Voltage: 100~160 kV (adjustable)
Angle: 60°
Generator cooling/working periods: Sealed oil bath with forced air/100%
OPERATING ENVIRONMENT:
Storage Temperature: -20oC to 60oC
Operating Temperature: 0oC to 45oC
Relative Humidity: 20 to 95% non-condensing
System Power: 220 VAC (±10%) 50±3HZ
Power wastage: 1.0 KW (Max)
Noise: <64DB
Weight:1200KG
|
Tunnel size: |
1000(W)×1000(H)mm |
|
Equipment size: |
3460(L)*1280(W)*1870(H) mm |
|
Conveyor speed: |
0.22 m/s |
|
Conveyor maximum load: |
230 kg |
|
Single inspection dosage |
<1.5μgy |
|
Wire resolution |
0.101mm metal line |
|
Steel penetration: |
34MM armor plate |
|
Film safety: |
for ISO 1600 |
|
Maximum leakage radiation |
<0.1μGY/H |
|
Weight: |
1200KG |
|
Orientation: |
Vertically Upward |
|
Tube Current: |
0.4~1.2MA(adjustable) |
|
Anode Voltage: |
100~160 kV (adjustable) |
|
Angle: |
60° |
|
Generator cooling/working periods Sealed oil bath with forced air/100% |
|
|
Storage Temperature: |
-20oC to 60oC |
|
Operating Temperature: |
0oC to 45oC |
|
Relative Humidity: |
20 to 95% non-condensing |
|
System Power: |
220 VAC (±10%) 50±3HZ |
|
Power wastage |
1.0 KW (Max) |
|
Noise: |
<64DB |