| Application: | Computer |
|---|---|
| Type: | On-line |
| Protection: | Overcurrent |
| Phase: | Three Phase |
| Model Number: | View Star Series 10K - 40Kva |
| Brand Name: | UPSEN |
| Place of Origin: | China (Mainland) |
Quick Details
Specifications
UPS Key Features
1.True double-conversion
2. DSP technology guarantees high performance
3. Output power factor 0.8
4. IGBT inverter and output isolation transformer
5. Active power factor correction in all phases
6. 50Hz/60Hz frequency converter mode
7. ECO mode operation for energy saving
8. Accepts dual-mains inputs
9. Emergency power off function (EPO)
APPLICATIONS:
Medical Equipment,Communications Equipment;Telecommunications
Systems,Electric powered Bicycle and Wheelchairs etc.
Systems,Electric powered Bicycle and Wheelchairs etc.
Technical Specification
| VIEW STAR 3P/3P 10K/15K/20K/30K ONLINE UPS SELECTION GUIDE | |||||
| MODEL | VS33 10K(L) | VS33 15K(L) | VS33 20K(L) | VS33 30K(L) | |
| PHASE | 3 phase in / 3 phase out | ||||
| CAPACITY | 10000VA/8000 W | 15000VA/12000W | 20000VA /16000W | 30000VA/24000W | |
| INPUT | |||||
| Nominal Voltage | 3 x 400 VAC (3Ph+N) | ||||
| Voltage Range |
305-478 VAC (3-phase) @ 100% load 190-520 VAC (3-phase) @ 50% load |
||||
| Frequency Range | 46~54 Hz or 56~64Hz | ||||
| Power Factor | >= 0.99 @ 100% load | ||||
| OUTPUT | |||||
| Output Voltage | 3 x 400 VAC (3Ph+N) | ||||
| AC Voltage Regulation (Batt. Mode) | ± 1% | ||||
| Frequency Range (Synchronized Range) | 46~54Hz or 56~64Hz | ||||
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz | ||||
| Current Crest Ratio | 3:1 (max.) | ||||
| Harmonic Distortion | <= 2 % THD (Linear Load) <= 5 % THD (Non-linear Load) | ||||
| Transfer Time | AC mode to Battery mode | zero | |||
| Inverter to Bypass | zero | ||||
| Waveform (Batt. Mode) | Pure Sine Wave | ||||
| EFFICIENCY | |||||
| AC Mode | 89% | 89% | 89% | 90% | |
| Battery Mode | 86% | 88% | 87% | 89% | |
| BATTERY | |||||
| Standard Model | Battery Type | 12 V / 9 AH | |||
| Numbers | 20 pcs (18 - 20 adjustable) | 20 pcs (18 - 20 adjustable)x 2 strings | 20pcs (18-20adjustable) x 3 strings | ||
| Typical Recharge Time | 9 hours recover to 90% capacity | ||||
| Charging Current (max.) | 1A | 2A | 2A | 4A | |
| Charging Voltage | 273 VDC ± 1%(based on 20 pcs batteries) | ||||
| Long-run Model | Battery Type | Depending on the capacity of external batteries | |||
| Numbers | |||||
| Charging Current (max.) | 4A | 4A | 4A | 12A | |
| Charging Voltage | 273 VDC ± 1%(based on 20 pcs batteries) | ||||
| INDICATORS | |||||
| LCD Panel | UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions | ||||
| ALARM | |||||
| Battery Mode | Sounding every 4 seconds | ||||
| Low Battery | Sounding every second | ||||
| Overload | Sounding twice every second | ||||
| Fault | Continuously sounding | ||||
| PHYSICAL | |||||
| Standard Model | Dimension, D X W X H (mm) | 815 x 250 x 826 | 815 x 250 x 826 | 815 x 250 x 826 | 815 x 300 x 1000 |
| Net Weight (kgs) | 109 | 164 | 164 | 233.5 | |
| Long-run Model | Dimension, D X W X H (mm) | 592 x 250 x 826 | 592 X 250 X 826 | 592 X 250 X 826 | 815 x 250 x 826 |
| Net Weight (kgs) | 38 | 40 | 40 | 64 | |
| ENVIRONMENT | |||||
| Operation Humidity | 0-95 % RH @ 0- 40°C (non-condensing) | ||||
| Noise Level | Less than 60dB @ 1 Meter | Less than 65dB @ 1 Meter | |||
| MANAGEMENT | |||||
| Smart RS-232/USB | Supports Windows? 2000/2003/XP/Vista/2008, Windows? 7/8, Linux, Unix, and MAC | ||||
| Optional SNMP | Power management from SNMP manager and web browser | ||||
* L means long-run model