After-sales Service Provided: | Engineers available to service machinery overseas |
---|---|
Certification: | CE, ISO9001,CCC |
Weight: | 1050kg |
Dimension(L*W*H): | 1200*950*1500mm |
Power(W): | 55KW |
Voltage: | 380V,50Hz |
Usage: | Transformer Oil |
Model Number: | ZYD-100 |
Brand Name: | Zhongneng |
Place of Origin: | China (Mainland) |
Working Pressure: | 0.4MPa |
Flow: | 100L/min |
Condition: | New |
Type: | Return Filter |
Structure: | Vacuum |
Warranty: | 1 Year |
Color: | Green |
Vacuum Degree: | -0.06~-0.095Mpa |
Breakdown Voltage: | 70KV |
Water Content: | 4PPM(Without Free Carbon) |
Gas Content: | 0.1% |
Acidity: | 0.03mgKOH/g |
Cleanness: | 6 grade( NAS ) |
Quick Details
Specifications
ZYD Vacuum Waste Transformer Oil Refinery Systems/Insulation Oil Recycling Plant/Insulating oil purifier
Application
This machine is applied to treat various of unqualified insulation oils including aging transformer oil specially for
the power which is above 110V,mutual inductor oil, switch oil and so on. Also it can inject the insulating oil into the
transformers on-line. Regenerate the seriously deteriorated oil by removing the polarity materials.
Features
1. PH of treated oil ≥5.5
2. Acid≤0.03mgkoH/g
3. Flash point≥145℃
4. Anti-pressure≥60KV
5. Dielectric loss: tgδ(90℃)%≤0.001
6. High vacuum: High point-Vacuum≤5pa Working-vacuum≤35pa
7. High absorption speed: Absorption speed power≥333L/Sr.
8. Duplex 3D stereo-evaporation, eliminating the liquid water quickly
9. UK G technology by which the trace water that is show chain, such as dissolved water, can be removed effectively.
10. Distinctive removing impurities system filtering through double FH trapezoidal network and absorbing by high polymer
without the mechanical power.
11. Carbon fiber infrared heating system that can make the oil contains zero sum of ethyne after the treatment
12. Specially applied to vacuum oiling and drying for power transmission equipments that are over 110KV
13. The oil of any grades can be treated on line at the working site.
Advantages:
BesidesDouble-Stage High-Efficiency Vacuum Insulation Oil purifier's function of dewatering, degassing and eliminating impurities, this machine can regenerate the seriously deteriorated oil by removing the polarity materials, such as the deep oxides, free carbon in the oil effectively. It can make the seriously deteriorated oil reach to the normal index like anti-oxides, acid- alkali water-solubility.
Technical Data
Parameters |
Unit |
ZYD-30 |
ZYD-50 |
ZYD-100 |
ZYD-150 |
ZYD-200 |
ZYD-250 |
ZYD-300 |
|
Flow |
L/H |
1800 |
3000 |
6000 |
9000 |
12000 |
15000 |
18000 |
|
Working vacuum |
MPa |
-0.08 ~ -0.099 |
|||||||
Working Pressure |
MPa |
≤0.2 |
|||||||
Temperature Range |
℃ |
20 ~ 80 |
|||||||
Power |
|
Three Phase 50Hz380V (according customer requirement) |
|||||||
Working Noise |
dB(A) |
75 |
75 |
75 |
80 |
80 |
80 |
80 |
|
Heating Power |
KW |
27 |
30 |
45 |
60 |
75 |
90 |
120 |
|
Total Power |
KW |
30 |
37.5 |
52.5 |
71.4 |
86.5 |
102.5 |
135 |
|
Inlet/Outlet |
mm |
φ25 |
φ32 |
φ42 |
φ50 |
φ50 |
φ60 |
φ60 |
|
Weight |
Kg |
450 |
700 |
1050 |
1400 |
1800 |
2000 |
2200 |
|
Overall Dimension |
Length |
mm |
1250 |
1400 |
1640 |
1800 |
2000 |
2050 |
2500 |
Width |
mm |
900 |
1050 |
1200 |
1350 |
1450 |
1500 |
1800 |
|
Height |
mm |
1700 |
1990 |
2000 |
2000 |
2100 |
2100 |
2400 |
Oil Data after Treatment
Moisture (water content) |
≤ 3 PPM |
Gas Content |
≤0.1% |
Impurities Degree (Filtration precision) |
≤1u (without free carbon) |
Breakdown Voltage (Dielectric) |
≥80 KV |
PH value |
≥5.5 |
Acid Value |
≤0.03 mg koH/g |
Dielectric Loss Factors |
tgδ (90℃) % ≤0.001 |
Cleanliness |
≤NAS 1638 Grade 6 |