Product Main

Quick Details

Application: Computer
Type: On-line
Protection: Overcurrent
Phase: Three Phase
Model Number: View Star Series 10K - 40Kva
Brand Name: UPSEN
Place of Origin: China (Mainland)

Specifications

UPS Key Features    
1.True double-conversion
2. DSP technology guarantees high performance
3. Output power factor 0.8
4. IGBT inverter and output isolation transformer
5. Active power factor correction in all phases
6. 50Hz/60Hz frequency converter mode
7. ECO mode operation for energy saving
8. Accepts dual-mains inputs
9. Emergency power off function (EPO)

APPLICATIONS:

Medical Equipment,Communications Equipment;Telecommunications
Systems,
Electric powered Bicycle and Wheelchairs etc.

 

Technical Specification

VIEW STAR 3P/3P 10K/15K/20K/30K ONLINE UPS SELECTION GUIDE
MODEL  VS33 10K(L)  VS33 15K(L) VS33 20K(L) VS33 30K(L)
PHASE 3 phase in / 3 phase out
CAPACITY 10000VA/8000 W 15000VA/12000W 20000VA /16000W 30000VA/24000W
INPUT
Nominal Voltage 3 x 400 VAC (3Ph+N) 
Voltage Range  305-478 VAC (3-phase) @ 100% load
190-520 VAC (3-phase) @ 50% load 
Frequency Range 46~54 Hz or 56~64Hz
Power Factor >= 0.99  @ 100% load
OUTPUT
Output Voltage 3 x 400 VAC (3Ph+N) 
AC Voltage Regulation                (Batt. Mode) ± 1%
Frequency Range              (Synchronized Range) 46~54Hz or 56~64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio 3:1 (max.)
Harmonic Distortion <= 2 % THD (Linear Load)  <= 5 % THD (Non-linear Load)
Transfer Time AC mode to           Battery mode zero
Inverter to Bypass zero
Waveform (Batt. Mode) Pure Sine Wave
EFFICIENCY
AC Mode 89% 89% 89% 90%
Battery Mode 86% 88% 87% 89%
BATTERY
Standard Model Battery Type 12 V / 9 AH
Numbers          20 pcs            (18 - 20 adjustable) 20 pcs (18 - 20 adjustable)x 2 strings      20pcs             (18-20adjustable)      x 3 strings
Typical Recharge Time 9 hours recover to 90% capacity
Charging Current (max.) 1A 2A 2A 4A
Charging Voltage  273 VDC ± 1%(based on 20 pcs batteries)
Long-run Model Battery Type Depending on the capacity of external batteries
Numbers
Charging Current (max.) 4A 4A 4A 12A
Charging Voltage 273 VDC ± 1%(based on 20 pcs batteries)
INDICATORS
LCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
ALARM
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
Overload Sounding twice every second
Fault Continuously sounding
PHYSICAL
Standard Model Dimension,               D X W X H (mm) 815 x 250 x 826 815 x 250 x 826 815 x 250 x 826 815 x 300 x 1000
Net Weight (kgs) 109 164 164 233.5
Long-run Model Dimension,               D X W X H (mm) 592 x 250 x 826 592 X 250 X 826 592 X 250 X 826 815 x 250 x 826
Net Weight (kgs) 38 40 40 64
ENVIRONMENT
Operation Humidity 0-95 % RH @ 0- 40°C (non-condensing)
Noise Level    Less than 60dB     @ 1 Meter Less than 65dB @ 1 Meter
MANAGEMENT
Smart RS-232/USB Supports Windows? 2000/2003/XP/Vista/2008, Windows?  7/8, Linux, Unix, and MAC
Optional SNMP Power management from SNMP manager and web browser

* L means long-run model